Plan Review Details - Permit 10100534
Plan Review Stops For Permit 10100534
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-02-02 Cont ID  
Sent By rmcdouga Date 2011-02-02 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2011-02-02 Time 13:59 Sent To  
Notes
2011-02-02 14:01:51PRODUCT APPROVALS FOR OWENS CORNING ASPHALT SHINGLES FL
 10674-R3 WERE SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-01-19 Cont ID  
Sent By rmcdouga Date 2011-01-19 Time 14:39 Rev Time 0.00
Received By rmcdouga Date 2011-01-19 Time 14:39 Sent To  
Notes
2011-01-19 15:53:402007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN EXPOSURE 'C' PER 2007
 FBC R301.2.1.4.3. PLEASE REVISE THE PLANS AND COMPONENT
 AND CLADDING PRESSURES ACCORDINGLY. (PREVIOUS COMMENT)
 THE COMPONENT AND CLADDING PRESSURES IN THE TABLE ON
 SHEET A2 HAVE NOT BEEN INCREASED BY THE HEIGHT AND
 EXPOSURE ADJUSTMENT COEFFICIENTS IN TABLE R301.2(3) FOR
 EXPOSURE C.
  
 2) THE PRODUCT REVIEW AFFIDAVIT FROM THE P.E. WILL NEED
 TO BE REVISED TO INCLUDE THE FIXED GLASS TRANSOM WINDOW
 AND THE INCREASED COMPONENT AND CLADDING PRESSURES.
  
 3) THE INSTALLATION SCHEDULE FOR THE STORM PANELS
 REQUESTED IN THE FIRST REVIEW IS INCOMPLETE. PLEASE
 SPECIFY THE WALL PRESSURES AND SHUTTER SPANS. THE GLASS
 SEPARATION IS NOT REQUIRED AS LONG AS THE SPAN
 LIMITATIONS IN THE PRODUCT APPROVAL ARE FOLLOWED PER
 THE PRODUCT APPROVAL. THE SUBSTRATE SPECIFIED ON THE
 SCHEDULE IS CBS. THE ANCHOR SPACING TABLES IN THE
 PRODUCT APPROVAL ARE FOR CONCRETE OR CONCRETE BLOCK.
 PLEASE SPECIFY WHICH ONE OF THESE SUBSTRATE TYPES THE
 ANCHORS WILL BE INSTALLED INTO.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-11-17 Cont ID  
Sent By rmcdouga Date 2010-11-17 Time 13:29 Rev Time 0.00
Received By rmcdouga Date 2010-11-03 Time 11:40 Sent To  
Notes
2010-11-17 13:29:572007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN EXPOSURE 'C' PER 2007
 FBC R301.2.1.4.3. PLEASE REVISE THE PLANS AND COMPONENT
 AND CLADDING PRESSURES ACCORDINGLY.
  
 2) PLEASE REVISE THE DESIGN INFORMATION ON SHEET A2 TO
 REFLECT ASCE 7-05 AND EXPOSURE C.
  
 3) PLEASE REVISE THE PRESSURES IN THE TABLE ON A2 AND
 UPDATE THE REFERENCE TO 2004 FBC TABLE 1609.6B TO 2007
 FBCR TABLE R301.2(2).
  
 4) SUBMIT TWO COPIES OF A ROOF FRAMING AND PERMANENT
 BRACING PLAN SPECIFYING THE ROOF TO WALL CONNECTIONS
 FROM THE DESIGNER OF RECORD FOR THE STRUCTURE AND
 SIGNED AND SEALED BY HIM.
  
 5) UPDATE THE MASONRY NOTES ON A3 FROM SBCCI TO FBC AND
 ACI 530 AND 531 FROM THE 1995 TO THE 2005 EDITION AS
 REFERENCED BY 2007 FBC CHAPTER 43.
  
 6) THE PRODUCT APPROVAL INSTALLATION INSTRUCTIONS FOR
 THE SINGLE HUNG WINDOWS REQUIRES 2X BUCKS AND THE PLANS
 SPECIFY 1X BUCKS. PLEASE CORRECT.
  
 7) THE MULLION PRODUCT APPROVAL SUBMITTED IS FOR
 HORIZONTAL APPLICATION TO MULL TRANSOMS OVER WINDOWS.
 THE PLANS DO NOT SHOW ANY WINDOWS WITH TRANSOMS ABOVE
 THEM. SUBMIT PRODUCT APPROVALS FOR VERTICAL ORIENTATION
 BETWEEN WINDOWS.
  
 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE FIXED
 TRANSOM WINDOW ABOVE THE DOUBLE ENTRY DOORS.
  
 9) SPECIFY THE SIZE OF THE TRANSOM WINDOW ABOVE THE
 DOUBLE ENTRY DOORS ON THE PLANS.
  
 10) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE
 STRUCTURAL MULLION BETWEEN THE ENTRY DOORS AND THE
 TRANSOM WINDOW ABOVE OR PROVIDE A DETAIL IF A POURED
 LINTEL OR STEEL BEAM IS USED.
  
 11) SUBMIT 2 COPIES OF AN INSTALLATION SCHEDULE AND KEY
 PLAN FOR THE STORM PANELS. SPECIFY THE CONN TYPE,
 SUBSTRATE, ANCHOR TYPE, ANCHOR SPACING, PANEL SPANS,
 ETC ON THE SCHEDULE.
 THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE
 DEVICES IS AVAILABLE ON THE CONSTRUCTION SERVICES
 WEBSITE UNDER PERMIT FORMS.
 HTTP://WWW.WPB.ORG/CONSTRUCTION/PERMITS_FORMS.PHP
  
 12) SUBMIT PRODUCT APPROVALS FOR THE TRUSS ANCHORS,
 CONNECTORS AND STRAPS OR LIST THERE FL#S OR NOAS ON THE
 PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2011-02-02 Cont ID  
Sent By rmcdouga Date 2011-02-02 Time 11:31 Rev Time 0.00
Received By rmcdouga Date 2011-02-02 Time 11:31 Sent To  
Notes
2011-02-02 11:32:37ELECTRICAL PROVISO
  
 PROVIDE TWO COPIES OF THE PANEL SCHEDULE PER NEC 408.4
 TO THE ELECTRICAL INSPECTOR AT THE FINAL INSPECTION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-01-19 Cont ID  
Sent By rmcdouga Date 2011-01-19 Time 08:54 Rev Time 0.00
Received By rmcdouga Date 2011-01-19 Time 08:54 Sent To  
Notes
2011-01-19 09:18:18ELECTRICAL PROVISO
  
 PROVIDE TWO COPIES OF THE PANEL SCHEDULE PER NEC 408.4
 TO THE ELECTRICAL INSPECTOR AT THE FINAL INSPECTION.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-11-03 Cont ID  
Sent By rmcdouga Date 2010-11-03 Time 11:39 Rev Time 0.00
Received By rmcdouga Date 2010-11-03 Time 09:04 Sent To  
Notes
2010-11-03 09:50:032007 FBC W/2009 REVISIONS
 2008 NEC
  
 ELECTRICAL REVIEW DENIED
  
 1) THE NAME AND LICENSE NUMBER OF THE PERSON
 RESPONSIBLE FOR THE ELECTRICAL DESIGN IS REQUIRED TO BE
 ON THE DRAWINGS. FS 471.003
  
 2) THE PLANS DO NOT COMPLY WITH 2008 NEC 210.52 FOR
 REQUIRED RECEPTACLE SPACING.
  
 3) SHOW COMPLIANCE WITH NEC 422.31 AND 422.32 FOR
 DISCONNECTING MEANS AT A/C COMPRESSOR AND OTHER MOTOR
 DRIVEN APPLIANCES OR PERMANENTLY CONNECTED APPLIANCES.
  
 4) SHOW COMPLIANCE WITH NEC 406.11 FOR TAMPER-RESISTANT
 RECEPTACLES.
  
 5) SHOW COMPLIANCE WITH NEC 210.12 (B) FOR ARC-FAULT
 CIRCUIT-INTERRUPTER PROTECTION IN FAMILY ROOMS, DINING
 ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS, HALLS AND OTHER
 SIMILAR ROOMS OR AREAS.
  
 6) NEC 210.8 REQUIRES ALL 125 -VOLT, SINGLE PHASE, 15-
 AND 20- AMPERE RECEPTACLES INSTALLED IN GARAGES TO HAVE
 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION. THE
 RECEPTACLE FOR THE GARAGE DOOR OPENER IS REQUIRED TO
 COMPLY.
  
 7) SHOW COMPLIANCE WITH FBC R313.4 WHICH REQUIRES
 CARBON MONOXIDE ALARMS WITHIN 10 FEET OF EACH ROOM USED
 FOR SLEEPING PURPOSES.
  
 8) A PANEL SCHEDULE IN COMPLIANCE WITH NEC 408.4 IS
 REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2011-06-28 Cont ID  
Sent By mgonzale Date 2011-06-28 Time 08:24 Rev Time 0.00
Received By mgonzale Date 2011-06-28 Time 08:24 Sent To  
Notes
2011-06-28 08:26:29PASSED
  
 PLAN SUBMITTED FOR DRIVEWAY AND APROACH IS ACCETABLE.
 NO CONFLICT WITH ANY CITY OF WPB PUBLIC UTILITIES.
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET,
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-01-18 Cont ID  
Sent By   Date 2011-01-18 Time   Rev Time 1.00
Received By   Date 2011-01-18 Time   Sent To  
Notes
2011-01-18 12:48:59PASSED WITH PROVISO:
  
 DRIVEWAY APPROACH MUST CONFORM TO CITY OF WPB STANDARD,
 A COPY OF THAT STANDARD HAS BEEN PROVIDED WITH YOUR
 PERMIT.
  
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-04-04 Cont ID  
Sent By jgomez Date 2011-04-04 Time 14:44 Rev Time 0.00
Received By jgomez Date 2011-04-04 Time 14:43 Sent To  
Notes
2011-04-04 14:45:03WINDOW REVISION SENT TO MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-01-26 Cont ID  
Sent By jgomez Date 2011-01-26 Time 14:03 Rev Time 0.00
Received By jgomez Date 2011-01-26 Time 14:02 Sent To  
Notes
2011-01-26 14:03:12SENT TO R. MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-12-10 Cont ID  
Sent By jgomez Date 2010-12-10 Time 13:42 Rev Time 0.00
Received By jgomez Date 2010-12-10 Time 13:42 Sent To  
Notes
2010-12-10 13:42:53SENT TO R3.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-01-19 Cont ID  
Sent By rmcdouga Date 2011-01-19 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2010-10-20 Time 13:54 Sent To  
Notes
2010-10-20 13:55:06B1

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-02-04 Cont ID  
Sent By rmcdouga Date 2011-02-04 Time 14:33 Rev Time 0.00
Received By rmcdouga Date 2011-02-04 Time 14:33 Sent To  
Notes
2011-02-04 14:37:25MU-2011-002089-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-11-03 Cont ID  
Sent By rmcdouga Date 2010-11-03 Time 11:39 Rev Time 0.00
Received By rmcdouga Date 2010-11-03 Time 11:39 Sent To  
Notes
2010-11-03 11:39:57IMPACT FEE REVIEW IS REQUIRED.

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2010-12-13 Cont ID  
Sent By rkussner Date 2010-12-13 Time 12:00 Rev Time 0.00
Received By rkussner Date 2010-12-13 Time 11:49 Sent To  
Notes
2010-12-13 12:01:34***LANDSCAPE REVIEW NOT REQUIRED***
  
 PLEASE REFER TO PERMIT #10110364 FOR LANDSCAPE PERMIT
 AND PLANS---RAK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-11-02 Cont ID  
Sent By rmcdouga Date 2010-11-02 Time 15:54 Rev Time 0.00
Received By rmcdouga Date 2010-11-02 Time 15:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2011-02-02 Cont ID  
Sent By rmcdouga Date 2011-02-02 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2011-02-02 Time 09:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2011-01-19 Cont ID  
Sent By rmcdouga Date 2011-01-19 Time 07:30 Rev Time 0.00
Received By rmcdouga Date 2011-01-19 Time 07:30 Sent To  
Notes
2011-01-19 07:58:192007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) THE PLUMBING RISER DIAGRAM ON A3 ONLY SHOWS ONE OF
 THE TWO LAVATORIES LOCATED IN THE MASTER BATHROOM.
 PLEASE REVISE THE DIAGRAM TO SHOW HOW THE SECOND
 LAVATORY IS CONNECTED TO THE BUILDING DRAIN AND HOW IT
 WILL BE VENTED.
  
 2) ON A3 THE VENT TO ROOF FOR THE WASHING MACHINE DRAIN
 IS SPECIFIED AS 2" ON THE PLUMBING RISER DIAGRAM AND 3"
 ON THE FLOOR PLAN. PLEASE COORDINATE THE VENT SIZE.
  
 3) ON A7 IN THE BUILDER NOTES AT THE BOTTOM OF THE
 ELECTRICAL SYMBOL LEGEND THERE IS A NOTE THAT STATES
 ALL PLUMBING SHALL COMPLY WITH THE 2004 FL PLUMBING
 CODE. PLEASE UPDATE THIS NOTE TO THE 2007 FL PLUMBING
 CODE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-11-02 Cont ID  
Sent By rmcdouga Date 2010-11-02 Time 08:45 Rev Time 0.00
Received By rmcdouga Date 2010-11-02 Time 08:45 Sent To  
Notes
2010-11-02 09:52:562007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) THE PLUMBING RISER DIAGRAM ON A3 IS MISSING THE
 MASTER BATH SHOWER. PLEASE CORRECT.
  
 2) THE WET VENT FOR BATH #2 DOES NOT COMPLY WITH FBCR
 P3108.2. IN HORIZONTAL WET-VENT SYSTEMS, NOT MORE THAN
 ONE WET-VENTED FIXTURE SHALL DISCHARGE UPSTREAM OF THE
 DRY-VENTED FIXTURE DRAIN CONNECTION.
  
 3) THE TUB IN BATH #2 IS INCORRECTLY LABELED AS A
 SHOWER. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2010-12-29 Cont ID  
Sent By lfranco Date 2010-12-29 Time 17:36 Rev Time 0.00
Received By lfranco Date 2010-12-29 Time 17:36 Sent To ENG
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-11-18 Cont ID  
Sent By lfranco Date 2010-11-18 Time 18:18 Rev Time 0.00
Received By lfranco Date 2010-11-18 Time 18:18 Sent To  
Notes
2010-11-18 18:44:25PLANNING AND ZONING: **** FAILED ****
  
  
 1. PLEASE RESPOND TO COMMENTS IN WRITING.
  
 2. PROVIDE PROPOSED BUILDING (STRUCTURE) ON THE SURVEY
 DEPICTING DIMENSIONS TO ALL PROPERTY LINES. THE REAR
 SETBACK IS NOT SHOWN.
  
 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED
 A/C/MECHANICAL EQUIPMENT TO ALL PROPERTY LINES.
 PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR:
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
 4. PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).
  
 5. PROVIDE TOTAL HEIGHT FROM FINISHED FLOOR TO FINISHED
 ROOF TOP ON SHEET WITH ELEVATIONS.
  
 6. A SEPARATE LANDSCAPE PERMIT IS REQUIRED. CONTACT
 ROBERT KUSSNER (LANDSCAPE PLANNER) @ 822-1462.
  
 SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR.
  
 7. A SEPARATE PERMIT FOR THE PROPOSED DRIVEWAY WILL BE
 REQUIRED FROM THE ENGINEERING DEPARTMENT THROUGH
 CONSTRUCTION SERVICES.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  
  