Plan Review Stops For Permit 10110215 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2011-05-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-16 |
Time |
11:51 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-05-16 |
Time |
11:51 |
Sent To |
|
|
Notes |
2011-05-16 12:03:22 | NEW A-1 SHEET WITH FIRE SHUTTER AT ELEVATOR TO | | STAIRWELL, CUT DETAILS OF FIRE SHUTTER AND FIRE SHUTTER | | PRODUCT SPEC FOR AUTO-SET SYSTEM MODEL CFS-M-G AS | | MANUFACTURED BY MCKEON DOOR COMPANY. THE AUTOMATIC | | RELEASE MECHANISM SHALL BE ACTIVATED BY A FUSEABLE | | LINK, SMOKE DETECTOR OR FIRE ALARM. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2011-05-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-03 |
Time |
10:23 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-05-03 |
Time |
10:23 |
Sent To |
|
|
Notes |
2011-05-03 10:42:27 | BUILDING PLAN REVIEW- | | PERMIT: 08060519 | | ADD: 309 CLEMATIS ST | | CONT: WELLINGTON EQUESTRIAN | | TEL: (561)312-6247 JOHN WEBB | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVISION: DENIED | | | | 1) THE SUBMITTED REVISION INDICATES A NEW AUTOMATIC | | FIRE SHUTTER IN THE FRONT STAIRWELL BETWEEN THE 2ND AND | | 3RD FLOOR. THIS FIRE SHUTTER LEADS TO AN AREA THAT CAN | | BE CONSTRUED AS A MECHANICAL ROOM SINCE THIS WILL BE | | THE DOORWAY TO WORK ON THE EXISTING MECHANICAL | | EQUIPMENT BETWEEN THE EXISTING ROOFTOP AND THE NEW | | THIRD FLOOR ROOF TOP ADDITION. | | | | THE PERMIT SET OF PLANS LS-1 OR A2.0 DATED REVISION# 3 | | 5/11/09 DID NOT HAVE SUCH A DOORWAY IN THE VERTICAL | | EXIT STAIRWELL. PLEASE REVIEW: | | | | 2004 FBC-B 1020.5 PENETRATIONS ALLOWED IN THE STAIRWELL | | ARE LIMITED OR PROHIBITED EXCEPT FOR THE REQUIRED | | EXITDOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR | | INDEPENDENT PRESSURIZATION, SPRINKLER PIPING, | | STANDPIPES, ELECTRIC RACEWAYS, FOR FIRE DEPARTMENT | | COMMUNICATIONS AND ELECTRICAL RACEWAY SEERVING NOT MORE | | THE EXIT PASSAGEWAY AND TERMINATING AT A STEEL BOX NOT | | EXCEEDING 16 SQUARE INCHES. SUCH PENETRATIONS SHALL BE | | PROTECTED IN ACCORDANCE WITH SECTION 712. | | | | THERE HAS BEEN MEETINGS ABOUT THIS PARTICULAR | | SITUATION, AND THE AGREEMENT WAS TO HAVE A VESTIBULE | | WITH TWO SETS OF 1 1/2 HR DOORS. THE INTENT WAS TO NOT | | HAVE A MECHANICAL ROOM OPEN DIRECTLY INTO THE STAIRWELL | | TRYING TO MEET THE INTENT OF 1020.5. | | | | JAMES A. WITMER C.B.O. | | COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: (561)805-6715 | | FAX:(561)805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2011-05-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-03 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-05-03 |
Time |
09:52 |
Sent To |
|
|
Notes |
2011-05-03 09:54:26 | | | BUILDING PLAN REVIEW | | PERMIT: 10110215 | | ADD: 309 CLEMATIS ST. | | CONT: WELLINGTON EQUESTRIAN | | TEL: (561)312-6247 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | REVIEW | | ACTION: DENIED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-11-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-11-10 |
Time |
15:05 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2010-11-10 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2010-11-08 |
|
|
Cont ID |
|
Sent By |
jdickins |
Date |
2010-11-08 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
jdickins |
Date |
2010-11-08 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2011-05-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2011-05-17 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2011-05-17 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2011-04-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2011-04-29 |
Time |
07:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2011-04-29 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-11-30 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-11-30 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-11-30 |
Time |
08:57 |
Sent To |
|
|
Notes |
2010-11-30 09:14:58 | ROXY'S PUB | | 309 CLEMATIS STREET | | MASTER PERMIT NUMBER 08060519 | | REVISION TRACKING NUMBER 10110215 | | | | | | 1. ON SHEET A-1 IT WAS NOTED "OPENING TO BE PROTECTED | | BY A SELF-CLOSING 2 HOUR FIRE RATED SHUTTER ACTIVATED | | VIA FIRE ALARM OR POWER FAILURE". WHAT PREVENTS THE | | FIRE SHUTTER WHEN ACTIVATED FROM STRIKING PERSONS | | LOCATED IN THE ELEVATOR LOBBY OR PASSING THROUGH THE | | EXISTING STAIR # 1 OPENING THAT COMMUNICATES WITH THE | | ELEVATOR LOBBY. WHY IS NOT A FIRE RATED SIDE-SWINGING | | DOOR NOT BEING PLANNED FOR THIS LOCATION. THIS DOOR | | COULD REMAIN CLOSED AT ALL TIMES EXCEPT TO PASS THROUGH | | AND BE EQUIPPED WITH APPROPRIATE SIGNAGE INSTALLED TO | | PREVENT ACCIDENTS. THE OTHER PROBLEM THAT MAY POSE | | ISSUES FOR THE OWNER WITH THE FIRE SHUTTER BEING | | CONNECTED TO THE FIRE ALARM SYSTEM OR WHEN LOSS OF | | POWER OCCURS IS THE RE-SETTING OF THE FIRE SHUTTERS. | | SOMETIMES TECHNICIANS ARE NEEDED TO RE-SET THE SHUTTER | | WHICH COULD CREATE COST PROBLEMS. | | IF IT IS THE DESIRE TO INSTALL A FIRE SHUTTER ON THE | | FIRST FLOOR IT MAY BE CONSIDERED TO CONNECT IT TO SMOKE | | DETECTORS THAT ARE PROPRIETARY TO THE SHUTTER OR BE | | ACTIVATED BY A FUSIBLE LINK WHEREBY NUISANCE DROPS DO | | NOT OCCUR. PLEASE ADVISE SOLUTION AFTER HAVING | | CONSIDERING THIS INFORMATION. | | | | 2. THE FLORIDA FIRE PREVENTION CODE (NFPA 101) SECTION | | 9.4.7 INDICATES THAT "CONVEYORS, ELEVATORS, | | DUMBWAITERS, AND PNEUMATIC CONVEYORS SERVING VARIOUS | | STORIES OF A BUILDING SHALL NOT OPEN TO AN EXIT. | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-05-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-17 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-04-27 |
Time |
16:04 |
Sent To |
|
|
Notes |
2011-04-27 16:06:55 | SENT TO C-11. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
F |
Date |
2011-05-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-03 |
Time |
10:45 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2010-11-05 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|