Plan Review Stops For Permit 10100660 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2010-10-27 |
|
|
Cont ID |
|
Sent By |
jnguyen |
Date |
2010-10-27 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
jnguyen |
Date |
2010-10-27 |
Time |
13:00 |
Sent To |
|
|
Notes |
2010-10-27 17:03:47 | I WENT OUT & DID A FIELD INSPECTION. I NOTICED THAT 208 | | N SAPODILLA AVE WAS ACTUALLY THE SECONDARY ADDRESS FOR | | ONE OF THE UNITS FOR THE BUILDING ON A COMPLETELY | | DIFFERENT PARCEL, PCN# 74434321010270041 (WHICH IS THE | | ONE ACROSS THE STREET WITH A PRIMARY ADDRESS OF 210 N | | SAPODILLA AVE FOR THE OTHER UNIT). THE WORK FOR THIS | | PERMIT IS TO REPLACE A BROKEN GENERATOR, WHICH ACTUALLY | | TAKES PLACE IN THE WEST PARCEL BOUNDARY OF PCN# | | 74434321010380010 (AN OPEN STORAGE AREA WITH A GARAGE & | | ACCESS OFF 2ND ST). PCN# 74434321010380010 ALSO | | CONSISTS OF A FACILITY AT 209 N SAPODILLA AVE (PRIMARY | | ADDRESS) IN THE EAST PARCEL BOUNDARY. SINCE THE | | PERMITTED WORK TAKES PLACE IN THE WEST PARCEL BOUNDARY | | OF PCN# 74434321010380010 "WITH ACCESS OFF 2ND ST", I | | HAVE ASSIGNED THE OPEN STORAGE AREA THE SECONDARY | | ADDRESS OF 804 2ND ST (I SENT OUT AN E-MAIL | | NOTIFICATION TO ALL OF THE RELEVANT PARTIES.). I HAVE | | PROPERLY REFERENCED THIS PERMIT FROM 208 N SAPODILLA | | AVE TO 804 2ND ST OF PCN# 74434321010380010 IN THE | | COMMUNITYPLUS DATABASE. SINCE I WAS ONLY PROVIDED WITH | | A COPY, PLEASE CORRECT IT ON THE ORIGINAL PERMIT | | APPLICATION TO 804 2ND ST. | | | | JOHN NGUYEN | | GIS SUPPORT SPECIALIST | | CITY OF WEST PALM BEACH | | MIS DEPARTMENT | | OFFICE: (561) 822-1239 | | FAX: (561) 822-1249 | | [email protected] | | | | | | | | | 2010-10-27 12:29:39 | ATTACHED IS LETTERHEAD FROM FL PUBLIC UTILITIES THAT | | STATES THEY ARE AT "208 N. SAPODILLA" |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-05-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-05-16 |
Time |
14:08 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
2011-05-16 |
Time |
14:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-11-22 |
Time |
17:13 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
2010-11-22 |
Time |
17:10 |
Sent To |
|
|
Notes |
2010-11-22 17:21:13 | BUILDING PLAN REVIEW | | PERMIT: 10100660 | | ADD: 804 2ND ST | | CONT: POWER PRO-TECH SERVICES, INC | | TEL: (561)859-1523 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST BUILDING REVIEW | | ACTION: DENIED | | | | 1) THIS IS A REPLACEMENT GENERATOR LOCATED OUTSIDE OF | | ANY STRUCTURE, PLANS FAIL TO IDENTIFY WIND DESIN | | CRITERIA: | | 1609.6.2 WIND DESIGN PROCEDURES | | 1.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN | | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE | | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. | | | | 1.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN | | ACCORDANCE WITH SECTION1609.5. | | | | 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4. | | | | 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) | | | | 2) PLANS FAIL TO IDENTIFY HOW THE GENERATOR WILL BE | | INSTALLED (ANCHORED) TO RESIST THE MOMENT OF | | OVERTURNING AND OR SLIPPING | | FBC-B 1604.3.6 & 1609. | | | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2011-05-11 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-05-11 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-05-10 |
Time |
14:36 |
Sent To |
|
|
Notes |
2011-05-11 16:46:43 | | | PREVIOUS ELECTRICAL REVIEW COMMENT NOT ADDRESSED. THE | | FOLLOWING ITEMS ARE STILL NEEDED. | | | | PROVIDE A SUMMARY LOAD CALCULATION SHOWING THE LOADS | | SERVED BY THE GENERATOR. INDICATE THE VOLTAGE AND | | PHASES. ON THE RISER PLAN INDICATE THE DATE, DESIGNER | | AND COMPANY. | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-11-01 |
|
|
Cont ID |
|
Sent By |
jdickins |
Date |
2010-11-01 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
jdickins |
Date |
2010-11-01 |
Time |
16:50 |
Sent To |
|
|
Notes |
2010-11-01 17:08:18 | ************ELECT DENIED************* | | 1)PAPER WORK FOR ATS DOES NOT SHOW A UL OR OTHER | | APPROVED TEST LAB. | | 2) SUBMIT A RISER DIAGRAM SHOWING ALL MAIN SERVICE | | ELECTRICAL EQUIPMENT. | | 3) ELECTRICAL PLAN IS REQUIRED TO HAVE DESIGNERS NAME, | | LICENSE MUMBER,AND BE SIGNED | | 4) SHOW LOADS BEING SERVED | | 5) SUBMIT LOAD CALCUATIONS ON GENERATOR | | 6) SUBMIT SERVEY SITE PLAN SHOWING GENERATOR LOCATION | | AND EXHUST IN REFERANCE TO ANY BUILDING OPENINGS | | DOORS,WINDOWS,VENTS. | | JOHN DICKINSON | | CONTRACT PLAN REVIEWER CITY OF WEST PALM BEACH | | CELL PHONE 561-718-3232 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2010-11-19 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-11-19 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-11-19 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-11-22 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-11-22 |
Time |
13:58 |
Sent To |
|
|
Notes |
2010-11-22 14:05:35 | REVIEW FOR GAS PERMIT #10110477 IS PASSED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-11-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-05-16 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-04-20 |
Time |
10:39 |
Sent To |
|
|
Notes |
2011-05-11 16:52:26 | TO JW | 2011-05-10 11:35:13 | 5/10 TO ELECTRICAL | 2011-04-20 10:42:33 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-11-22 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-10-27 |
Time |
13:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2011-04-28 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2011-04-28 |
Time |
17:05 |
Rev Time |
0.25 |
Received By |
aaponte |
Date |
2011-04-21 |
Time |
14:24 |
Sent To |
|
|
Notes |
2011-04-28 17:05:33 | COMMENTS FROM PREVIOUS REVIEW NOT ADDRESSED. FOR | | ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA APONTE | | AT 561-822-1439. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2010-11-22 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2010-11-22 |
Time |
14:41 |
Sent To |
|
|
Notes |
2010-11-22 14:47:26 | 1. A SURVEY OF THE PROPERTY SHALL BE INCLUDED WITH | | SUBMITTAL. | | 2. A SITE PLAN SHALL BE INCLUDED INDICATING THE | | LOCATION OF PROPOSED GENERATOR. | | 3. OUTDOOR MECHANICAL EQUIPMENT SHALL BE SCREENED WITH | | A WALL AND SHALL BE LANDSCAPED ACCORDING TO ARTICLE IV | | SECTION 94-113(H) OF THE ZONING REGULATIONS. | | FOR ADDITIONAL INFORMATION PLEASE CONTRACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|