Plan Review Details - Permit 10090185
Plan Review Stops For Permit 10090185 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-10-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-05 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-05 |
Time |
08:45 |
Sent To |
|
|
Notes |
2010-10-05 08:47:14 | REVISED SHEETS D1, A1.O AND S2.O HAVE BEEN REVIEWED FOR | | CODE COMPLIANCE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-01-06 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2011-01-06 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2011-01-06 |
Time |
08:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-09-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2010-09-29 |
Time |
07:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-09-29 |
Time |
07:55 |
Sent To |
|
|
Notes |
2010-09-29 08:47:42 | BRANCH CIRCUITS SHALL COMPLY WITH 210.12 B | | | | ALL RECEPTACLE OUTLETS SHALL BE TAMPER RESISTANT. | | 406.11 | | | | MEANS SHALL BE PROVIDED FOR BONDING/GROUNDING OTHER | | SYSTEMS AT THE SERVICE 250.94 | | | | OUTDOOR OUTLETS SHALL BE WEATHER RESISTANT. 406.8 | | | | DESCRIPTION OF BRACH CIRCUITS NEED TO BE MORE SPECIFIC, | | 408.4 | | | | OUTLET SPACING AS SHOWN ON DRAWINGS DOES NOT MEET THE | | SPACING REQUIREMENTS OF 210.52 A 1,2 | | KITCHEN COUNTER, HALLWAY,BEDROOMS ALL HAVE OUTLET | | SPACING VIOLATIONS. | | | | NO COMPRESSOR CIRCUIT SHOWN ON PANEL SCHEDULE OR | | DRAWING (LOCATION) | | | | EMERGENCY PANEL SCHEDULE NOT SHOWN. | | | | NEED SIZE OF PANEL SIZE OF WIRE, LISTING ON GENERATOR | | RECEPTACLE (EMERGENCY SYSTEM) | | | | OULETS ON OUTSIDE WALLS THAT ARE FACING OUTDOORS SHALL | | BE CONSIDERED A WET/DAMP LOCATION SEE 334.12 B 4 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-01-03 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-01-03 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-01-03 |
Time |
13:28 |
Sent To |
|
|
Notes |
2011-01-03 13:28:46 | GAVE TO JAKE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-10-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-05 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-09-08 |
Time |
16:56 |
Sent To |
|
|
Notes |
|
|
|