Plan Review Stops For Permit 10100535 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-11-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-11-05 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-11-05 |
Time |
14:36 |
Sent To |
FIRE |
|
Notes |
2010-11-05 14:37:34 | PROVISO - PER ARCHITECT, DOORS COMPLY WITH EXPOSURE C | | PRESSURES. LETTER TO BE PROVIDED AT INSPECTION | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-11-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-11-04 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-11-03 |
Time |
17:20 |
Sent To |
|
|
Notes |
2010-11-04 14:03:33 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1. STATE WIND DESIGN CRITERIA (COMPONENT & CLADDING | | DESIGN PRESSURE REQUIREMENT) FOR THE NEW DOOR, | | FBC1603.1.4. | | | | 2ND REVIEW, PLEASE REVISE TO EXPOSURE C PER AERIAL OR | | CONTACT ME TO DISCUSS. | | | | 2. FBC TABLE 715.4, FIRE RATED WALLS NOT SHOWN ON THE | | PLAN. PLEASE NOTE RATED WALLS (OCCUPANCY SEPARATION | | BETWEEN BUSINESS AND S2) AND SHOW COMPLIANCE FOR THE | | DOOR IF APPLICABLE. | | | | 2ND REVIEW, FIRE SHUTTER IS NOW SHOWN OVER PROPOSED NEW | | GLAZED DOOR. IT APPEARS THAT THIS DOOR IS IN THE MEANS | | OF EGRESS, AND IS THE ONLY WAY TO EXIT THE ELEVATOR | | LOBBY IN THIS HIGH RISE BUILDING. ALSO NOTE THAT IT IS | | LIKELY THAT TWO EXITS ARE REQUIRED, AND ONE EXIT WOULD | | BE BLOCKED BY OPERATION OF THE FIRE SHUTTER. PLEASE | | PROVIDE A LIFE SAFETY PLAN TO SHOW HOW THIS CHANGE IN | | THE MEANS OF EGRESS AFFECTS EXITING (TRAVEL DISTANCE, | | REQUIRED EXITS, COMMON PATH, ETC., FBC CH 10). | | | | PLEASE NOTE THAT A FIRE DEPARTMENT REVIEW WILL BE | | REQUIRED AFTER SUBMISSION OF THE LIFE SAFETY PLAN. | | | | 3. PROVISO ITEM, SUBJECT TO FIELD INSPECTOR'S | | DISCRETION, A DETAIL PREPARED OR REVIEWED BY THE | | ARCHITECT FOR THE RAISED (EXISTING) DRAIN AND SLOPED | | CONCRETE TRANSITION MAY BE REQUIRED. | | | | 4. PROVISO ITEM, RE: A1, NOTE 5, "REMOVE AND REPLACE | | FIRE ALARM AND EMERGENCY DEVICES," ANY ALTERATIONS TO | | THE EXISTING FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE | | PERMIT AND REVIEW. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-10-21 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-10-21 |
Time |
08:08 |
Sent To |
|
|
Notes |
2010-10-21 08:31:37 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. STATE WIND DESIGN CRITERIA (COMPONENT & CLADDING | | DESIGN PRESSURE REQUIREMENT) FOR THE NEW DOOR, | | FBC1603.1.4. | | | | 2. FBC TABLE 715.4, FIRE RATED WALLS NOT SHOWN ON THE | | PLAN. PLEASE NOTE RATED WALLS (OCCUPANCY SEPARATION | | BETWEEN BUSINESS AND S2) AND SHOW COMPLIANCE FOR THE | | DOOR IF APPLICABLE. | | | | 3. PROVISO ITEM, SUBJECT TO FIELD INSPECTOR'S | | DISCRETION, A DETAIL PREPARED OR REVIEWED BY THE | | ARCHITECT FOR THE RAISED (EXISTING) DRAIN AND SLOPED | | CONCRETE TRANSITION MAY BE REQUIRED. | | | | 4. PROVISO ITEM, RE: A1, NOTE 5, "REMOVE AND REPLACE | | FIRE ALARM AND EMERGENCY DEVICES," ANY ALTERATIONS TO | | THE EXISTING FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE | | PERMIT AND REVIEW. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2010-11-08 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-11-08 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-11-08 |
Time |
11:24 |
Sent To |
B |
|
Notes |
2010-11-08 11:25:27 | 1400 CENTREPARK BOULEVARD | | PERMIT #10100535 | | | | SHEET A-2 INITIALED, STAMPED AND DATED. | | WJ | | WPBFR |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2010-11-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-11-04 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-11-04 |
Time |
14:03 |
Sent To |
|
|
Notes |
2010-11-04 14:04:17 | REVIEW WILL BE DONE AFTER SUBMISSION OF LIFE SAFETY | | PLAN | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
N |
Date |
2010-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-10-21 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-10-21 |
Time |
12:17 |
Sent To |
|
|
Notes |
2010-10-21 12:18:16 | PER CHIEF CARSILLO, ANY MODIFICATIONS TO THE CURRENT | | FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE | | PERMIT/REVIEW. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-10-27 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-10-27 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-10-27 |
Time |
13:55 |
Sent To |
|
|
Notes |
2010-10-27 13:57:01 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-10-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-10-21 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-10-20 |
Time |
14:34 |
Sent To |
|
|
Notes |
2010-10-20 14:35:59 | ******************EXPEDITED**************** | | GAVE TO SAM |
|
|