Plan Review Details - Permit 10090070
Plan Review Stops For Permit 10090070
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-03-01 Cont ID  
Sent By jwitmer Date 2011-03-01 Time 08:50 Rev Time 0.55
Received By jwitmer Date 2011-03-01 Time 08:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-01-05 Cont ID  
Sent By jwitmer Date 2011-01-05 Time 14:12 Rev Time 0.50
Received By jwitmer Date 2011-01-05 Time 13:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-09-09 Cont ID  
Sent By jwitmer Date 2010-09-09 Time 10:25 Rev Time 0.77
Received By jwitmer Date 2010-09-09 Time 10:25 Sent To  
Notes
2010-09-09 10:32:31BUILDING PLAN REVIEW
 PERMIT: 10090070
 ADD: 4310 BROADWAY
 CONT: J & M CONTRACTORS
 TEL: (561)718-7040
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION INDICATES THE SCOPE OF WORK
 FOR THIS PERMIT IS TO BUILD A NEW ADA SERVICE COUNTER,
 WHERE AS THE PLANS INDICATE THE INCREASING OF THE
 HEIGHT OF THE PARAPET. THERE ARE OTHER APPLIED FOR
 PERMITS FOR NEW EXHAUST HOOD, AND A SEPARATE PERMIT
 WILL BE REQUIRED FOR THE WALK IN COOLER. IT APPEARS A
 NEW COMMERCIAL KITCHEN IS THE SCOPE OF WORK TO BE
 DESCRIBED UNDER THIS PERMIT. ADDITIONAL INFORMATION
 REQUIRED.
  
 2) SHEET M-1 INDICATES A NEW PARAPET WALL FOUR FEET IN
 HEIGHT, IS THIS NEW WALL SURROUND THE BUILDING ON ALL
 FOUR SIDES? 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 3) THE PLANS, SHEET M-1 INDICATES A NEW ROOF TOP
 EXHAUST FAN, PLEASE PROVIDE A CURB DETAIL HOW IT WILL
 BE ANCHORED TO THE EXISTING ROOFING ASSEMBLY. FBC-B
 1609/ 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 4) THE NEW ROOF TOP EXHAUST FAN WILL NEED PRODUCT
 APPROVALS AND ASSOCIATED PRESSURES IT WILL WITHSTAND.
 NOTE THIS SHOULD BE REVIEWED BY THE DESIGN PROFESSIONAL
 BEFORE BEING SUBMITTED TO THE BUILDING DEPARTMENT.
 FBC-B 1609. 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5) A-1 INDICATES BOTH THE FRONT AND REAR DOOR HAVING A
 CHANGE IN GRADE GREATER THAN ?? INCH. PLEASE REVIEW
 11-4.5.2 CHANGES IN LEVEL. CHANGES IN LEVEL UP TO 1/4
 INCHES (6 MM) MAY BE VERTICAL AND WITHOUT EDGE
 TREATMENT [SEE FIGURE 7(C)]. CHANGES IN LEVEL BETWEEN
 1/4 INCH AND 1/2 INCH (6 MM AND 13 MM) SHALL BE BEVELED
 WITH A SLOPE NO GREATER THAN 1:2 [SEE FIGURE 7(D)].
 CHANGES IN LEVEL GREATER THAN 1/2 INCH (13 MM) SHALL BE
 ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH
 SECTION 11-4.7 OR 11-4.8.
  
 6) THIS APPEARS TO BE A CHANGE OF OCCUPANCY REQUIRING
 PALM BEACH COUNTY IMPACT FEE ASSESSMENT. BEFORE A
 PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE
 PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE
 PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE
 CALL (561)233-5025 FOR MORE INFORMATION.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2011-02-28 Cont ID  
Sent By rlecky Date 2011-02-28 Time 15:26 Rev Time 0.00
Received By rlecky Date 2011-02-28 Time 15:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2011-01-13 Cont ID  
Sent By rlecky Date 2011-01-13 Time 08:50 Rev Time 0.00
Received By rlecky Date 2011-01-12 Time 14:25 Sent To  
Notes
2011-01-12 14:39:05ELECTRIC PERMIT REQUIRED.
 REVISE SCOPE OF WORK AND VALUE TO REFLECT NEW ELECTRIC
 WORK
 UPDATE PERMIT FEE TO REFLECT VALUE OF WORK
 PROVIDE SIGN CIRCUIT. NEC 600.5
 PROVIDE A BONDING BAR AT THE SERVICE. NEC 250.94
  
  
 ROBERT LECKY, ELECTRIC PLANS EXAMINER, 561-805-6718

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2010-09-16 Cont ID  
Sent By jwitmer Date 2010-09-16 Time 15:12 Rev Time 0.00
Received By jwitmer Date 2010-09-16 Time 14:18 Sent To  
Notes
2010-09-16 15:23:22NO ELECTRIC PAGE IN PLANS
  
 JOHN DICKINSON CONTRACT PLAN REVEWER LICENSE NUMBER
 PX3182

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2011-02-09 Cont ID  
Sent By ddaniels Date 2011-02-09 Time 15:13 Rev Time 0.00
Received By ddaniels Date 2011-02-09 Time 15:13 Sent To  
Notes
2011-02-09 15:16:012/9/11 PLANS REVIEWED BY FIRE **APPROVED**
  
 1. SEPERATE PERMIT AND PLANS FOR HOOD SUPPRESSION
 SYSTEMS REQUIRED

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2011-01-06 Cont ID  
Sent By wjolin Date 2011-01-06 Time 14:03 Rev Time 0.00
Received By wjolin Date 2011-01-06 Time 13:49 Sent To  
Notes
2011-01-06 14:03:094310 BROADWAY AVENUE
 PERMIT #10090070
 REVIEW COMMENTS - FIRE
  
  
 THE SCOPE OF WORK INDICATED ON THE PERMIT APPLICATION
 IS TO INSTALL A SERVICE COUNTER. PROJECT SCOPE AND JOB
 VALUE APPEARS TO BE INACCURATE WHEN COMPARED TO THE
 SUBMITTED DRAWINGS.
  
 THE NEW FLOOR PLAN SHOWS A WALL RUNNING PARALLEL TO THE
 2-HOUR DEMISING WALL IN THE RETAIL AREA LABELED NO
 WORK. EXPLAIN.
  
 EXHAUST FAN DISCHARGE IS WITHIN INCHES OF THE ROOF
 PARAPET.
  
 SEPARATE PLANS AND PERMIT REQUIRED FOR HOOD SUPPRESSION
 SYSTEM.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-09-27 Cont ID  
Sent By mcarsill Date 2010-09-27 Time 10:42 Rev Time 0.00
Received By mcarsill Date 2010-09-27 Time 10:36 Sent To  
Notes
2010-09-27 10:42:094310 BROADWAY AVENUE
 PERMIT NUMBER 10090070
 "BUILD-NEW ADA SERVICE COUNTER"
  
  
 1. ON SHEET A-1 AN EXHAUST HOOD IS SHOWN BUT ON PAGE
 M-1 A NEW GREASE HOOD IS SHOWN. SEPARATE PLANS AND
 PERMITS REQUIRED FOR THE INSTALLATION OF A HOOD, DUCT,
 AND FIRE SUPPRESSION SYSTEM. THE HOOD EXTINGUISHING
 SYSTEM SHALL MEET THE REQUIREMENTS OF THE UL 300
 STANDARD.
  
 2. ON SHEET M-1 A REVISION FOR A RAISED PARAPET IS
 SHOWN. THIS WORK DOES NOT CORRESPOND TO INFORMATION
 LISTED ON THE PERMIT APPLICATION.
  
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
  
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2011-02-28 Cont ID  
Sent By lwagner Date 2011-02-28 Time 14:23 Rev Time 0.00
Received By lwagner Date 2011-02-28 Time 14:23 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2011-01-12 Cont ID  
Sent By lwagner Date 2011-01-12 Time 13:00 Rev Time 0.00
Received By lwagner Date 2011-01-12 Time 13:00 Sent To  
Notes
2011-01-12 13:05:46FBC FUEL GAS 2007
  
 1. PLEASE INCLUDE GAS PIPE SIZES ON GAS ISOMETRIC
 DRAWING.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-02-10 Cont ID  
Sent By rlecky Date 2011-02-10 Time 14:55 Rev Time 0.00
Received By rlecky Date 2011-02-09 Time 09:37 Sent To  
Notes
2011-02-09 09:47:52C1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-01-04 Cont ID  
Sent By jgomez Date 2011-01-04 Time 14:37 Rev Time 0.00
Received By jgomez Date 2011-01-04 Time 14:33 Sent To  
Notes
2011-01-04 14:38:12SENT TO B1.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-09-28 Cont ID  
Sent By lmartine Date 2010-09-28 Time 12:22 Rev Time 0.00
Received By lmartine Date 2010-09-09 Time 08:24 Sent To  
Notes
2010-09-09 08:24:55B7

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2011-03-07 Cont ID  
Sent By hmoser Date 2011-03-07 Time 13:41 Rev Time 0.00
Received By hmoser Date 2011-03-07 Time 13:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-01-11 Cont ID  
Sent By hmoser Date 2011-01-11 Time 13:48 Rev Time 0.00
Received By hmoser Date 2011-01-11 Time 13:48 Sent To  
Notes
2011-01-11 14:20:21PASS PROVISO
 REFER TO SECTION 304.10 GUARDS 2007 FBC (M) GUARDS
 SHALL BE PROVIDE
 WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS
 THAT REQUIRE
 SERVICE AND ROOF HATCH OPENINGS ARE LOCATED WITHIN 10'
 FT. OF A ROOF EDGE.
  
 REFER TO SECTION 566.3.12.3 TERMINATION LOCATION.2007
 FBC (M)
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-09-28 Cont ID  
Sent By hmoser Date 2010-09-28 Time 11:47 Rev Time 0.00
Received By hmoser Date 2010-09-28 Time 11:14 Sent To  
Notes
2010-09-28 12:00:06MECHANICAL PLANS DENIED
 1) SEPARATE PERMIT AND PLANS REQUIRED FOR GREASE HOOD .
 2) PLEASE REFER TO SECTION 506.3.12.3 TERMINATION
 LOCATION 2007 FBC. (M)
 3) PLEASE PROVIDE A DETAIL FOR THE EXHAUST AND SUPPLY
 FAN CURBS TIE DOWN TO THE ROOF ,FROM THE ENGINEER.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 3 Status P Date 2011-02-28 Cont ID  
Sent By lwagner Date 2011-02-28 Time 14:17 Rev Time 0.00
Received By lwagner Date 2011-02-28 Time 11:19 Sent To  
Notes
2011-02-28 13:27:43****PROVISO****
 HOT WATER IS REQUIRED AT HAND SINKS.
 FBC PLUMBING 2007 - 607.1.1
  
 *****PLEASE SUBMIT DBPR PLAN APPROVAL BEFORE PERMIT
 ISSUANCE*****
 HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/LICENSING/PLANR
 EVIEWINDEX.HTML

Review Stop P PLUMBING
Rev No 2 Status F Date 2011-01-12 Cont ID  
Sent By lwagner Date 2011-01-12 Time 12:59 Rev Time 0.00
Received By lwagner Date 2011-01-12 Time 09:34 Sent To  
Notes
2011-01-12 12:19:27FBC PLUMBING 2007 REVIEW #2
 DENIED:
  
 1. THE MOP SINK WILL BE REQUIRED TO BE CONNECTED TO THE
 GREASE TRAP. FBC PLUMBING 2007 1003.3.1 GREASE
 INTERCEPTORS AND AUTOMATIC GREASE REMOVAL DEVICES
 REQUIRED. A GREASE INTERCEPTOR OR AUTOMATIC GREASE
 REMOVAL DEVICE SHALL BE REQUIRED TO RECEIVE THE
 DRAINAGE FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN
 WASTE
  
 2. THE EQUIPMENT SCHEDULE ON SHEET A-1 CALLS FOR A 50
 GALLON GREASE TRAP WHICH WOULD BE CORRECT FOR A THREE
 COMPARTMENT SINK AND MOPSINK. THE GREASE TRAP ON P-1
 ZURN GT 2700-25 IS 25 GALLONS PER MINUTE.(PDI
 CALCULATES A TYPICAL THREE COMPARTMENT SINK AT 33.7 GPM
 FLOW).
  
 3. A WATER PIPE DRAWING IS REQUIRED FBC 106.3.5.1.3
  
 4. A DBPR HEALTH DEPT. PLAN OK WILL BE REQUIRED BEFORE
 PERMIT ISSUANCE. HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/H
 R/FORMS/PLANREVIEWFORMS.HTML
  
 5. THE PERMIT APPLICATION INDICATES THE SCOPE OF WORK
 FOR THIS PERMIT IS TO BUILD A NEW ADA SERVICE COUNTER.
 A NEW COMMERCIAL KITCHEN IS THE SCOPE OF WORK TO BE
 DESCRIBED UNDER THIS PERMIT, ALSO THE VALUE OF THIS
 PROJECT LOOKS TO BE TOO LOW (LISTED AS $1,000 ).
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-09-14 Cont ID  
Sent By lwagner Date 2010-09-14 Time 12:57 Rev Time 0.00
Received By lwagner Date 2010-09-13 Time 14:55 Sent To  
Notes
2010-09-13 15:12:41FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. SHEET C1 DRAWING INDEX REFERS TO P1 FOR PUMBING AND
 GAS - NO SHEET P1 WAS FOUND.
  
 2. SHEET C1 GENERAL NOTES - GAS SHALL COMPLY WITH FBC
 FUEL GAS 2007
  
 *****NOTE*****
 PLEASE INCLUDE THE SPECIFICATIONS FOR THE GREASE TRAP
 THAT IS TO BE INSTALLED, ALSO THE FLOW RATES FOR
 WHATEVER FIXTURES THAT ARE ATTACHED TO THE GREASE TRAP.
  
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2011-03-03 Cont ID  
Sent By astelly Date 2011-03-03 Time 16:56 Rev Time 0.00
Received By astelly Date 2011-03-03 Time 16:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2010-09-28 Cont ID  
Sent By lmartine Date 2010-09-23 Time 12:21 Rev Time 0.00
Received By lmartine Date 2010-09-20 Time 12:21 Sent To  
Notes
2010-09-28 12:22:03PER AMY STELLY