Plan Review Details - Permit 10120607
Plan Review Stops For Permit 10120607
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-02-15 Cont ID  
Sent By shill Date 2011-02-15 Time 13:26 Rev Time 0.00
Received By shill Date 2011-02-15 Time 13:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-01-06 Cont ID  
Sent By shill Date 2011-01-06 Time 11:49 Rev Time 0.00
Received By shill Date 2011-01-06 Time 11:49 Sent To  
Notes
2011-01-06 12:22:36****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. THE IBHS IS FOR USE IN EXPOSURE B, SEE FBC R
 301.2.1.1(5). THIS PARCEL IS LOCATED IN EXPOSURE C, SEE
 DEFINITION OF EXPOSURE C. USE OF REDUCED PRESSURES IN
 THE TRANSITION ZONE MUST BE CALCULATED BY AN ENGINEER.
 DUE TO THE PROXIMITY OF THIS PARCEL TO THE
 INTRACOASTAL, SURFACE ROUGHNESS B DOES NOT PREVAIL FOR
 1500 FEET IN ALL DIRECTIONS.
  
 2. PROVIDE THE PRINTED NAME OF THE INDIVIDUAL TAKING
 RESPONSIBILITY FOR THE DESIGN AS WELL AS THAT
 INDIVIDUAL'S LICENSE NUMBER. FLORIDA STATUTE 471, FS
 481, FS 489.
  
 3. IF A PRESCRIPTIVE METHOD IS USED FOR THE DESIGN,
 PROVIDE PAGE NUMBERS OR TABLE NUMBERS FOR ALL DETAILS
 AND VALUES. FOR SINTANCE, "FRONT PORCH DETAIL," NO
 REFERENCE PROVIDED FOR THE FOOTINGS OR FOR THE MASONRY
 DESIGN.
  
 4. PROVIDE THE IMPACT FEE RECEIPT. THE PLANS HAVE BEEN
 STAMPED BUT A RECEIPT SHOWING THAT FEES WERE PAID WITH
 A BALANCE DUE OF "$0" IS REQUIRED.
  
 5. PLANS ARE TO BE ARCHITECTURAL QUALITY, TO SCALE,
 SHOWING ALL APPLICABLE DETAILS.
  
 6. THIS PLAN INVOLVES REMOVAL OF AN EXTERIOR WALL. HOW
 HAS IT BEEN DETERMINED THAT THIS WALL IS NOT LOAD
 BEARING? ADDITIONAL INFORMATION/EVALUATION REQUIRED.
  
 7. BOND BREAK REQUIRED, FBC R 703.6.3. REVISE ALL
 APPLICABLE DETAILS.
  
 8. REVISE DETAILS TO SHOW COMPLIANCE WITH FBC R 704.1,
 INSPECTION FOR TERMITES.
  
 9. ENERGY CALCS REQUIRED, FBC R 1100.
  
 10. PLANS ARE TO BE ARCHITECTURAL QUALITY, TO SCALE.
 EVERY DETAIL OR SECTION ON THE PLAN SHOULD BE LABELED
 WITH CORRESPONDING DETAIL MARKERS ON THE FLOOR PLAN.
  
 11. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
  
 12. PROVIDE A SOILS INVESTIGATION REPORT, FBC R401.4.
  
 13. THIS PARCEL IS LOCATED IN A HIGH HAZARD FLOOD ZONE.
 PROVIDE AN ELEVATION CERTIFICATE AND INCLUDE PROPOSED
 ELEVATION ON THE PLAN. ELEVATION IS TO BE A MINIMUM OF
 6" ABOVE BFE, CITY OF WEST PALM BEACH MUNICIPAL CODE
 94-546(B)*
  
 14. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 FOR COMPONENTS & CLADDING, FAC9B72.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-02-16 Cont ID  
Sent By rlecky Date 2011-02-16 Time 16:41 Rev Time 0.00
Received By rlecky Date 2011-02-16 Time 16:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-01-07 Cont ID  
Sent By rlecky Date 2011-01-07 Time 11:03 Rev Time 0.00
Received By rlecky Date 2011-01-07 Time 10:29 Sent To  
Notes
2011-01-07 11:13:39GFCI RECEPTACLE REQUIRED OUTSIDE AT THE ENTRANCE AREA
 AND IN THE GARAGE. NEC 210.52
 GFCI PROTECTION REQUIRED FOR COUNTER TOP RECEPTACLES.
 NEC 210.8, 210.52
 GFCI PROTECTED RECEPTACLE REQUIRED AT MECHANICAL
 EQUIPMENT. NEC 210.63
 ALL NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC
 406.11
 THE SMOKE DETECTORS MUST BE INTERCONNECTED. FBC R313.2
 BEDROOM RECEPTACLES MUST BE PROTECTED WITH AFCI'S. NEC
 210.12
 PROVIDE A BONDING BAR AT THE SERVICE. NEC 250.94
 LOCATE ON THE PLAN THE OUTDOOR MECHANICAL EQUIPMENT.
 VERIFY ALL OUTDOOR EQUIPMENT IS ABOVE THE MINIMUM FLOOD
 ELEVATION.
  
 ROBERT LECKY, ELECTRICAL PLANS REVIEW, 561-805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-02-17 Cont ID  
Sent By rmcdouga Date 2011-02-17 Time 13:32 Rev Time 0.00
Received By rmcdouga Date 2011-02-14 Time 10:38 Sent To  
Notes
2011-02-14 10:39:37****EXPEDITED****
 R25
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-07 Cont ID  
Sent By shill Date 2011-01-07 Time 10:38 Rev Time 0.00
Received By shill Date 2010-12-28 Time 12:46 Sent To  
Notes
2010-12-28 12:49:19R--11
 ***************EXPEDITED*****************

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-02-15 Cont ID  
Sent By shill Date 2011-02-15 Time 13:26 Rev Time 0.00
Received By shill Date 2011-02-15 Time 13:26 Sent To  
Notes
2011-02-15 13:28:02MU 2010 023300

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-01-06 Cont ID  
Sent By shill Date 2011-01-06 Time 12:33 Rev Time 0.00
Received By shill Date 2011-01-06 Time 12:33 Sent To  
Notes
2011-01-06 12:34:03PROVIDE IMPACT FEE RECEIPT.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-02-17 Cont ID  
Sent By rmcdouga Date 2011-02-17 Time 13:31 Rev Time 0.00
Received By rmcdouga Date 2011-02-17 Time 13:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-01-07 Cont ID  
Sent By rmcdouga Date 2011-01-07 Time 13:24 Rev Time 0.00
Received By rmcdouga Date 2011-01-07 Time 13:23 Sent To  
Notes
2011-01-07 14:08:58PLUMBING DENIED
  
 1) THE NAME AND LICENSE NUMBER OF THE PERSON
 RESPONSIBLE FOR THE PLUMBING SYSTEM DESIGN IS REQUIRED
 ON THE DRAWING. THE PLUMBING SYSTEM CAN BE DESIGNED BY
 A FLORIDA LICENSED PLUMBING CONTRACTOR, ENGINEER OR
 ARCHITECT. FS 471 AND 481.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2011-02-17 Cont ID  
Sent By eschneid Date 2011-02-17 Time 15:23 Rev Time 0.00
Received By eschneid Date 2011-02-17 Time 15:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2011-01-03 Cont ID  
Sent By eschneid Date 2011-01-03 Time 15:09 Rev Time 0.50
Received By eschneid Date 2011-01-03 Time 15:09 Sent To  
Notes
2011-01-03 15:16:09FAILED
  
 1) DUE TO THE NEW SLABS THAT ARE BEING POURED ZONING
 WILL NEED TO VERIFY SETBACKS. PROVIDE A SURVEY, LESS
 THAN ONE YEAR OLD,SHOWING FRONT AND REAR SETBACK
 DIMENSIONS.
  
 2) THE NEW SLAB OFF THE REAR OF THE HOUSE IS CONSIDERED
 A STEP/PORCH AND THUS MAY BE NO CLOSER THAN TWO (2)
 FEET FROM THE REAR PROPERTY LINE.
  
 3) THE NEW SLABS IN THE FRONT OF THE HOUSE MAY NOT
 DECREASE THE FRONT YARD OPEN SPACE LESS THAN 1,000
 SQUARE FEET.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.