Plan Review Details - Permit 10120524
Plan Review Stops For Permit 10120524 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2011-01-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-01-05 |
Time |
13:40 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2011-01-05 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2011-01-04 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-01-04 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-01-03 |
Time |
16:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2010-12-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-12-29 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-12-29 |
Time |
11:32 |
Sent To |
|
|
Notes |
2010-12-29 11:48:33 | 2465 MERCER AVENUE | | PERMIT NUMBER 10120524 | | "COMMERCIAL CONSTRUCT INTERIOR IMPROVEMENTS" | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | WITH NFPA 241. | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | SPRINKLER AND FIRE ALARM REMODELING. | | | | 3. NEW HYDRAULIC CALCULATIONS ARE TO BE SUBMITTED WITH | | THE FIRE SPRINKLER DRAWINGS SINCE FLEX HEADS ARE | | PLANNED TO BE USED. | | | | 4. NEW TENANT DEMISING WALLS ARE TO BE PROPERLY | | IDENTIFIED AND LABELED AND ALL PENETRATIONS ARE TO BE | | PROPERLY SEALED. | | | | 5. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATION. | | | | 6. ACCESS TO A PROPERLY SERVICE TAGGED AND RATED FIRE | | EXTINGUISHER SHALL NOT EXCEED 75 FEET OF TRAVEL | | DISTANCE. | | | | | | APPROVED PROVISO | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-01-26 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-01-26 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-01-26 |
Time |
14:36 |
Sent To |
|
|
Notes |
2011-01-26 14:38:09 | IN PLUMBING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-01-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-01-11 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-12-22 |
Time |
09:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2011-01-31 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-01-31 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-01-31 |
Time |
12:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2011-01-11 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-01-28 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-01-11 |
Time |
08:36 |
Sent To |
|
|
Notes |
2011-01-11 08:38:27 | PASS PROVISO | | FRESH AIR TO BE METAL DUCT . | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2011-01-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-01-28 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-01-28 |
Time |
15:23 |
Sent To |
M |
|
Notes |
2011-01-28 15:32:51 | MECH NEEDS TO RESTAMP NEW A-3 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-12-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-12-28 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-12-28 |
Time |
10:27 |
Sent To |
|
|
Notes |
2010-12-28 10:42:34 | FBC PLUMBING 2007 REVIEW #1 | | DENIED: | | | | 1. KITCHEN SINK IS NOT PERMITTED IN WET VENT FOR | | RESTROOM 909.1 - THE SINK SHALL DISCHARGE DOWNSTREAM OF | | THE WET VENTED FIXTURES. | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2011-01-13 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-01-13 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-01-13 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
|