Plan Review Details - Permit 10100604
Plan Review Stops For Permit 10100604
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2010-12-20 Cont ID  
Sent By dwise Date 2010-12-20 Time 14:38 Rev Time 0.00
Received By dwise Date 2010-12-20 Time 14:38 Sent To  
Notes
2010-12-20 14:40:52CONTACT JIM RAPP OF RAPP CONSTRUCTION. ADVISED ALL
 REVIEWS WERE COMPLETE. NOTED NO ACCESSSIBLE SPACE WAS
 SHOWN ON PAVING AND DRAINAGE PLAN, BUT THAT AT LEAST
 ONE WOULD BE REQUIRED PURSUANT TO FBC CHAPTER 11
 (ACCESSIBILITY). NEW PARKING LOT ACCESIBILITY CRITERIA
 ARE HANDLED BY ESD. BUILDING REVIEW IS THEREFORE "NOT
 REQUIRED". DBW

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2011-03-16 Cont ID  
Sent By mgonzale Date 2011-03-16 Time   Rev Time 0.50
Received By mgonzale Date 2011-03-16 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2010-11-29 Cont ID  
Sent By mgonzale Date 2010-11-29 Time 15:37 Rev Time 0.50
Received By mgonzale Date 2010-11-29 Time 15:37 Sent To  
Notes
2010-11-29 15:55:31FAILED:
  
 PROVIDE THE FOLLOWING:
  
 CITY ORDINANCE 3132-98, SECTION 32-18(A): "...IT SHALL
 BE UNLAWFUL FOR ANY PERSON TO DIRECTLY OR INDIRECTLY
 DEPOSIT, DISCHARGE, SPILL, OR DUMP INTO ANY OF THE
 PUBLIC WATERS OR MUNICIPAL SEPARATE STORM SEWER SYSTEM
 WITHIN THE CITY, ANY SUBSTANCE OTHER THAN THAT COMPOSED
 ENTIRELY OF STORM WATER." AND, SECTION 32-18(C): "NO
 PERSON MAY MAINTAIN, USE OR ESTABLISH ANY DIRECT OR
 INDIRECT CONNECTION TO THE STORM WATER SYSTEM THAT
 RESULTS IN ANY DISCHARGE IN VIOLATION OF THIS
 ORDINANCE. THIS PROHIBITION IS RETROACTIVE AND APPLIES
 TO CONNECTIONS MADE IN THE PAST, REGARDLESS OF WHETHER
 MADE UNDER A PERMIT, OR OTHER AUTHORIZATION, OR WHETHER
 PERMISSIBLE UNDER LAWS OR PRACTICES APPLICABLE OR
 PREVAILING AT THE TIME THE CONNECTION WAS MADE."
  
 POLLUTION PREVENTION PLAN SO THAT IT IS IMPLEMENTED AND
 IN THE FIELD AT ALL TIMES.
 HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/DOCS/
 CONST_ACTIVITY.PDF
  
 ALL STORMWATER TREATMENT AND DISPOSAL FACILITIES MUST
 MEET THE DESIGN AND
 PERFORMANCE STANDARDS ESTABLISHED IN CHAPTER 17-25,
 F.A.C., WITH TREATMENT OF THE FIRST INCH OF RUN-OFF
 ON-SITE TO MEET WATER QUALITY STANDARDS REQUIRED BY CH.
 17-302, SECTION 17-302.500, F.A.C.
 STORMWATER DISCHARGE FACILITIES MUST BE DESIGNED SO AS
 NOT TO DEGRADE THE RECEIVING WATER BODY BELOW
 THE MINIMUM CONDITIONS NECESSARY TO ASSURE THE
 SUITABILITY OF WATER FOR THE DESIGNATED USE AS
 ESTABLISHED IN CHAPTER 17-302, F.A.C.
  
 STORMWATER RUNOFF FOR DEVELOPMENT WITHIN DEVELOPED
 AREAS AND SUBDIVISIONS MUST
 MEET THE FOLLOWING LEVEL OF SERVICE STANDARDS:
 (A) WATER QUANTITY
 POST-DEVELOPMENT RUN-OFF SHALL NOT EXCEED
 PRE-DEVELOPMENT RUNOFF RATES FOR
 THE ENTIRE DEVELOPMENT OR SUBDIVISION.
 (B) WATER QUALITY
 THE TREATMENT OF POST-DEVELOPMENT RUNOFF FROM THE SITE
 MUST ENSURE THAT
 RECEIVING WATER QUALITY CRITERIA ESTABLISHED IN CHAPTER
 17-302, SECTION 17-
 302.500, F.A.C. ARE MAINTAINED.
  
 PROVIDE A PROJECT NARRATIVE
 DRAINAGE CRITERIA
 WATER QUALITY CALCULATIONS
 EXFILTRATION TRENCH CALCULATIONS
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-03-18 Cont ID  
Sent By lmartine Date 2011-03-18 Time 16:45 Rev Time 0.00
Received By lmartine Date 2011-03-03 Time 13:46 Sent To  
Notes
2011-03-03 13:46:31IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-12-20 Cont ID  
Sent By dwise Date 2010-12-20 Time 14:41 Rev Time 0.00
Received By dwise Date 2010-10-28 Time 09:20 Sent To  
Notes
2010-10-28 09:20:57SENT TO ZONING BOX.

Review Stop Z ZONING
Rev No 2 Status P Date 2011-03-14 Cont ID  
Sent By eschneid Date 2011-03-14 Time 11:37 Rev Time 0.75
Received By eschneid Date 2011-03-08 Time 16:30 Sent To ENG
Notes
2011-03-14 13:19:17PASSED W/PROVISO
  
 1) PROVISO - ALL PARKING SPACES REQUIRE WHEEL STOPS TO
 PROTECT THE LANDSCAPE BUFFERS FROM VEHICULAR
 ENCROACHMENT.
  
 2) FENCES, GATES AND LIGHTING REQUIRE A SEPARATE
 PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446

Review Stop Z ZONING
Rev No 1 Status F Date 2010-11-09 Cont ID  
Sent By eschneid Date 2010-11-09 Time 14:45 Rev Time 1.00
Received By eschneid Date 2010-10-29 Time 10:54 Sent To ENG
Notes
2010-11-09 14:47:45FAILED
  
 PLEASE PROVIDE THE RESPONSES IN WRITING.
  
 1) PER THE MARCH 18, 2008 DETERMINATION LETTER FROM
 ANGELLA VANN TO JONI BRINKMAN, THE PARKING LOT REQUIRES
 REVIEW AND APPROVAL BY THE PLANS AND PLATS REVIEW
 COMMITTEE. THIS SHALL OCCUR PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT.
  
 2) PROVIDE A RECENT, LESS THAN ONE YEAR OLD, SURVEY OF
 THE SUBJECT AREA.
  
 3) PROVIDE THE DIMENSIONS OF THE ENTIRE LENGTH OF THE
 EACH PARKING ROW. THE PARKING DETAIL SHOWS 8.5 FEET
 WIDE SPACES WHILE THE PARKING ROWS WITH 10 PARKING
 SPACES SCALE TO LESS THAN REQUIRED 85 FEET ON THE PLAN.
  
 4) THE LANDSCAPE PLAN SHOWS A HANDICAP PARKING SPACE,
 ACCESS AISLE AND SIDEWALK THAT ARE NOT SHOWN ON THE
 PAVING PLAN.
  
 5) IF A HANDICAP PARKING SPACE IS REQUIRED, THEN THE
 CITY'S HANDICAP PARKING DETAIL SHALL BE INCLUDED ON THE
 PAVING PLAN.
  
 6) FIGURE XIV-2 LOCATED IN SECTION 94-443(C)(5) OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRES TWO
 (2) FEET FROM THE BACK OF THE WHEEL STOP TO THE END OF
 THE PARKING SPACE. UPDATE THE PARKING SPACE DETAIL
 ACCORDINGLY.
  
 7) PROVIDE A WHEEL STOP DETAIL IN ACCORDANCE WITH
 FIGURE XIV-2.
  
 8) PROVIDE THE DIMENSION FROM THE CURB FACE TO CURB
 FACE OF THE ENTRANCE DRIVE.
  
 9) PROVIDE THE DIMENSION FROM THE EDGE OF PAVEMENT TO
 EDGE OF PAVEMENT FOR THE FULL PARKING BAY (BOTH SPACES
 AND DRIVE AISLE) WIDTH OF THE PARKING LOT.
  
 10) PROVIDE THE DIMENSION OF THE PARKING BACK OUT
 ASSIST AREA.
  
 11) PROVIDE THE DIMENSION FROM THE PROPERTY LINE TO THE
 EDGE OF PAVEMENT OR CURBING AROUND THE PARKING LOT.
  
 12) ALL DIMENSIONS SHALL BE CONSISTENT WITH THE
 LANDSCAPE PLAN.
  
 13) FENCES, GATES AND LIGHTING REQUIRE A SEPARATE
 PERMIT.
  