Plan Review Details - Permit 11010332
Plan Review Stops For Permit 11010332
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-03-23 Cont ID  
Sent By rregueir Date 2011-03-23 Time 14:40 Rev Time 0.00
Received By rregueir Date 2011-03-23 Time 14:40 Sent To  
Notes
2011-03-23 14:43:50OK PER JW. CONTRACTOR HAS SIGNED ON TO THE
 PERMIAPPLICATION. SEE PREVIOUS BUILDING REVIEW NOTES
 FOR PROVISO CONDITIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-01-20 Cont ID  
Sent By jwitmer Date 2011-01-20 Time 08:01 Rev Time 0.55
Received By jwitmer Date 2011-01-19 Time 15:42 Sent To  
Notes
2011-01-20 08:00:50BUILDING PLAN REVIEW
 PERMIT: 11010332
 ADD: 525 OKEECHOBEE BLVD. # 1140
 CONT: TO BE DETERMINED
 TEL: (561)###-####
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS APPEAR TO BE CODE COMPLIANT, WILL REMAIN IN
 FAILED STATUS UNTIL CONTRACTOR IS SIGNED ONTO THE
 PERMIT AND LICENSURE CAN BE VERIFIED.
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
 2007/ 2009 FBC-BUILDING 11-4.22.1(1) ALL DOORS TO
 ACCESSIBLE TOILET ROOMS SHALL COMPLY WITH SECTION
 11-4.13. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACE REQUIRED FOR ANY FIXTURE.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-01-21 Cont ID  
Sent By rlecky Date 2011-01-21 Time 13:52 Rev Time 0.00
Received By rlecky Date 2011-01-21 Time 13:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-01-26 Cont ID  
Sent By mcarsill Date 2011-01-26 Time 12:45 Rev Time 0.00
Received By mcarsill Date 2011-01-26 Time 12:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-23 Cont ID  
Sent By rregueir Date 2011-03-23 Time 14:23 Rev Time 0.00
Received By rregueir Date 2011-01-31 Time 08:56 Sent To  
Notes
2011-01-31 08:57:20**DIGITAL PLANS** SEE PROJECTDOX
  
 PLANS REMOVED AND REPLACED. REDISTRIBUTED ON 1/25

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-01-28 Cont ID  
Sent By rregueir Date 2011-01-28 Time 16:34 Rev Time 0.00
Received By rregueir Date 2011-01-28 Time 16:32 Sent To  
Notes
2011-01-28 16:33:59**PROVISO**
 PAGE P1.01 CALLS FOR NEW VENT PIPE TO BE INSTALLED AND
 MADE OF PVC. THIS SPACE IS SERVED BY A RETURN AIR
 PLENUM. COMBUSTIBLE MATERIALS (SUCH AS PVC) ARE
 PROHIBITED IN PLENUMS PER FBC-M 602.2.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-03-23 Cont ID  
Sent By lwagner Date 2011-03-23 Time 09:36 Rev Time 0.00
Received By lwagner Date 2011-03-23 Time 09:36 Sent To  
Notes
2011-03-23 09:37:39NO PVC IN PLENUMN

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2011-03-25 Cont ID  
Sent By rregueir Date 2011-03-25 Time 08:29 Rev Time 0.00
Received By rregueir Date 2011-03-25 Time 08:29 Sent To  
Notes
2011-03-25 08:30:31PEDDS SIGNATURE DOCUMENTS RECEIVED