Plan Review Details - Permit 10120402
Plan Review Stops For Permit 10120402 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-12-23 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-12-28 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-12-23 |
Time |
15:55 |
Sent To |
|
|
Notes |
2010-12-23 15:56:51 | PER WESLEY JOLIN- PASS PLAN SINCE AS-BUILT PLANS ARE | | EXPECTED. | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-12-21 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-12-21 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-12-21 |
Time |
14:52 |
Sent To |
M |
|
Notes |
2010-12-21 17:34:35 | 700 SOUTH ROSEMARY AVENUE, SUITE #204 | | PERMIT #10120402 | | MASTER #10090192 | | REVIEW COMMENTS - FIRE | | | | | | PROVIDE HYDRAULIC CALCULATIONS SUPPORTING USE OF | | FLEXIBLE SPRINKLER DROPS. | | | | INDICATE THE MAXIMUM NUMBER OF BENDS AND THE MINIMUM | | BEND RADIUS OF THE FLEXIBLE DROPS. | | | | SIDEWALL SPRINKLERS ARE PENETRATING A 2-HOUR FIRE RATED | | PARTITION WALL IN CABANA SEATING #107. VERIFY | | SEMI-RECESSED SIDEWALL SPRINKLERS ARE UL LISTED TO BE | | LOCATED IN A FIRE RATED WALL ASSEMBLY. | | | | INDICATE IF SPRINKLER PROTECTION WILL BE PROVIDED IN | | THE CONCEALED SPACES BELOW THE RAISED PLATFORMS. | | | | INDICATE THE LOCATION OF THE SHUTOFF VALVE CONTROLLING | | THE SPRINKLERS IN THIS SPACE. | | | | A SIDEWALL SPRINKLER INSTALLED BELOW THE TIKI CANOPY IS | | LOCATED 14 FEET FROM THE WALL. | | | | DECORATE COLUMN PALM LEAVES (X4) APPEAR TO CREATE A | | SPRINKLER SPRAY OBSTRUCTION IN THE MAIN DANCE FLOOR | | AREA. | | | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-12-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-12-28 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-12-15 |
Time |
15:28 |
Sent To |
FIRE |
|
Notes |
2010-12-15 16:23:34 | IN FIRE BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-12-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-12-28 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-12-28 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
|