Plan Review Details - Permit 10090739
Plan Review Stops For Permit 10090739
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-01-21 Cont ID  
Sent By jgomez Date 2011-01-21 Time 09:51 Rev Time 0.00
Received By jgomez Date 2011-01-21 Time 08:23 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2011-01-03 Cont ID  
Sent By jgomez Date 2011-01-03 Time 15:06 Rev Time 0.00
Received By jgomez Date 2011-01-03 Time 11:27 Sent To PC
Notes
2011-01-03 15:07:55BUILDING REVIEW THIRD CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- FLAT ROOF PRODUCT APPROVAL SUBMITTED:
 A) NOA 07-0730.03 SUBMITTED IS SUPERSEDED ALSO. GO TO
 THE MIAMI-DADE WEBSITE AND DOWNLOAD CURRENT NOA.
 B) REVISE SIGNED & SEALED RAS 117 CALCULATIONS TO
 REFERENCE UPDATED NOA.
  
 2- ENGINEER TO REVIEW/APPROVE UPDATED FLAT ROOF PRODUCT
 APPROVAL. SEC. 106.3.3 CITY AMENDMENTS.
  
 3- PROVIDE FRAMING DETAILS FOR NEW ATTIC ACCESS.
 REVISED SHEET S-2 SUBMITTED DOESN'T SHOW ANY DETAILS.
  
 4- SHEET A2.3:
 A) REVISE MODIFIED ROOFING SPECS ON PARAPET FLASHING
 DETAIL. BASE SHEET NAILING SPACING SHOWN DOESN'T MATCH
 RAS 117 CALCULATIONS. THIS DETAIL SPECIFIES DYNAFLEX
 MEMBRANE. SEE PRODUCT APPROVAL SUBMITTED AND REVISE AS
 REQUIRED. REVISE NOA SPECIFIED TO MATCH NEW UPDATED
 NOA. SELECTED ASSEMBLY DOESN'T HAVE INSULATION. REVISE
 AS REQUIRED.
  
 B) EXISTING ROOF: ROOF SLOPE WAS MODIFIED. PROVIDE
 CALCULATIONS TO SHOW THAT ONLY ONE SCUPPER IS ADEQUATE
 AND SHOW SECONDARY EMERGENCY SCUPPER. NOT REVISED.
 EXISTING ROOF ONLY SHOWS ONE SCUPPER AND THERE ARE NO
 EMERGENCY SCUPPERS SHOWN. ALSO, FLAT ROOF SPECS REFER
 TO "JOHNS MANVILLE" ROOFING SYSTEM. SEE PRODUCT
 APPROVAL SUBMITTED AND REVISE AS REQUIRED.
  
 5- REVISE SHEET A3.2. DETAIL 12/A5 KEYED ON PARAPETS
 AND HEADERS IS FOR WINDOW SILL DETAIL ON WOOD FRAMED
 WALL.
 SHEET A3.3 SUBMITTED ALSO SPECIFIES DETAIL 12/A5 ON
 PARAPET WALL. REVISE AS REQUIRED.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-12-09 Cont ID  
Sent By jgomez Date 2010-12-07 Time 16:06 Rev Time 0.00
Received By jgomez Date 2010-12-07 Time 16:06 Sent To HIST
Notes
2010-12-07 17:01:50BUILDING REVIEW APPROVED WITH PROVISO:
 1- FLAT ROOF PRODUCT APPROVAL SUBMITTED:
 A) NOA 07-0228.06 IS SUPERSEDED. NEED CURRENT NOA.
 B) IDENTIFY APPROVED ASSEMBLY TO BE USED.
 C) PROVIDE SIGNED & SEALED RAS 117 CALCULATIONS.
  
 2- ENGINEER TO REVIEW/APPROVE NEW FLAT ROOF PRODUCT
 APPROVAL. SEC. 106.3.3 CITY AMENDMENTS.
  
 3- PROVIDE FRAMING DETAILS FOR NEW ATTIC ACCESS.
  
 4- SPECIFY HOW OBTAINING R6 INSULATION ON THE MASONRY
 WALL. SEE ENERGY CALCULATIONS.
  
 5- SHEET A2.3:
 A) REVISE MODIFIED ROOFING SPECS ON PARAPET FLASHING
 DETAIL. SEE ITEM 1C ABOVE.
 B) EXISTING ROOF: ROOF SLOPE WAS MODIFIED. PROVIDE
 CALCULATIONS TO SHOW THAT ONLY ONE SCUPPER IS ADEQUATE
 AND SHOW SECONDARY EMERGENCY SCUPPER.
  
 6- NEW ATTIC SPACE WAS CREATED ON SECOND FLOOR:
 A) SPECIFY CEILING HEIGHT. SEC. R305.
 B) PROVIDE FRAMING DETAILS/SPECIFICATION FOR NEW HUNG
 CEILING. SEC. 106.1.1 CITY AMENDMENTS TO FBC.
  
 7- REVISE SHEET A3.2. DETAIL 12/A5 KEYED ON PARAPETS,
 LINTELS, HEADERS AND WINDOW SILLS IS FOR WINDOW SILL
 DETAIL ON WOOD FRAMED WALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-10-15 Cont ID  
Sent By jgomez Date 2010-10-15 Time 15:22 Rev Time 0.00
Received By jgomez Date 2010-10-15 Time 15:22 Sent To  
Notes
2010-10-15 15:23:58RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 OF THE
 2007 FLORIDA RESIDENTIAL CODE THIS BUILDING IS LOCATED
 ON EXPOSURE "C" NOT EXPOSURE "B". REVISE STRUCTURAL
 DRAWINGS AS REQUIRED. ENGINEER NEEDS TO REVISE THE
 DESIGN CRITERIA AND THE COMPONENTS AND CLADDING DESIGN
 PRESSURES ON THE STRUCTURAL DRAWINGS.
  
 2- ENGINEER NEEDS TO INCREASE 20% ON THE ROOF SHEATHING
 AND ROOF-TO-WALL UPLIFT LOADS AS REQUIRED BY 2009
 REVISIONS SEC. R301.2.1.4.3(2).
  
 3- BRING PLANS TO THE HISTORIC DEPARTMENT FOR HISTORIC
 APPROVAL STAMP BEFORE SUBMITTING THEM TO THIS OFFICE.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 (A) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. PRODUCT
 APPROVAL SUBMITTED IS FOR FIXED WINDOWS. THERE ARE NOT
 FIXED WINDOWS SHOWN ON PLANS. AND, NOA 08-1112.10
 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE.
  
 (B) SLIDING WINDOWS AS SHOWN ON PLANS.
  
 (C) FLAT ROOF SYSTEM TO BE USED: (1 )NOA SPECIFIED ON
 ROOF FRAMING PLAN IS NOT THE SAME NOA THAT WAS
 SUBMITTED. AND, IT CAN'T BE USED BECAUSE IT WAS
 SUPERSEDED BY MIAMI-DADE. REVISE PLANS AND PRODUCT
 APPROVAL TO MATCH. SEE MIAMI-DADE WEBSITE FOR CURRENT
 PRODUCT APPROVALS.
 (2) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING
 TO BE USED.
 (3) PROVIDE RAS 117 CALCULATIONS AS REQUIRED BY GENERAL
 LIMITATION #7. IF NOA SUBMITTED REQUIRES SIGNED AND
 SEALED RAS 117 CALCULATIONS, THEN PROVIDE SIGNED AND
 SEALED CALCULATIONS.
 (4) DESIGN PROFESSIONAL DOING THE RAS 117 CALCULATIONS
 TO TAKE INTO CONSIDERATION THAT THIS BUILDING IS
 LOCATED ON EXPOSURE "C".
 (5) FLAT ROOF NOA 07-0730.03 SUBMITTED WAS SUPERSEDED
 BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA. SEE
 MIAMI-DADE WEBSITE. AND PROVIDE RAS 117 CALCULATIONS.
 SEE ITEM (C)(3) ABOVE.
  
 (D) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 (E) SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS.
  
 (F) EXTERIOR DOORS AS SHOWN ON PLANS.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 6- PROVIDE WINDOW CUT SHEETS SHOWING THAT 36"X56"
 SINGLE HUNG WINDOW MEET THE MIN. CLEAR OPENING REQUIRED
 OPENING AREA TO BE 5.7 S.FS AS REQUIRED BY SEC.
 R310.1.1 AND R310.1.2 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 7- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.
  
 8- SPECIFY CARBON MONOXIDE ALARMS ON PLANS AS REQUIRED
 BY 2009 REVISIONS SEC. R313.4 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 9- REVISE OVERFLOW SCUPPERS SHOWN ON SHEET A2.3 TO
 COMPLY WITH SEC. R903.4.1 OF 2007 FLORIDA RESIDENTIAL
 CODE. REVISE LOCATION OF MAIN SCUPPERS AND OVERFLOW
 SCUPPER IN RELATION TO THE ROOF FINISH. SEE SEC. R903.4
 AND R903.4.1.
  
 10- SPECIFY ROOF VENTILATION AS REQUIRED BY SEC. R806.
  
 11- CLARIFY HOW INSTALLING R-30 BUTT INSULATION ON ROOF
 DECK. AS SHOWN ON WALL SECTIONS AND DETAILS ON SHEET
 A3.2 AND A3.3. REVISE AS REQUIRED.
  
 12- REVISE STUCCO THICKNESS ON WOOD FRAMED WALLS NEED
 7/8" MIN. THICKNESS. SEE TABLE R702.1(1). REVISE ALL
 WALL SECTIONS AND WALL LEGEND SPECIFICATIONS.
  
 13- PROPOSED 2ND FLOOR PLAN ON SHEET A2.1 SHOWS 2'X3'
 ATTIC ACCESS. THIS IS A FLAT ROOF. CLARIFY/REVISE AS
 REQUIRED.
  
 14- PARTIAL SECOND FLOOR PLAN ON SHEET S2 SHOWS BEAMS
 RUNNING THRU CHASE OF EXISTING CHIMNEY. PROVIDE DETAILS
 AND SPECIFICATIONS SHOWING COMPLIANCE WITH SEC
 R1001.11. AND, THE FIREBLOCKING AND DRAFSTOPPPING
 REQUIREMENTS.
  
 15- REVISE ALL WALL SECTIONS AND WALL SCHEDULE
 SPECIFICATIONS TO SPECIFY 2 LAYERS OF WATER RESISTANT
 BARRIERS AS REQUIRED BY SEC. R703.6.3.
  
 16- ENERGY CALCULATIONS:
 A) ITEM #8 IS MISSING THE COMMON FLOOR. THIS IS A 2
 STORY ADDITION.
 B) CLARIFY HOW OBTAINING R6 INSULATION ON THE MASONRY
 WALL. AND, COORDINATE WITH INFORMATION SHOWN ON PLANS.
 C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
 D) COMPLETE ALL THE INFORMATION ON TOP OF THE FORM.
 E) COORDINATE R VALUE SHOWN ON ITEM #9(2) WITH
 INFORMATION SHOWN ON PLANS.
 F) REVISE ITEM #10. THERE IS NOT ATTIC ON THIS HOUSE.
 SEE PLANS.
 G) COMPLETE ALL THE INFORMATION ON TABLES 11B-1 AND
 11B-2 ON SHEET 2.
  
 17- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-12-08 Cont ID  
Sent By rlecky Date 2010-12-08 Time 14:42 Rev Time 0.00
Received By rlecky Date 2010-12-08 Time 14:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-10-06 Cont ID  
Sent By dwise Date 2010-10-06 Time 17:47 Rev Time 0.00
Received By dwise Date 2010-10-06 Time 17:47 Sent To  
Notes
2010-10-06 18:11:46ELECTRICAL PLAN REVIEW
 PERMIT #10090739
  
  
 REVIEW
 ACTION FAIL
 1) ELECTRIC PLAN SHOWS TO MOVE EXISTING PANEL INTO NEW
 MASTER BEDROOM CLOSET
 ARTICLE 240.24(2)(D) 2008 NEC
 2) PLAN SHOWS SMOKE DECTOR IN AREA OF SECOND FLOOR ATIC
 ACCESS
 3) PLAN SHOWS RECESS LIGHTING LUMINAIR IN AREA OF
 SECONED FLOOR ATIC ACCESS AREA
  
 JOHN DICKINSON CONTRACT PLAN REVEIWER LICENSE MUMBER PX
 3182
 CELL PHONE NUMBER 561 718 3230

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2010-12-08 Cont ID  
Sent By jgomez Date 2010-12-08 Time 10:31 Rev Time 0.00
Received By jgomez Date 2010-12-08 Time 10:30 Sent To  
Notes
2010-12-08 10:32:35APPROVED WITH PROVISO:
  
 1-SEPARATE GAS PERMIT REQUIRED. CONTRACTOR TO PROVIDE
 GAS PIPING ISOMETRIC AND ALL THE REQUIRED INFORMATION
 AND CALCULATIONS AT TIME OF PERMIT APPLICATION.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2010-10-22 Cont ID  
Sent By jgomez Date 2010-10-21 Time 15:56 Rev Time 0.00
Received By jgomez Date 2010-10-21 Time 15:56 Sent To  
Notes
2010-10-21 16:00:52RESIDENTIAL (R3) ADDITION/RENOVATION GAS REVIEW
 CHECKLIST.
  
 1- PROVIDE COMPLETE INFORMATION ON THE ISOMETRIC
 DRAWING AND PROVIDE ALL CALCULATIONS AS REQUIRED BY THE
 CITY POLICY FOR ALL GAS PERMIT APPLICATIONS.
  
 2- SEPARATE GAS PERMIT REQUIRED. ALL THE REQUIRED
 INFORMATION MAY BE PROVIDED WHEN APPLYING FOR THE
 SEPARATE GAS PERMIT.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2011-01-20 Cont ID  
Sent By jpapa Date 2011-01-20 Time 15:10 Rev Time 0.00
Received By jpapa Date 2011-01-20 Time 15:10 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2010-12-09 Cont ID  
Sent By jpapa Date 2010-12-09 Time 14:48 Rev Time 0.00
Received By jpapa Date 2010-12-09 Time 14:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2010-12-28 Cont ID  
Sent By jgomez Date 2010-12-28 Time 15:40 Rev Time 0.00
Received By jgomez Date 2010-12-28 Time 15:40 Sent To B
Notes
2010-12-28 15:40:40SENT TO J. GOMEZ' DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2010-12-10 Cont ID  
Sent By jgomez Date 2010-12-10 Time 09:42 Rev Time 0.00
Received By jgomez Date 2010-12-10 Time 09:42 Sent To PC
Notes
2010-12-10 09:43:07PLANS BACK FROM HISTORIC FOR PROCESSING.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-12-09 Cont ID  
Sent By jgomez Date 2010-12-09 Time 09:53 Rev Time 0.00
Received By jgomez Date 2010-12-09 Time 09:53 Sent To HIST
Notes
2010-12-09 09:55:00SENT PLANS J. PAPA DESK. CONTRACTOR DIDN'T DO IT BEFORE
 RE-SUBMITTAL AS REQUESTED ON PREVIOUS CHECKLIST.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-11-16 Cont ID  
Sent By lmartine Date 2010-11-16 Time 15:40 Rev Time 0.00
Received By lmartine Date 2010-11-16 Time 15:40 Sent To  
Notes
2010-11-16 15:40:54GAVE TO JULIO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-10-21 Cont ID  
Sent By jgomez Date 2010-10-21 Time 15:55 Rev Time 0.00
Received By jgomez Date 2010-09-29 Time 11:29 Sent To  
Notes
2010-09-29 11:30:19INCOMING SENT TO R-11

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2010-12-07 Cont ID  
Sent By jgomez Date 2010-12-07 Time 10:39 Rev Time 0.00
Received By jgomez Date 2010-12-07 Time 10:38 Sent To  
Notes
2010-12-07 10:41:12NO FEES. IMPACT FEES REVIEWED AND STAMPED BY VAL. ON
 11/4/10.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-10-15 Cont ID  
Sent By jgomez Date 2010-10-15 Time 12:37 Rev Time 0.00
Received By jgomez Date 2010-10-15 Time 12:37 Sent To  
Notes
2010-10-15 12:39:051- BRING PLANS TO PALM BEACH COUNTY. (2300 N. JOG RD)
 TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-12-08 Cont ID  
Sent By jgomez Date 2010-12-08 Time 16:43 Rev Time 0.00
Received By jgomez Date 2010-12-08 Time 16:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-10-22 Cont ID  
Sent By jgomez Date 2010-10-21 Time 15:55 Rev Time 0.00
Received By jgomez Date 2010-10-21 Time 15:55 Sent To  
Notes
2010-10-22 10:32:17RESIDENTIAL (R3) ADDITION/RENOVATION MECHANICAL REVIEW
 CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE COOLING AND HEATING LOAD CALCULATIONS AS
 REQUIRED BY SEC. N1107 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 ***NOTE: NO RETURN AIR ALLOWED FROM CLOSET OR BATHROOM.
 RETURN AIR TO BE DUCTED AS SHOWN ON SECOND FLOOR PLAN
 ON SHEET M1 AND DETAIL ON SHEET M2.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-12-08 Cont ID  
Sent By jgomez Date 2010-12-08 Time 16:50 Rev Time 0.00
Received By jgomez Date 2010-12-08 Time 16:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-10-22 Cont ID  
Sent By jgomez Date 2010-10-21 Time 15:55 Rev Time 0.00
Received By jgomez Date 2010-10-21 Time 15:55 Sent To  
Notes
2010-10-22 10:44:32RESIDENTIAL (R3) ADDITION/RENOVATION PLUMBING REVIEW
 CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PLUMBING RISER DIAGRAM AND PLUMBING FLOOR PLANS
 DON'T MATCH. REVISE AS REQUIRED TO MATCH TO VERIFY
 COMPLIANCE WITH THE 2007 FLORIDA RESIDENTIAL CODE.
  
 2- SPECIFY SIZE OF ALL DRAIN PIPES AND SPECIFY ALL
 CLEAN OUTS. SEC. P3005.2 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 1 Status P Date 2010-10-15 Cont ID  
Sent By astelly Date 2010-10-15 Time 06:58 Rev Time 0.00
Received By astelly Date 2010-10-15 Time 06:58 Sent To  
Notes
***NONE***