Plan Review Details - Permit 11010289
Plan Review Stops For Permit 11010289
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-02-07 Cont ID  
Sent By jwitmer Date 2011-02-07 Time 12:35 Rev Time 0.50
Received By jwitmer Date 2011-02-07 Time 12:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-01-24 Cont ID  
Sent By jwitmer Date 2011-01-24 Time 12:55 Rev Time 0.75
Received By jwitmer Date 2011-01-24 Time 09:14 Sent To  
Notes
2011-01-24 12:55:08BUILDING PLAN REVIEW
 PERMIT: 11010289
 ADD: 400 COLUMBIA DRIVE
 CONT: AUTO BUILDERS
 TEL: (561)722-3956
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) 2007 EXISTING BUIULDING CODE: 101.3 INTENT. THE
 INTENT OF THIS CODE IS TO PROVIDE FLEXIBILITY TO PERMIT
 THE USE OF ALTERNATIVE APPROACHES TO ACHIEVE COMPLIANCE
 WITH MINIMUM REQUIREMENTS TO SAFEGUARD THE PUBLIC
 HEALTH, SAFETY AND WELFARE INSOFAR AS THEY ARE AFFECTED
 BY THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY,
 ADDITION AND RELOCATION OF EXISTING BUILDINGS.
  
 1A) PLEASE PROVIDE A KEY PLAN OF THE ENTIRE BUILDING
 PROVIDING THE ADDRESS (SUITE NUMBER) FOR EACH TENANT
 SPACE, PLEASE INCLUDE THE
 FUTURE TENANT SPACE BEING CREATED.
  
 1B) PLEASE FILLOUT A SECOND PERMIT APPLICATION FOR THE
 NEWLY CREATED FUTURE TENANT SPACE, BACK OUT 1/2 OF THE
 COST FOR THE TENANT SEPERATION WALL AND APPLY TO THIS
 NEW PERMIT. A NON-CONFORMITY IS BEING CREATED (
 NO-RESTROOMS) WITHIN THE FUTURE TENANT SPACE.
 WE WILL BE CREATING A CHANGE IN OCCUPANCY FOR THIS
 SPACE, TO A SHELL ONLY ! FUTURE TENANT WILL NEED TO
 INSTALL RESTROOMS FOR A HABITABLE SPACE.
  
 1C) WITHIN THE FUTURE TENANT SPACE PLEASE BACK OUT THE
 ELECTRICAL FROM THE ORIGINAL PERMIT SINCE THIS WORK
 WILL ALSO NEED TO BE REFLECTED
 UNDER THE FUTURE TENANT PERMIT.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-01-19 Cont ID  
Sent By rlecky Date 2011-01-19 Time 12:48 Rev Time 0.00
Received By rlecky Date 2011-01-19 Time 11:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-01-25 Cont ID  
Sent By wjolin Date 2011-01-25 Time 12:43 Rev Time 0.00
Received By wjolin Date 2011-01-25 Time 12:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-13 Cont ID  
Sent By jwitmer Date 2011-01-13 Time 11:19 Rev Time 0.00
Received By jwitmer Date 2011-01-13 Time 11:19 Sent To  
Notes
2011-01-13 11:20:44INCOMING SENT TO C-3. JW

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-01-25 Cont ID  
Sent By hmoser Date 2011-01-25 Time 08:11 Rev Time 0.00
Received By hmoser Date 2011-01-25 Time 08:11 Sent To  
Notes
2011-01-25 08:15:37PASS PROVISO
 PLEASE REFER TO SECTION 407 2007 FBC (M) RETURN AIR
 INTAKE FOR ROOMS 119 AND 120
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status N Date 2011-02-07 Cont ID  
Sent By lwagner Date 2011-02-07 Time 12:44 Rev Time 0.00
Received By lwagner Date 2011-02-07 Time 12:44 Sent To  
Notes
2011-02-07 12:45:19NO PLUMBING WORK AT THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-01-24 Cont ID  
Sent By lwagner Date 2011-01-24 Time 09:42 Rev Time 0.00
Received By lwagner Date 2011-01-24 Time 09:42 Sent To  
Notes
2011-01-24 09:46:26FBC PLUMBING 2007 PLAN REVIEW #1
 DENIED:
  
 PLEASE SEE NOTES IN BUILDING REVIEW CONCERNING THE
 FUTURE TENANT SPACE.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2011-01-28 Cont ID  
Sent By lfranco Date 2011-01-28 Time 14:30 Rev Time 0.00
Received By lfranco Date 2011-01-28 Time 14:30 Sent To  
Notes
2011-01-28 14:31:12PLANNING AND ZONING: *** ZONING REVIEW NOT REQUIRED:
 INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES
 NOT EXCEED 50% OF THE IMPROVEMENT VALUE. ****