Plan Review Details - Permit 10120173
Plan Review Stops For Permit 10120173
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-02-07 Cont ID  
Sent By jwitmer Date 2011-02-07 Time 10:45 Rev Time 0.77
Received By jwitmer Date 2011-02-07 Time 10:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-12-14 Cont ID  
Sent By jwitmer Date 2010-12-14 Time 08:57 Rev Time 0.77
Received By jwitmer Date 2010-12-14 Time 08:46 Sent To  
Notes
2010-12-14 08:57:19BUILDING PLAN REVIEW
 PERMIT: 10120173
 ADD: 5200 N FLAGLER #2502& 2503
 CONT: A&A DEVELOPMENT GROUP LLC
 TEL: (561)719-0895
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS
 (CONDOMINIUM SUITES) WHICH COMBINE TO FORM 'THE SITE'.
 A 'UNITY OF TITLE' SHALL BE RECORDED AT THE COUNTY
 COURTHOUSE. SUBMIT A COPY OF THE RECORDED 'UNITY OF OF
 TITLE' DOCUMENT SO THAT FBC TABLE 601 BOUNDARY LINE
 REQUIREMENTS MAY BE DEEMED NOT APPLICABLE.
  
 2) MASTER BATH SHOWER TENANT SEPERATION WALLS. FBC-B
 1207.2 AIR BORNE SOUND REQUIREMENTS.
  
 3) THIS IS ONLY IF ADDITIONAL FLOORING IS TO BE
 APPLIED. FBC-B 1207.3 STRUCTURE BORNE SOUND
 REQUIREMENTS, MUST MEET THE SOUND INSULATION OF 50 STC.
  
 4) MASTER BATH SHOWER TO MEET THE REQUIREMENTS OF FBC-B
 2509.2 BASE FOR TILE: SHOWER, EITHER CEMENT,
 FIBER-CEMENT, OR GLASS MAT GYPSUM AS A BACKING BOARD.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-02-11 Cont ID  
Sent By rlecky Date 2011-02-11 Time 09:56 Rev Time 0.00
Received By rlecky Date 2011-02-11 Time 09:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-01-04 Cont ID  
Sent By rlecky Date 2010-12-17 Time 14:56 Rev Time 0.00
Received By rlecky Date 2010-12-15 Time 09:36 Sent To  
Notes
2010-12-15 14:06:19VERIFY IN WRITING THAT THE MAIN ELECTRICAL SERVICE WILL
 CARRY THE ADDITIONAL ELECTRICAL LOAD CREATED BY ADDING
 TANKLESS WATER HEATER IN UNIT 2502. THE MAIN ELECTRIC
 SERVICE DEMAND MUST BE SIZED FOR THE INCREASED LOAD.
 THE ELECTRIC UTILITY NEEDS TO VERIFY THE INCOMING
 SERVICE AND TRANSFORMER HAVE THE CAPACITY TO HANDLE
 TANKLESS WATER HEATING AS A STANDARD RETO FIT FOR THIS
 BUILDING.
  
 ROBERT LECKY, PLANS EXAMINER 561 805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-02-15 Cont ID  
Sent By wjolin Date 2011-02-15 Time 10:39 Rev Time 0.00
Received By wjolin Date 2011-02-15 Time 10:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-12-17 Cont ID  
Sent By wjolin Date 2010-12-17 Time 11:50 Rev Time 0.00
Received By wjolin Date 2010-12-17 Time 10:28 Sent To  
Notes
2010-12-17 11:50:325200 NORTH FLAGLER DRIVE, #2502 & #2503
 PERMIT #10120173
 REVIEW COMMENTS - FIRE
  
  
 DOORS THAT OPEN (EXISTING ENTRANCE DOORS) ONTO EXIT
 ACCESS CORRIDORS SHALL HAVE NOT LESS THAN A 20-MINUTE
 FIRE PROTECTION RATING AND SHALL BE SELF-CLOSING AND
 SELF-LATCHING.
  
 REMOVE NON-FUNCTIONING ENTRANCE DOOR (UNIT 2502) TO
 AVOID CONFUSION FOR EMERGENCY RESPONDERS TRYING TO GAIN
 ACCESS TO THE UNIT.
  
 THE HARD-WIRED SMOKE ALARMS SHALL SOUND ONLY WITHIN THE
 DWELLING UNIT; SMOKE ALARMS SHALL NOT BE TIED INTO THE
 BUILDING FIRE ALARM SYSTEM.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-02-01 Cont ID  
Sent By lmartine Date 2011-02-01 Time 11:19 Rev Time 0.00
Received By lmartine Date 2011-02-01 Time 11:19 Sent To  
Notes
2011-02-01 11:20:46B--13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-04 Cont ID  
Sent By hmoser Date 2011-01-04 Time 14:58 Rev Time 0.00
Received By hmoser Date 2010-12-09 Time 14:23 Sent To  
Notes
2010-12-09 14:36:12B--17

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-01-04 Cont ID  
Sent By hmoser Date 2011-01-04 Time 14:58 Rev Time 0.00
Received By hmoser Date 2011-01-04 Time 14:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-12-14 Cont ID  
Sent By lwagner Date 2010-12-14 Time 14:01 Rev Time 0.00
Received By lwagner Date 2010-12-14 Time 13:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-12-30 Cont ID  
Sent By lfranco Date 2010-12-30 Time 11:33 Rev Time 0.00
Received By lfranco Date 2010-12-30 Time 11:33 Sent To  
Notes
2010-12-30 11:34:54PLANNING AND ZONING: **** *ZONING REVIEW NOT REQUIRED:
 INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES
 NOT EXCEED 50% OF THE IMPROVEMENT VALUE. ****