Plan Review Details - Permit 11010168
Plan Review Stops For Permit 11010168
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-01-20 Cont ID  
Sent By jwitmer Date 2011-01-20 Time 13:54 Rev Time 1.00
Received By jwitmer Date 2011-01-20 Time 13:53 Sent To  
Notes
2011-01-20 13:54:30BUILDING PLAN REVIEW
 PERMIT: 11010168
 ADD: 1601 FORUM PL# 1202
 CONT: ANDERSON-MOORE CONSTRUCTION CORP
 TEL: (561)662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 2007/ 2009 EXISTING BUILDING CODE: LEVEL II. 706.1 A
 BUILDING, STRUCTURE OR FACILITY THAT IS ALTERED SHALL
 COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING.
  
 2007/ 2009 FBC-BUILDING SECTION 11-4.1.6(2) ALTERATIONS
 MADE TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO ALTERED
 AREAS SHALL BE DEEMED DISPROPORTIONATE TO THE OVERALL
 ALTERATION WHEN THE COST EXCEEDS 20 PERCENT OF THE COST
 OF THE ALTERATION TO THE PRIMARY FUNCTION AREA.
  
 2007/2009 FBC-BUILDING SECTION 11-4.1.6(2)(2)(A) IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER:
 (I) AN ACCESSIBLE ENTRANCE;
 (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA:
  
 PLEASE SEE DOORS MARKED WITH (***) 2007/ 2009 FBC-B
 SECTION 11-4.13.6 MANEUVERING CLEARENCES AT DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS THAT ARE NOT
 AUTOMATIC OR POWER-ASSISTED SHALL BE AS SHOWN IN FIG.
 25. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED
 CLEARANCES SHALL BE CLEAR & LEVEL.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-01-20 Cont ID  
Sent By rlecky Date 2011-01-20 Time 08:56 Rev Time 0.00
Received By rlecky Date 2011-01-19 Time 15:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-01-24 Cont ID  
Sent By ddaniels Date 2011-01-24 Time 16:49 Rev Time 0.00
Received By ddaniels Date 2011-01-24 Time 16:49 Sent To M
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-01-13 Cont ID  
Sent By wjolin Date 2011-01-13 Time 13:38 Rev Time 0.00
Received By wjolin Date 2011-01-13 Time 13:27 Sent To  
Notes
2011-01-13 13:38:331601 FORUM PLACE, SUITE #1202
 PERMIT #11010168
 REVIEW COMMENTS - FIRE
  
 THE COMBINED OCCUPANT LOAD IS SHOWN AS 69 OCCUPANTS;
 DOORS ARE REQUIRED TO SWING IN THE DIRECTION OF EGRESS
 TRAVEL FOR AN OCCUPANT LOAD OF 50 OR GREATER PERSONS
 PER SECTION 7.2.1.4.2 OF THE FLORIDA FIRE PREVENTION
 CODE (NFPA 101 - LIFE SAFETY CODE).
  
 EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER???PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 WIDTH. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER. (REFERENCE: SECTION 8.3.2.4 OF FLORIDA
 FIRE PREVENTION CODE ??? NFPA 101)
  
 PROVIDE NEW AND EXISTING DOOR HARDWARE/SECURITY
 INFORMATION ON PLANS.
  
 PROVIDE VISUAL NOTIFICATION APPLIANCE IN CONFERENCE
 ROOM 101.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-27 Cont ID  
Sent By lmartine Date 2011-01-27 Time 09:36 Rev Time 0.00
Received By lmartine Date 2011-01-12 Time 14:11 Sent To  
Notes
2011-01-12 14:19:51SENT TO B9.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-01-25 Cont ID  
Sent By hmoser Date 2011-01-25 Time 14:54 Rev Time 0.00
Received By hmoser Date 2011-01-25 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-01-27 Cont ID  
Sent By lwagner Date 2011-01-27 Time 09:35 Rev Time 0.00
Received By lwagner Date 2011-01-27 Time 09:20 Sent To  
Notes
***NONE***