Plan Review Stops For Permit 11010719 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-02-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-02-24 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-02-24 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-02-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-02-11 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-02-11 |
Time |
09:27 |
Sent To |
E |
|
Notes |
2011-02-11 11:44:20 | 2007 FBC W/2009 REVISIONS | | | | 1) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE | | 2007 FBC EXISTING BUILDING CODE. APPEARS TO BE A LEVEL | | 3 ALTERATION. | | | | 2) SPECIFY THE DESIGN CRITERIA ON THE PLANS. THIS | | INCLUDES THE BASIC WINDSPEED, EXPOSURE CATEGORY AND | | COMPONENT AND CLADDING PRESSURES FOR THE WINDOWS AND | | DOORS, | | | | 3) ASTM C 926 REQUIRES 7/8" THICK STUCCO APPLIED IN | | THREE-COATS WHEN APPLIED VERTICALLY TO A METAL LATH | | OVER A SOLID BASE. PLEASE CORRECT. | | | | 4) FBC R703.2 REQUIRES A WATER-RESISTIVE BARRIER TO BE | | APPLIED OVER SHEATHING ON EXTERIOR WALLS. SHOW | | COMPLIANCE. | | | | 5) SHOW COMPLIANCE WITH FBC R703.6.3 FOR THE REQUIRED | | BOND BREAK BETWEEN THE STUCCO AND THE WATER-RESISTIVE | | BARRIER. | | | | 6) PRODUCT APPROVALS WERE SUBMITTED FOR A NON-IMPACT | | RATED OUT SWING GLAZED DOOR. FBC R301.2.1.2 REQUIRES | | GLAZED OPENINGS TO BE PROTECTED FROM WIND-BORNE DEBRIS. | | SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR STORM | | PANELS. SPECIFY THE MOUNTING METHOD, ANCHOR TYPE AND | | ANCHOR SPACING THAT WILL BE USED. | | | | 7) THE PLANS WILL BE REQUIRED TO BE REVIEWED BY PALM | | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. | | THE STAMPED PLANS AND A COPY OF THE PAID RECEIPT ARE | | REQUIRED TO BE SUBMITTED TO THE CITY CONSTRUCTION | | SERVICES DEPARTMENT BEFORE THE PERMIT IS ISSUED. | | | | 8) SPECIFY HOW THE 2 X 4 PT TOP PLATE WILL BE ATTACHED | | TO THE CONCRETE BEAM IN WALL SECTION A. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-02-23 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-23 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-23 |
Time |
14:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2011-02-11 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-11 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-11 |
Time |
15:09 |
Sent To |
|
|
Notes |
2011-02-11 15:27:57 | PROVIDE ELECTRICAL PLAN AND PERMIT. SHOW LOCATION AND | | SIZE OF EXISTING CIRCUITS AND PANELBOARD. | | PROVIDE ELECTRICAL RECEPTACLES AS REQUIRED. NEC 210.52, | | 406.11 | | PROVIDE GFCI PROTECTION AS REQUIRED. NEC 210.8 | | PROVIDE LIGHTING OUTLETS AS REQUIRED. NEC 210.70 | | | | ROBERT LECKY, ELECTRICAL PLAN REVIEW, 561-805-6718 | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2011-02-24 |
|
|
Cont ID |
|
Sent By |
jpapa |
Date |
2011-02-24 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2011-02-24 |
Time |
10:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2011-02-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2011-02-02 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2011-01-31 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-02-22 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-02-22 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-02-22 |
Time |
16:18 |
Sent To |
|
|
Notes |
2011-02-22 16:19:04 | GAVE TO LECKY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-02-22 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-02-11 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-02-02 |
Time |
15:27 |
Sent To |
|
|
Notes |
2011-02-02 15:30:36 | SENT TO R13. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
P |
Date |
2011-02-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-02-25 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-02-25 |
Time |
12:55 |
Sent To |
|
|
Notes |
2011-02-25 12:57:23 | NO FEES DUE. SEE STAMPED PLANS BY MAB. DATED 2/25/11. | 2011-02-24 08:53:32 | NEEDS REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2011-02-24 |
|
|
Cont ID |
|
Sent By |
jpapa |
Date |
2011-02-24 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2011-02-24 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2011-02-02 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2011-02-02 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jpapa |
Date |
2011-02-24 |
Time |
10:27 |
Sent To |
|
|
Notes |
2011-02-02 13:59:07 | OWNER TO SUBMIT TWO SURVEYS FOR RECORDS. |
|
|