2010-10-29 09:48:35****PROVISO****
 ****REVISION REQUIRED****
  
 1. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B. FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE
 CHANGED EFFECTIVE MARCH 1, 2009.
  
 R301.2.1.4 EXPOSURE CATEGORY. FOR EACH WIND DIRECTION
 CONSIDERED, AN EXPOSURE CATEGORY THAT ADEQUATELY
 REFLECTS THE CHARACTERISTICS OF GROUND SURFACE
 IRREGULARITIES SHALL BE DETERMINED FOR THE SITE AT
 WHICH THE BUILDING OR STRUCTURE IS TO BE CONSTRUCTED.
 FOR A SITE LOCATED IN THE TRANSITION ZONE BETWEEN
 CATEGORIES, THE CATEGORY RESULTING IN THE LARGEST WIND
 FORCES SHALL APPLY. ACCOUNT SHALL BE TAKEN OF
 VARIATIONS IN GROUND SURFACE ROUGHNESS THAT ARISE FROM
 NATURAL TOPOGRAPHY AND VEGETATION AS WELL AS FROM
 CONSTRUCTED FEATURES. FOR ANY GIVEN WIND DIRECTION, THE
 EXPOSURE IN WHICH A SPECIFIC BUILDING OR OTHER
 STRUCTURE IS SITED SHALL BE ASSESSED AS BEING ONE OF
 THE FOLLOWING CATEGORIES:
  
 EXCEPTION: AN INTERMEDIATE EXPOSURE BETWEEN THE
 EXPOSURE CATEGORIES DEFINED IS PERMITTED IN A
 TRANSITION ZONE PROVIDED THAT IT IS DETERMINED BY A
 RATIONAL ANALYSIS METHOD.
  
 EITHER SUBMIT PLANS DESIGNED TO EXPOSURE C OR PROVIDE
 ANALYSIS FOR EXPOSURE C.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-12-09 Cont ID  
Sent By lmartine Date 2010-12-09 Time 13:06 Rev Time 0.00
Received By lmartine Date 2010-12-09 Time 13:06 Sent To  
Notes
2010-12-09 13:06:57IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-29 Cont ID  
Sent By shill Date 2010-10-29 Time 09:48 Rev Time 0.00
Received By shill Date 2010-10-04 Time 14:15 Sent To  
Notes
2010-10-04 14:16:04ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2010-12-16 Cont ID  
Sent By lfranco Date 2010-12-16 Time 17:28 Rev Time 0.00
Received By lfranco Date 2010-12-09 Time 16:40 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-10-19 Cont ID  
Sent By lfranco Date 2010-10-19 Time 09:28 Rev Time 0.00
Received By lfranco Date 2010-10-06 Time 17:12 Sent To B
Notes
2010-10-19 09:33:30PLANNING AND ZONING: **** FAILED *****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. A LETTER FROM THE HOME OWNER'S ASSOCIATION ("HOA")
 IS REQUIRED NOTING THAT THE SCREEN DOOR WILL BE ALLOWED
 WITHIN THE FRONT PROPERTY AREA, PRIOR TO APPROVAL BY
 THE PLANNING AND ZONING DEPARTMENT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  