Plan Review Details - Permit 10110215
Plan Review Stops For Permit 10110215
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-05-16 Cont ID  
Sent By jwitmer Date 2011-05-16 Time 11:51 Rev Time 0.77
Received By jwitmer Date 2011-05-16 Time 11:51 Sent To  
Notes
2011-05-16 12:03:22NEW A-1 SHEET WITH FIRE SHUTTER AT ELEVATOR TO
 STAIRWELL, CUT DETAILS OF FIRE SHUTTER AND FIRE SHUTTER
 PRODUCT SPEC FOR AUTO-SET SYSTEM MODEL CFS-M-G AS
 MANUFACTURED BY MCKEON DOOR COMPANY. THE AUTOMATIC
 RELEASE MECHANISM SHALL BE ACTIVATED BY A FUSEABLE
 LINK, SMOKE DETECTOR OR FIRE ALARM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2011-05-03 Cont ID  
Sent By jwitmer Date 2011-05-03 Time 10:23 Rev Time 0.77
Received By jwitmer Date 2011-05-03 Time 10:23 Sent To  
Notes
2011-05-03 10:42:27BUILDING PLAN REVIEW-
 PERMIT: 08060519
 ADD: 309 CLEMATIS ST
 CONT: WELLINGTON EQUESTRIAN
 TEL: (561)312-6247 JOHN WEBB
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVISION: DENIED
  
 1) THE SUBMITTED REVISION INDICATES A NEW AUTOMATIC
 FIRE SHUTTER IN THE FRONT STAIRWELL BETWEEN THE 2ND AND
 3RD FLOOR. THIS FIRE SHUTTER LEADS TO AN AREA THAT CAN
 BE CONSTRUED AS A MECHANICAL ROOM SINCE THIS WILL BE
 THE DOORWAY TO WORK ON THE EXISTING MECHANICAL
 EQUIPMENT BETWEEN THE EXISTING ROOFTOP AND THE NEW
 THIRD FLOOR ROOF TOP ADDITION.
  
 THE PERMIT SET OF PLANS LS-1 OR A2.0 DATED REVISION# 3
 5/11/09 DID NOT HAVE SUCH A DOORWAY IN THE VERTICAL
 EXIT STAIRWELL. PLEASE REVIEW:
  
 2004 FBC-B 1020.5 PENETRATIONS ALLOWED IN THE STAIRWELL
 ARE LIMITED OR PROHIBITED EXCEPT FOR THE REQUIRED
 EXITDOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR
 INDEPENDENT PRESSURIZATION, SPRINKLER PIPING,
 STANDPIPES, ELECTRIC RACEWAYS, FOR FIRE DEPARTMENT
 COMMUNICATIONS AND ELECTRICAL RACEWAY SEERVING NOT MORE
 THE EXIT PASSAGEWAY AND TERMINATING AT A STEEL BOX NOT
 EXCEEDING 16 SQUARE INCHES. SUCH PENETRATIONS SHALL BE
 PROTECTED IN ACCORDANCE WITH SECTION 712.
  
 THERE HAS BEEN MEETINGS ABOUT THIS PARTICULAR
 SITUATION, AND THE AGREEMENT WAS TO HAVE A VESTIBULE
 WITH TWO SETS OF 1 1/2 HR DOORS. THE INTENT WAS TO NOT
 HAVE A MECHANICAL ROOM OPEN DIRECTLY INTO THE STAIRWELL
 TRYING TO MEET THE INTENT OF 1020.5.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-05-03 Cont ID  
Sent By jwitmer Date 2011-05-03 Time 09:52 Rev Time 0.00
Received By jwitmer Date 2011-05-03 Time 09:52 Sent To  
Notes
2011-05-03 09:54:26 
 BUILDING PLAN REVIEW
 PERMIT: 10110215
 ADD: 309 CLEMATIS ST.
 CONT: WELLINGTON EQUESTRIAN
 TEL: (561)312-6247
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 REVIEW
 ACTION: DENIED

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-11-10 Cont ID  
Sent By jwitmer Date 2010-11-10 Time 15:05 Rev Time 1.33
Received By jwitmer Date 2010-11-10 Time 15:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2010-11-08 Cont ID  
Sent By jdickins Date 2010-11-08 Time 16:15 Rev Time 0.00
Received By jdickins Date 2010-11-08 Time 16:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2011-05-17 Cont ID  
Sent By mcarsill Date 2011-05-17 Time 10:56 Rev Time 0.00
Received By mcarsill Date 2011-05-17 Time 10:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-04-29 Cont ID  
Sent By mcarsill Date 2011-04-29 Time 07:14 Rev Time 0.00
Received By mcarsill Date 2011-04-29 Time 07:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-11-30 Cont ID  
Sent By mcarsill Date 2010-11-30 Time 09:15 Rev Time 0.00
Received By mcarsill Date 2010-11-30 Time 08:57 Sent To  
Notes
2010-11-30 09:14:58ROXY'S PUB
 309 CLEMATIS STREET
 MASTER PERMIT NUMBER 08060519
 REVISION TRACKING NUMBER 10110215
  
  
 1. ON SHEET A-1 IT WAS NOTED "OPENING TO BE PROTECTED
 BY A SELF-CLOSING 2 HOUR FIRE RATED SHUTTER ACTIVATED
 VIA FIRE ALARM OR POWER FAILURE". WHAT PREVENTS THE
 FIRE SHUTTER WHEN ACTIVATED FROM STRIKING PERSONS
 LOCATED IN THE ELEVATOR LOBBY OR PASSING THROUGH THE
 EXISTING STAIR # 1 OPENING THAT COMMUNICATES WITH THE
 ELEVATOR LOBBY. WHY IS NOT A FIRE RATED SIDE-SWINGING
 DOOR NOT BEING PLANNED FOR THIS LOCATION. THIS DOOR
 COULD REMAIN CLOSED AT ALL TIMES EXCEPT TO PASS THROUGH
 AND BE EQUIPPED WITH APPROPRIATE SIGNAGE INSTALLED TO
 PREVENT ACCIDENTS. THE OTHER PROBLEM THAT MAY POSE
 ISSUES FOR THE OWNER WITH THE FIRE SHUTTER BEING
 CONNECTED TO THE FIRE ALARM SYSTEM OR WHEN LOSS OF
 POWER OCCURS IS THE RE-SETTING OF THE FIRE SHUTTERS.
 SOMETIMES TECHNICIANS ARE NEEDED TO RE-SET THE SHUTTER
 WHICH COULD CREATE COST PROBLEMS.
 IF IT IS THE DESIRE TO INSTALL A FIRE SHUTTER ON THE
 FIRST FLOOR IT MAY BE CONSIDERED TO CONNECT IT TO SMOKE
 DETECTORS THAT ARE PROPRIETARY TO THE SHUTTER OR BE
 ACTIVATED BY A FUSIBLE LINK WHEREBY NUISANCE DROPS DO
 NOT OCCUR. PLEASE ADVISE SOLUTION AFTER HAVING
 CONSIDERING THIS INFORMATION.
  
 2. THE FLORIDA FIRE PREVENTION CODE (NFPA 101) SECTION
 9.4.7 INDICATES THAT "CONVEYORS, ELEVATORS,
 DUMBWAITERS, AND PNEUMATIC CONVEYORS SERVING VARIOUS
 STORIES OF A BUILDING SHALL NOT OPEN TO AN EXIT.
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-17 Cont ID  
Sent By jwitmer Date 2011-05-17 Time 11:41 Rev Time 0.00
Received By jwitmer Date 2011-04-27 Time 16:04 Sent To  
Notes
2011-04-27 16:06:55SENT TO C-11. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2011-05-03 Cont ID  
Sent By jwitmer Date 2011-05-03 Time 10:45 Rev Time 1.55
Received By jwitmer Date 2010-11-05 Time 16:45 Sent To  
Notes
2010-11-05 16:55:14B--3