Plan Review Stops For Permit 10120173 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-02-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-07 |
Time |
10:45 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-02-07 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-12-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-12-14 |
Time |
08:57 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-12-14 |
Time |
08:46 |
Sent To |
|
|
Notes |
2010-12-14 08:57:19 | BUILDING PLAN REVIEW | | PERMIT: 10120173 | | ADD: 5200 N FLAGLER #2502& 2503 | | CONT: A&A DEVELOPMENT GROUP LLC | | TEL: (561)719-0895 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE | | TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS | | (CONDOMINIUM SUITES) WHICH COMBINE TO FORM 'THE SITE'. | | A 'UNITY OF TITLE' SHALL BE RECORDED AT THE COUNTY | | COURTHOUSE. SUBMIT A COPY OF THE RECORDED 'UNITY OF OF | | TITLE' DOCUMENT SO THAT FBC TABLE 601 BOUNDARY LINE | | REQUIREMENTS MAY BE DEEMED NOT APPLICABLE. | | | | 2) MASTER BATH SHOWER TENANT SEPERATION WALLS. FBC-B | | 1207.2 AIR BORNE SOUND REQUIREMENTS. | | | | 3) THIS IS ONLY IF ADDITIONAL FLOORING IS TO BE | | APPLIED. FBC-B 1207.3 STRUCTURE BORNE SOUND | | REQUIREMENTS, MUST MEET THE SOUND INSULATION OF 50 STC. | | | | 4) MASTER BATH SHOWER TO MEET THE REQUIREMENTS OF FBC-B | | 2509.2 BASE FOR TILE: SHOWER, EITHER CEMENT, | | FIBER-CEMENT, OR GLASS MAT GYPSUM AS A BACKING BOARD. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-02-11 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-11 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-11 |
Time |
09:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2011-01-04 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2010-12-17 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2010-12-15 |
Time |
09:36 |
Sent To |
|
|
Notes |
2010-12-15 14:06:19 | VERIFY IN WRITING THAT THE MAIN ELECTRICAL SERVICE WILL | | CARRY THE ADDITIONAL ELECTRICAL LOAD CREATED BY ADDING | | TANKLESS WATER HEATER IN UNIT 2502. THE MAIN ELECTRIC | | SERVICE DEMAND MUST BE SIZED FOR THE INCREASED LOAD. | | THE ELECTRIC UTILITY NEEDS TO VERIFY THE INCOMING | | SERVICE AND TRANSFORMER HAVE THE CAPACITY TO HANDLE | | TANKLESS WATER HEATING AS A STANDARD RETO FIT FOR THIS | | BUILDING. | | | | ROBERT LECKY, PLANS EXAMINER 561 805-6718 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2011-02-15 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-02-15 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-02-15 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-12-17 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-12-17 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-12-17 |
Time |
10:28 |
Sent To |
|
|
Notes |
2010-12-17 11:50:32 | 5200 NORTH FLAGLER DRIVE, #2502 & #2503 | | PERMIT #10120173 | | REVIEW COMMENTS - FIRE | | | | | | DOORS THAT OPEN (EXISTING ENTRANCE DOORS) ONTO EXIT | | ACCESS CORRIDORS SHALL HAVE NOT LESS THAN A 20-MINUTE | | FIRE PROTECTION RATING AND SHALL BE SELF-CLOSING AND | | SELF-LATCHING. | | | | REMOVE NON-FUNCTIONING ENTRANCE DOOR (UNIT 2502) TO | | AVOID CONFUSION FOR EMERGENCY RESPONDERS TRYING TO GAIN | | ACCESS TO THE UNIT. | | | | THE HARD-WIRED SMOKE ALARMS SHALL SOUND ONLY WITHIN THE | | DWELLING UNIT; SMOKE ALARMS SHALL NOT BE TIED INTO THE | | BUILDING FIRE ALARM SYSTEM. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-02-01 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-02-01 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-02-01 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-01-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-01-04 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-12-09 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2011-01-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-01-04 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-01-04 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-12-14 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-12-14 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-12-14 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2010-12-30 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-12-30 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-12-30 |
Time |
11:33 |
Sent To |
|
|
Notes |
2010-12-30 11:34:54 | PLANNING AND ZONING: **** *ZONING REVIEW NOT REQUIRED: | | INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES | | NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** |
|
|