Plan Review Details - Permit 10120071
Plan Review Stops For Permit 10120071
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-12-21 Cont ID  
Sent By shill Date 2010-12-21 Time 14:11 Rev Time 0.00
Received By shill Date 2010-12-21 Time 14:11 Sent To  
Notes
2010-12-21 14:14:31****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PROVIDE AWNING FABRIC REMOVAL INSTRUCTIONS TO SHOW
 COMPLIANCE WITH FBC3105.4.2.1, QUICK RELEASE. THE
 INSTRUCTIONS SHOULD CONSIST OF A SERIES OF PHOTOGRAPHS.
 THIS IS TO BE APPROVED BY THE BUILDING OFFICIAL.
  
 2. PER BUILDING OFFICIAL, WE ARE TO PUT ON THE PERMIT
 FILE A LETTER, OR CONTRACTORS FORM, SIGNED BY THE OWNER
 (NOT THE TENANT) TO ACKNOWLEDGE THEIR RESPONSIBILITY TO
 HAVE THE AWNING COVER REMOVED PRIOR TO ANY WIND EVENT
 WITH PROJECTED WIND SPEEDS OF 75 MPH OR GREATER. THE
 LETTER/FORM MUST BE SIGNED BY THE OWNER BUT IT NEED NOT
 BE NOTARIZED.
  
 3. FBC3501.3.5, PROVIDE DOCUMENTATION TO SHOW THAT THE
 FABRIC MEETS THE REQUIREMENT OF NFPA701.
  
 4. PROVIDE DISTANCE FROM GRADE TO BOTTOM OF AWNING, SEE
 FBC3105.1.
  
 5. REVISE SITE PLAN TO SHOW PROPOSED AWNING LOCATION.
  
 6. SEE FBC3105.4, PLAN INCORRECTLY STATES THAT FABRIC
 TO BE REMOVED AT 75MPH SUSTAINED 90MPH 3 SECOND GUST.
 PLEASE SEE FBC3105.4 FOR DESIGN CRITERIA.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-12-21 Cont ID  
Sent By shill Date 2010-12-21 Time 14:28 Rev Time 0.00
Received By shill Date 2010-12-03 Time 11:01 Sent To  
Notes
2010-12-03 11:02:00SENT TO ZONING BOX.

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-12-13 Cont ID  
Sent By jroach Date 2010-12-13 Time 13:19 Rev Time 0.00
Received By jroach Date 2010-12-07 Time 10:52 Sent To B
Notes
2010-12-13 13:19:34ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 12/13/10
 PERMIT NO.: 10120071
 ADDRESS: 740 BELVEDERE ROAD
 CONTRACTOR/CONTACT: CPL CONSTRUCTION, INC.
 TELEPHONE NO.: 561.791.7833
 SCOPE OF REVIEW: STEEL AWNING AS PER PLANS.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE TWO (2) COPIES OF THE SURVEY SHALL NOTE THE
 LOCATION OF THE PROPOSED AWNING. PLEASE INDICATE THE
 DIMENSIONS OF THE AWNING ON THE SURVEY, THE SETBACKS
 FROM THE AWNING TO THE ADJACENT PROPERTY LINES.
  
 2. PLEASE PROVIDE AN ELEVATION INDICATING THE LOCATION
 OF THE AWNING ON THE BUILDING AND THE HEIGHT AT WHICH
 THE AWNING WILL BE ATTACHED.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy