Plan Review Details - Permit 10090580
Plan Review Stops For Permit 10090580 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-11-22 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-11-22 |
Time |
11:56 |
Sent To |
|
|
Notes |
2010-11-22 12:27:03 | 7501 NORTH JOG ROAD | | SWA WEST BAGHOUSE | | PERMIT #10090580 | | | | PROVIDE CHECK VALVE FOR FIRE DEPARTMENT CONNECTION. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-10-01 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-10-01 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-10-01 |
Time |
09:52 |
Sent To |
|
|
Notes |
2010-10-01 10:15:19 | 7501 NORTH JOG ROAD | | PERMIT NUMBER 10090580 | | "FIRE HOSE STATIONS IN WEST BAGHOUSE INCLUDING 6" | | UNDERGROUND SUPPLY" | | | | | | 1. PLEASE PROVIDE AN ELEVATION DRAWING FOR THE | | STANDPIPE SYSTEM TO INCLUDE HOSE CABINETS. | | | | 2. PLEASE PROVIDE A DETAIL DRAWING OF THE HOSE CABINETS | | THAT ARE PLANNED TO BE USED. | | | | 3. PLEASE PROVIDE DETAILS ON PRESSURE TESTING AND | | FLUSHING REQUIREMENTS FOR THE NEW SYSTEM TO INCLUDE THE | | UNDERGROUND FIRE MAIN AND THE FIRE DEPARTMENT | | CONNECTION. | | | | 4. PLEASE PROVIDE DETAILS ON THE HOSE AND NOZZLES | | PLANNED FOR USE. WHO AND WHY DETERMINED THAT THE LENGTH | | OF HOSE BE 75 FEET. IS THE HOSE RED-LINE, COTTON | | JACKETED, OR OTHER TYPES OF FIRE HOSE. | | | | 5. WHY IS THE BUILDING NOT FIRE SPRINKLER PROTECTED? | | | | 6. THE FIRE DEPARTMENT CONNECTION IS TO BE EQUIPPED | | WITH KNOX LOCKING CAPS. THEY CAN BE ORDERED AT | | WWW.KNOXBOX.COM. | | | | 7. PLEASE INDICATE PRESSURE, GALLONS PER MINUTE (GPM) | | AND DURATION OF WATER THAT CAN BE EXPECTED FROM THE | | STANDPIPE SYSTEM. | | | | 8. PLEASE DISPLAY A RISER ELEVATION. | | | | 9. PLEASE INDICATE METHODS OF PIPE RESTRAINTS FOR THE | | SYSTEM. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-11-22 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-11-22 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-11-22 |
Time |
11:56 |
Sent To |
FIRE |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-11-03 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-11-03 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-09-22 |
Time |
08:34 |
Sent To |
|
|
Notes |
2010-09-22 08:34:40 | IN FIRE BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-10-27 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-10-27 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-10-27 |
Time |
08:23 |
Sent To |
|
|
Notes |
|
|
|