Plan Review Details - Permit 10100632
Plan Review Stops For Permit 10100632
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-05-18 Cont ID  
Sent By jwitmer Date 2011-05-18 Time 15:39 Rev Time 0.00
Received By lmartine Date 2011-05-18 Time 14:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-11-19 Cont ID  
Sent By jwitmer Date 2010-11-19 Time 15:45 Rev Time 1.33
Received By jwitmer Date 2010-11-19 Time 15:45 Sent To  
Notes
2010-11-19 16:55:18BUILDING PLAN REVIEW
 PERMIT: 10100632
 ADD: 319 CLEMATIS ST 1ST FLOOR
 CONT: WELLINGTON, EQUESTION
 TEL: (561)951-6729
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 REVIEW
 ACTION: DENIED
 1) SHEET A-4 INDICATES A BUILDING CODE ANALYSIS, PLANS
 INDICATE IT TO BE A TYPE 5B, PLEASE SEE 2007 FBC-B
 TABLE 503, THIS BEING A HIGH RISE PLEASE REVIEW TYPE
 L-A AND L-B. DEPENDING ON THE BUILDING HEIGHT IIN
 STORIES IT IS EITHER A I-A OR I-B. PLEASE CORRECT.
  
 2) PLEASE REVIEW THE SCALE THE PLANS ARE DRAWN TO, THE
 PLANS INDICATE 1/4 INCH BUT SCALE OUT TO BE 3/16 OF AN
 INCH FOR ALL DOOR
 WAYS. THIS WILL DRAMATICALLY EFFECT TRAVEL DISTANCES.
  
 3) THE MAIN DINING ROOM DOES HAVE 2 EXITS THAT WILL
 MEET THE 1/3RD THE DIAGONAL, BUT NOT THE REQUIREMENTS
 OF FBC-B 1014.3(5) COMMON PATH OF TRAVEL. PLEASE
 PROVIDE THE IDSTANCES FOR THE COMMON PATH OF TRAVEL
 DISTANCES FROM THE MOST REMOTE POINT IN THE TENANT
 SPACE . COMMON PATH OF TRAVEL IS MEASURED FROM THE MOST
 REMOTE POINT IN A SPACE TO THE POINT IN THE EXIT PATH
 WHERE AN OCCUPANT HAS ACCESS TO TWO REQUIRED EXITS IN
 SEPERATE DIRECTIONS.
  
 4) THE MAIN DINING ROOM REQUIRES TWO EXITS 1/3RD THE
 DISTANCE APART, THE DOORWAYS ARE THERE BUT NOT THE
 SECOND REQUIRED EXIT ACCESS, IT IS BLOCKED BY DINING
 ROOM TABLES. FBC-B 1015.2 & 1005.1 MULTIPLE MEANS OF
 EGRESS SHALL BE SIZED SUCH THAT THE LOSS OF ANY ONE
 MEANS OF EGRESS SHALL NOT REDUCE THE AVAILABLE CAPACITY
 TO LESS THAN 50 PERCENT OF THE REQUIRED CAPACITY.
  
 5) THE PLANS DO NOT PROVIDE ANY FINISH INFORMATION FOR
 FLOOR, WALL OR CEILING FINISHES PER FBC-B 803.1 & TABLE
 803.5.
  
 6) THE PLANS ALSO WILL NEED TO SHOW COMPLIANCE WITH :
 11-5.2 COUNTERS AND BARS. WHERE FOOD OR DRINK IS SERVED
 AT COUNTERS EXCEEDING 34 INCHES (865 MM) IN HEIGHT FOR
 CONSUMPTION BY CUSTOMERS SEATED ON STOOLS OR STANDING
 AT THE COUNTER, A PORTION OF THE MAIN COUNTER WHICH IS
 60 INCHES (1525 MM) IN LENGTH MINIMUM SHALL BE PROVIDED
 IN COMPLIANCE WITH SECTION 11-4.32 OR SERVICE SHALL BE
 AVAILABLE AT ACCESSIBLE TABLES WITHIN THE SAME AREA.
  
 11-5.3 ACCESS AISLES. ALL ACCESSIBLE FIXED TABLES SHALL
 BE ACCESSIBLE BY MEANS OF AN ACCESS AISLE AT LEAST 36
 INCHES (915 MM) CLEAR BETWEEN PARALLEL EDGES OF TABLES
 OR BETWEEN A WALL AND THE TABLE EDGES.
  
 7) NEITHER A-4 OR E-1 PROVIDE FOR COMPLIANCE WITH FBC-B
 1006.1.1 MEANS OF EGRESS ILLUMINATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-05-24 Cont ID  
Sent By rlecky Date 2011-05-24 Time 09:42 Rev Time 0.00
Received By rlecky Date 2011-05-24 Time 09:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-11-16 Cont ID  
Sent By jdickins Date 2010-11-16 Time 18:03 Rev Time 0.00
Received By jdickins Date 2010-11-16 Time 18:03 Sent To  
Notes
2010-11-16 18:35:171) SUBMIT MODEL NUMBERS OF NEW LIGHTING FIXTURES.
 2) SUBMIT LIGHTING DENSITIE CALCULATIONS AS PER
 13-415.ABC 2007 F.B.C.
 3) SHOW LOCATION OF EXISTING PANELS.
 4) DO NOT UNDERSTAND RISER DIAGRAM,PLEASE REDRAW
 SHOWING ORDER OF EQUIPMENT.
 5) SHOW SIZE OF MAIN FEEDERS FROM 600 AMP MAIN TO
 PANELS.
 6) PANEL SCHEDULE SHOWS PANEL B AS BEING 100 AMP BUS.
  
 JOHN DICKINSON
 CONTRACT PLAN REVIEWER
 CELL NUMBER 561-718-3230

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-05-19 Cont ID  
Sent By mcarsill Date 2011-05-19 Time 09:20 Rev Time 0.00
Received By mcarsill Date 2011-05-19 Time 09:17 Sent To  
Notes
2011-05-19 09:19:56SMOOTY'S WINE DIVE
 319 CLEMATIS STREET
 PERMIT NUMBER 10100632
  
  
 1. OCCUPANT LOAD IS TO BE POSTED IN ESTABLISHMENT.
  
 2. TACTILE SIGNAGE REQUIRED AT EXIT DOORS.
  
 3. SEPARATE PLANS AND PERMITS REQUIRED FOR ANY FIRE
 SPRINKLER SYSTEM REMODELING.
  
  
 APPROVED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-11-16 Cont ID  
Sent By wjolin Date 2010-11-16 Time 13:43 Rev Time 0.00
Received By wjolin Date 2010-11-16 Time 11:03 Sent To  
Notes
2010-11-16 13:43:01319 CLEMATIS STREET, SUITE #100
 PERMIT #10100632
 REVIEW COMMENTS - FIRE
  
 SHEET A-4
  
 PROVIDE SCOPE OF FIRE SPRINKLER MODIFICATION. NOTE 50
 OR MORE SPRINKLERS REQUIRE THE SIGN AND SEAL OF A
 PROFESSIONAL ENGINEER. SEPARATE PLANS AND PERMIT
 REQUIRED FOR SPRINKLER WORK.
  
 PROVIDE SCOPE OF FIRE ALARM MODIFICATION. SEPARATE
 PLANS AND PERMIT REQUIRED FOR FIRE ALARM WORK.
  
 LOCATION OF EXIT SIGNS, EMERGENCY LIGHTS AND PORTABLE
 FIRE EXTINGUISHERS NOT SHOWN.
  
 PANIC/FIRE EXIT HARDWARE IS REQUIRED ON EXIT DOORS
 WHERE THE OCCUPANT LOAD EXCEEDS 100 PERSONS.
  
 IN BUILDINGS FULLY PROTECTED WITH AUTOMATIC SPRINKLERS,
 THE MINIMUM SEPARATION DISTANCE BETWEEN EXITS SHALL BE
 NOT LESS THAN ONE-THIRD THE LENGTH OF THE MAXIMUM
 OVERAL DIAGONAL DIMENSION OF BUILDING OR AREA BEING
 SERVED.
  
 SOUTH EXITS ARE OBSTRUCTED BY TABLES AND CHAIRS IF THEY
 ARE INTENDED TO BE USED AS EXITS. DOORS NOT INTENDED
 FOR EXIT USE SHALL BE MARKED AS "NOT AN EXIT."
  
 NO WHEELCHAIR SEATING HAS BEEN PROVIDED ON FURNITURE
 PLAN.
  
 PROVIDE THE ANTICIPATED AMOUNT (BOTTLES AND VOLUME) OF
 WINE THAT WILL BE PRESENT AT ANY TIME IN THIS
 OCCUPANCY.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
 (561) 805-6730

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-24 Cont ID  
Sent By lmartine Date 2011-05-24 Time 14:43 Rev Time 0.00
Received By lmartine Date 2011-05-13 Time 16:48 Sent To  
Notes
2011-05-13 16:53:37B--8

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-11-19 Cont ID  
Sent By jwitmer Date 2010-11-19 Time 16:57 Rev Time 0.00
Received By jwitmer Date 2010-10-28 Time 11:13 Sent To  
Notes
2010-10-28 11:13:30C13
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2010-11-19 Cont ID  
Sent By jwitmer Date 2010-11-19 Time 16:57 Rev Time 0.00
Received By jwitmer Date 2010-11-19 Time 16:56 Sent To  
Notes
2010-11-19 16:57:35NO MECHANICAL PLANS SUBMITTED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-05-24 Cont ID  
Sent By lwagner Date 2011-05-24 Time 07:45 Rev Time 0.00
Received By lwagner Date 2011-05-23 Time 13:53 Sent To  
Notes
2011-05-24 07:45:58RESTAMP

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-11-01 Cont ID  
Sent By lwagner Date 2010-11-01 Time 13:18 Rev Time 0.00
Received By lwagner Date 2010-11-01 Time 10:44 Sent To  
Notes
2010-11-01 13:18:34****PROVISO*****
  
 PLUMBING 704.5 - PROPERLY CAP
 BRANCHES WITH NO DEAD ENDS.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2011-05-24 Cont ID  
Sent By aaponte Date 2011-05-24 Time 13:47 Rev Time 0.00
Received By aaponte Date 2011-05-24 Time 13:47 Sent To  
Notes
2011-05-24 13:48:55APPROVED AS A BONA-FIDE RESTAURANT.

Review Stop Z ZONING
Rev No 1 Status N Date 2010-11-15 Cont ID  
Sent By aaponte Date 2010-11-15 Time 09:42 Rev Time 0.00
Received By aaponte Date 2010-11-15 Time 09:42 Sent To  
Notes
2010-11-15 09:51:48AN ALCOHOLIC BEVERAGE ESTABLISHEMENT AS DEFINED IN THE
 CITY CODE IS NOT ALLOWED AT THIS LOCATION. ONLY A BONA
 FIDE RESTAURANT AS DEFINED BY THE CTIY CODE IS ALLOWED.
 PLEASE REFER TO CHAPTER 6, SECTION FOR DETAIL
 INFORMATION REGARDING REQUIREMENTS FOR BONA FIDE
 RESTAURANTS.