Plan Review Details - Permit 10110409
Plan Review Stops For Permit 10110409
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 14:45 Rev Time 0.00
Received By rmcdouga Date 2010-11-17 Time 14:45 Sent To  
Notes
2010-11-17 14:49:15PROVISO
  
 IN ORDER TO REDUCE THE OCCURRENCE OF GALVANIC CORROSION
 ROOF METAL INSTALLATION SHALL COMPLY WITH RAS 111
 SECTION 4.3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-16 Time 07:55 Rev Time 0.00
Received By rmcdouga Date 2010-11-16 Time 07:55 Sent To  
Notes
2010-11-16 12:21:14DENIED BY BUILDING
  
 1) ITEM NUMBER 4 OF THE PROPOSED WORK ON THE ESTIMATE
 SPECIFIES COPPER DRIP EDGE, FLASHING AND VENTS AND
 GALVANIZED HIP AND RIDGE CHANNEL, BREAK AND VALLEY
 METAL. RAS 111 SECTION 4 REQUIRES ROOF METALS TO BE
 COMPATIBLE IN ORDER TO MINIMIZE GALVANIC CORRISION. THE
 COPPER AND GALVANIZED STEEL ARE NOT COMPATIBLE. PLEASE
 SPECIFY HOW COMPLIANCE WITH THIS REQUIREMENT WILL BE
 MET.
  
 2) SPECIFY THE SLOPE OF THE PITCHED ROOF.
  
 3) SPECIFY THE SQUARE FEET OF THE FLAT ROOF AND OF THE
 SLOPED ROOF.
  
 4) SPECIFY THE MEAN ROOF HEIGHT OF THE STRUCTURE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]