Plan Review Stops For Permit 10090165 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2011-01-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:09 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-12-09 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-12-09 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-11-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-11-15 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-11-15 |
Time |
13:37 |
Sent To |
|
|
Notes |
2010-11-15 15:37:29 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) SUBMIT 2 COPIES OF CURRENT PRODUCT APPROVALS FOR THE | | HORIZONTAL SLIDING WINDOWS. THE ONES THAT WERE | | SUBMITTED HAVE BEEN REVISED BY NOA NO.09-1008.06. | | | | 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | NEW SINGLE HUNG WINDOWS HAVE A MAXIMUM DESIGN PRESSURE | | OF POSITIVE AND NEGATIVE 60 PSI. THE WINDLOAD | | CALCULATIONS THAT WERE SUBMITTED SHOW THAT THE WINDOWS | | LOCATED IN WALL ZONE 5 HAVE NEGATIVE PRESSURES IN | | EXCESS OF NEGATIVE 60 PSI. SUBMIT PRODUCT APPROVALS FOR | | WINDOWS WITH A DESIGN PRESSURE OF MORE THAN - 63.7 PSI. | | | | 3) FBC R703.6.3 REQUIRES A BOND BREAK BETWEEN THE | | EXTERIOR STUCCO AND THE WATER-RESISTIVE BARRIER. SHOW | | COMPLIANCE. | | | | 4) THE EXTERIOR WALL DETAIL DOES NOT SPECIFY THE CLIPS | | OR STRAPS THAT WILL BE USED TO ATTACH THE STUDS TO THE | | TOP AND BOTTOM PLATES OR THE TRUSSES TO THE WALL. | | PLEASE REVISE THE DETAIL. | | | | 5) THE GUIDELINES FOR HURRICANE RESISTANT CONSTRUCTION | | REQUIRES WALL BOTTOM PLATES TO BE ANCHORED TO THE | | FOUNDATION WITH A MINIMUM 5/8" DIAMETER BOLT AND 3 ' X | | 3" X 1/8" WASHERS WITH A MINIMUM EMBEDMENT OF 7" IN | | CONCRETE WITH MAXIMUM SPACING OF 1-1/2 FT. PLEASE | | REVISE THE DETAIL. | | | | 6) THE PLANS SPECIFY R-19 INSULATION IN THE EXTERIOR 2 | | X 4 FRAME WALLS. R-19 REQUIRES A 2 X 6 FRAME WALL. THE | | ENERGY FORM ALLOWS R-13 WALL INSULATION IN 2 X 4 WALLS. | | PLEASE REVISE. | | | | 7) BECAUSE STORAGE SPACE IS BEING CONVERTED INTO LIVING | | SPACE, THE PLANS WILL BE REQUIRED TO BE REVIEWED BY | | PALM BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES WILL | | BE REQUIRED. THIS CAN BE DONE AFTER ALL OF THE REVIEWS | | HAVE BEEN PASSED. | | | | 8) THE ZONING COMMENTS STATE THAT THE GARAGE CAN NOT BE | | CONVERTED INTO ANOTHER DWELLING UNIT WITH A KITCHEN. | | THE PLANS WILL NEED TO BE REVISED TO SHOW COMPLIANCE | | WITH THE ZONING COMMENTS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-10-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-05 |
Time |
11:10 |
Sent To |
|
|
Notes |
2010-10-12 15:41:41 | DENIED BY BUILDING | | | | 1) SPECIFY THE NAME AND LICENSE NUMBER OF THE PERSON | | RESPONSIBLE FOR THE DESIGN ON THE PLANS. IF PERSON IS | | LICENSED UNDER FS 471 OR 481, THEN APPROPRIATE SEALS | | AND SIGNATURES ARE REQUIRED. | | | | 2) PROVIDE A FLOOR PLAN SHOWING THE EXISTING FIRST | | FLOOR AND A SEPARATE FLOOR PLAN SHOWING THE PROPOSED | | CHANGES. | | | | 3) PROVIDE SQUARE FEET AREA OF EXISTING FIRST FLOOR | | LIVING SPACE AND GARAGE AREA AND THE TOTAL AMOUNT | | LIVING SPACE AFTER CHANGES. | | | | 4) PROVIDE DETAILS FOR THE EXTERIOR WALLS AT THE NEW | | WASHER/DRYER ENCLOSURE AND THE IN-FILL AT THE EXISTING | | GARAGE DOOR OPENING. SPECIFY FRAMING MATERIAL, ANCHORS, | | STRAPS, INSULATION, INTERIOR FINISH AND EXTERIOR | | FINISH. | | | | 5) PROVIDE DETAILS OF THE EXTERIOR EGRESS STAIRS THAT | | ARE BEING REPLACED. SHOW COMPLIANCE WITH FBC R311.5 | | STAIRWAYS, R312 GUARDS AND R301.5 LIVE LOAD. | | | | 6) THE CONDITIONED FIRST FLOOR AREA ON THE ENERGY | | CALCULATION FORM IS 336 SQFT AND ON THE PLANS IT IS 510 | | SQFT. PLEASE CLARIFY. | | | | 7) THE PLANS SPECIFY THE OCCUPANCY AS R-2. BECAUSE THIS | | IS A TWO UNIT RESIDENCE, IT IS CONSIDERED AN R-3 | | OCCUPANCY. PLEASE REVISE PLANS. | | | | 8) SUBMIT TWO COPIES OF CURRENT PRODUCT APPROVALS FOR | | THE IMPACT RATED HORIZONTAL SLIDING WINDOW IN BEDROOM | | #2 AND THE EXTERIOR DOUBLE DOORS AT THE NEW LAUNDRY | | ROOM AS REQUIRED BY DCA RULE 9B-72. | | | | 9) SUBMIT TWO COPIES OF CURRENT PRODUCT APPROVALS FOR | | THE IMPACT RATED SINGLE HUNG WINDOWS. THE ONES THAT | | WERE SUBMITTED HAVE BEEN SUPERSEDED BY NOA NO. | | 09-0916.05 AND ARE NO LONGER CURRENT. | | | | 10) BECAUSE THE EXISTING GARAGE IS BEING CONVERTED TO | | LIVING SPACE, THE PLANS WILL NEED AN IMPACT FEE REVIEW | | BY PALM BEACH COUNTY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-01-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-09-30 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2010-09-30 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2010-09-30 |
Time |
17:18 |
Sent To |
|
|
Notes |
2010-09-30 17:19:44 | OK PER JOHN DICKINSON LICENSE NUMBER PX3182 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2011-01-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-01-20 |
Time |
07:46 |
Sent To |
|
|
Notes |
2011-01-20 07:46:31 | TO R MCDOUGAL'S DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-12-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-12-09 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-11-30 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-10-27 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-10-27 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-10-27 |
Time |
13:38 |
Sent To |
|
|
Notes |
2010-10-27 13:40:40 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-10-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-09-08 |
Time |
17:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2011-01-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-01-24 |
Time |
14:10 |
Sent To |
|
|
Notes |
2011-01-24 14:11:54 | THE SCOPE OF WORK WAS CHANGED TO REMOVE THE CONVERSION | | OF THE GARAGE TO LIVING SPACE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2010-11-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-11-15 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-11-15 |
Time |
13:37 |
Sent To |
|
|
Notes |
2010-11-15 13:39:14 | A PALM BEACH COUNTY IMPACT FEE REVIEW IS REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2010-10-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:09 |
Sent To |
|
|
Notes |
2010-10-13 10:11:32 | NO MECHANICAL PLANS WERE SUBMITTTED AND NO MECHANICAL | | PERMIT WAS APPLIED FOR. SEPARATE APPLICATION AND PLANS | | ARE REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2010-10-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-13 |
Time |
10:11 |
Sent To |
|
|
Notes |
2010-10-13 10:12:36 | NO PLUMBING PLANS WERE SUBMITTTED AND NO PLUMBING | | PERMIT WAS APPLIED FOR. SEPARATE APPLICATION AND PLANS | | ARE REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2011-01-27 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2011-01-27 |
Time |
18:11 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2011-01-25 |
Time |
17:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2011-01-10 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2011-01-10 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2011-01-10 |
Time |
17:28 |
Sent To |
B |
|
Notes |
2011-01-10 17:33:39 | PLANNING AND ZONING: **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. PURSUANT TO SECTION 94-72 OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS ("ZELDA"), THE SCOPE OF WORK | | SHOWING THE ADDITIONAL LIVING SPACE WITH KITCHEN | | (DWELLING UNIT) IN THE FIRST FLOOR OF THE ACCESSORY | | UNIT (GARAGE CONVERSION) IS NOT ALLOWED IN A SINGLE | | FAMILY LOW RESIDENTIAL ("SF7") ZONING DISTRICT, IT | | EXCEEDS THE ALLOWABLE DWELLING UNITS OF ONE (1) SINGLE | | FAMILY. THE ADDITIONAL REMODELING WORK FOR THE | | ACCESSORY UNIT WILL BE ALLOWED. HOWEVER, THE SCOPE OF | | WORK WILL NEED TO BE REVISED TO OMIT ALL REFERENCE, | | DRAWINGS OF THE LIVING SPACE CONVERSION IN THE GARAGE, | | SO THAT THE REMAINDER OF THE WORK CAN BE REVIEWED | | ACCORDINGLY. | | | | RE: THE CONTRACTOR (WILLIE HCD) MET WITH PLANNING STAFF | | AND BUILDING (ROBERT MCDOUGAL), AND NOTED THAT THE | | PLANS WILL HAVE TO CHANGE TO ADDRESS THE PLANNING | | COMMENTS TO OMIT SCOPE OF WORK FOR THE GARAGE | | CONVERSION AND DELETE ELECTRIC METER. ROBERT MCDOUGAL | | FILED THE PLANS AND UNDER FAILED. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2010-11-08 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-11-05 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-10-29 |
Time |
10:53 |
Sent To |
B |
|
Notes |
2010-11-08 18:55:39 | PLANNING AND ZONING: **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. PURSUANT TO SECTION 94-72 OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS ("ZLDR"), THE SCOPE OF WORK | | SHOWING THE ADDITIONAL LIVING SPACE WITH KITCHEN | | (DWELLING UNIT) IN THE FIRST FLOOR OF THE ACCESSORY | | UNIT (GARAGE CONVERSION) IS NOT ALLOWED IN A SINGLE | | FAMILY LOW RESIDENTIAL ("SF7") ZONING DISTRICT, IT | | EXCEEDS THE ALLOWABLE DWELLING UNITS OF ONE (1) SINGLE | | FAMILY. THE ADDITIONAL REMODELING WORK FOR THE | | ACCESSORY UNIT WILL BE ALLOWED. HOWEVER, THE SCOPE OF | | WORK WILL NEED TO BE REVISED TO OMIT ALL REFERENCE, | | DRAWINGS OF THE LIVING SPACE CONVERSION IN THE GARAGE, | | SO THAT THE REMAINDER OF THE WORK CAN BE REVIEWED | | ACCORDINGLY. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-10-05 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-10-05 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-10-05 |
Time |
09:57 |
Sent To |
|
|
Notes |
2010-10-05 10:00:58 | PLANNING AND ZONING: **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | 3. WHERE IS THE EXISTING GARAGE? PROVIDE FLOOR PLAN OF | | SCOPE OF WORK FOR THE CONVERSION. NOT ENOUGH | | INFORMATION WAS PROVIDED TO PERFORM REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | | | |
|
|