Plan Review Stops For Permit 10090070 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-03-01 |
Time |
08:50 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2011-03-01 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-01-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-01-05 |
Time |
14:12 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2011-01-05 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-09-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-09-09 |
Time |
10:25 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-09-09 |
Time |
10:25 |
Sent To |
|
|
Notes |
2010-09-09 10:32:31 | BUILDING PLAN REVIEW | | PERMIT: 10090070 | | ADD: 4310 BROADWAY | | CONT: J & M CONTRACTORS | | TEL: (561)718-7040 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) THE PERMIT APPLICATION INDICATES THE SCOPE OF WORK | | FOR THIS PERMIT IS TO BUILD A NEW ADA SERVICE COUNTER, | | WHERE AS THE PLANS INDICATE THE INCREASING OF THE | | HEIGHT OF THE PARAPET. THERE ARE OTHER APPLIED FOR | | PERMITS FOR NEW EXHAUST HOOD, AND A SEPARATE PERMIT | | WILL BE REQUIRED FOR THE WALK IN COOLER. IT APPEARS A | | NEW COMMERCIAL KITCHEN IS THE SCOPE OF WORK TO BE | | DESCRIBED UNDER THIS PERMIT. ADDITIONAL INFORMATION | | REQUIRED. | | | | 2) SHEET M-1 INDICATES A NEW PARAPET WALL FOUR FEET IN | | HEIGHT, IS THIS NEW WALL SURROUND THE BUILDING ON ALL | | FOUR SIDES? 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | 3) THE PLANS, SHEET M-1 INDICATES A NEW ROOF TOP | | EXHAUST FAN, PLEASE PROVIDE A CURB DETAIL HOW IT WILL | | BE ANCHORED TO THE EXISTING ROOFING ASSEMBLY. FBC-B | | 1609/ 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | 4) THE NEW ROOF TOP EXHAUST FAN WILL NEED PRODUCT | | APPROVALS AND ASSOCIATED PRESSURES IT WILL WITHSTAND. | | NOTE THIS SHOULD BE REVIEWED BY THE DESIGN PROFESSIONAL | | BEFORE BEING SUBMITTED TO THE BUILDING DEPARTMENT. | | FBC-B 1609. 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 5) A-1 INDICATES BOTH THE FRONT AND REAR DOOR HAVING A | | CHANGE IN GRADE GREATER THAN ?? INCH. PLEASE REVIEW | | 11-4.5.2 CHANGES IN LEVEL. CHANGES IN LEVEL UP TO 1/4 | | INCHES (6 MM) MAY BE VERTICAL AND WITHOUT EDGE | | TREATMENT [SEE FIGURE 7(C)]. CHANGES IN LEVEL BETWEEN | | 1/4 INCH AND 1/2 INCH (6 MM AND 13 MM) SHALL BE BEVELED | | WITH A SLOPE NO GREATER THAN 1:2 [SEE FIGURE 7(D)]. | | CHANGES IN LEVEL GREATER THAN 1/2 INCH (13 MM) SHALL BE | | ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH | | SECTION 11-4.7 OR 11-4.8. | | | | 6) THIS APPEARS TO BE A CHANGE OF OCCUPANCY REQUIRING | | PALM BEACH COUNTY IMPACT FEE ASSESSMENT. BEFORE A | | PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE | | PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF | | PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE | | PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE | | CALL (561)233-5025 FOR MORE INFORMATION. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2011-02-28 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-28 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-28 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2011-01-13 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-01-13 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-01-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
2011-01-12 14:39:05 | ELECTRIC PERMIT REQUIRED. | | REVISE SCOPE OF WORK AND VALUE TO REFLECT NEW ELECTRIC | | WORK | | UPDATE PERMIT FEE TO REFLECT VALUE OF WORK | | PROVIDE SIGN CIRCUIT. NEC 600.5 | | PROVIDE A BONDING BAR AT THE SERVICE. NEC 250.94 | | | | | | ROBERT LECKY, ELECTRIC PLANS EXAMINER, 561-805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2010-09-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-09-16 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-09-16 |
Time |
14:18 |
Sent To |
|
|
Notes |
2010-09-16 15:23:22 | NO ELECTRIC PAGE IN PLANS | | | | JOHN DICKINSON CONTRACT PLAN REVEWER LICENSE NUMBER | | PX3182 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2011-02-09 |
|
|
Cont ID |
|
Sent By |
ddaniels |
Date |
2011-02-09 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
ddaniels |
Date |
2011-02-09 |
Time |
15:13 |
Sent To |
|
|
Notes |
2011-02-09 15:16:01 | 2/9/11 PLANS REVIEWED BY FIRE **APPROVED** | | | | 1. SEPERATE PERMIT AND PLANS FOR HOOD SUPPRESSION | | SYSTEMS REQUIRED |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2011-01-06 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-01-06 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-01-06 |
Time |
13:49 |
Sent To |
|
|
Notes |
2011-01-06 14:03:09 | 4310 BROADWAY AVENUE | | PERMIT #10090070 | | REVIEW COMMENTS - FIRE | | | | | | THE SCOPE OF WORK INDICATED ON THE PERMIT APPLICATION | | IS TO INSTALL A SERVICE COUNTER. PROJECT SCOPE AND JOB | | VALUE APPEARS TO BE INACCURATE WHEN COMPARED TO THE | | SUBMITTED DRAWINGS. | | | | THE NEW FLOOR PLAN SHOWS A WALL RUNNING PARALLEL TO THE | | 2-HOUR DEMISING WALL IN THE RETAIL AREA LABELED NO | | WORK. EXPLAIN. | | | | EXHAUST FAN DISCHARGE IS WITHIN INCHES OF THE ROOF | | PARAPET. | | | | SEPARATE PLANS AND PERMIT REQUIRED FOR HOOD SUPPRESSION | | SYSTEM. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-09-27 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-09-27 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-09-27 |
Time |
10:36 |
Sent To |
|
|
Notes |
2010-09-27 10:42:09 | 4310 BROADWAY AVENUE | | PERMIT NUMBER 10090070 | | "BUILD-NEW ADA SERVICE COUNTER" | | | | | | 1. ON SHEET A-1 AN EXHAUST HOOD IS SHOWN BUT ON PAGE | | M-1 A NEW GREASE HOOD IS SHOWN. SEPARATE PLANS AND | | PERMITS REQUIRED FOR THE INSTALLATION OF A HOOD, DUCT, | | AND FIRE SUPPRESSION SYSTEM. THE HOOD EXTINGUISHING | | SYSTEM SHALL MEET THE REQUIREMENTS OF THE UL 300 | | STANDARD. | | | | 2. ON SHEET M-1 A REVISION FOR A RAISED PARAPET IS | | SHOWN. THIS WORK DOES NOT CORRESPOND TO INFORMATION | | LISTED ON THE PERMIT APPLICATION. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2011-02-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-02-28 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-02-28 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2011-01-12 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-01-12 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-01-12 |
Time |
13:00 |
Sent To |
|
|
Notes |
2011-01-12 13:05:46 | FBC FUEL GAS 2007 | | | | 1. PLEASE INCLUDE GAS PIPE SIZES ON GAS ISOMETRIC | | DRAWING. | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2011-02-10 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-10 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-09 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-01-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-01-04 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-01-04 |
Time |
14:33 |
Sent To |
|
|
Notes |
2011-01-04 14:38:12 | SENT TO B1. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-09-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-09-28 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-09 |
Time |
08:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2011-03-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-03-07 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-03-07 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2011-01-11 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-01-11 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-01-11 |
Time |
13:48 |
Sent To |
|
|
Notes |
2011-01-11 14:20:21 | PASS PROVISO | | REFER TO SECTION 304.10 GUARDS 2007 FBC (M) GUARDS | | SHALL BE PROVIDE | | WHERE APPLIANCES, EQUIPMENT, FANS OR OTHER COMPONENTS | | THAT REQUIRE | | SERVICE AND ROOF HATCH OPENINGS ARE LOCATED WITHIN 10' | | FT. OF A ROOF EDGE. | | | | REFER TO SECTION 566.3.12.3 TERMINATION LOCATION.2007 | | FBC (M) | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-09-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-09-28 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-09-28 |
Time |
11:14 |
Sent To |
|
|
Notes |
2010-09-28 12:00:06 | MECHANICAL PLANS DENIED | | 1) SEPARATE PERMIT AND PLANS REQUIRED FOR GREASE HOOD . | | 2) PLEASE REFER TO SECTION 506.3.12.3 TERMINATION | | LOCATION 2007 FBC. (M) | | 3) PLEASE PROVIDE A DETAIL FOR THE EXHAUST AND SUPPLY | | FAN CURBS TIE DOWN TO THE ROOF ,FROM THE ENGINEER. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2011-02-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-02-28 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-02-28 |
Time |
11:19 |
Sent To |
|
|
Notes |
2011-02-28 13:27:43 | ****PROVISO**** | | HOT WATER IS REQUIRED AT HAND SINKS. | | FBC PLUMBING 2007 - 607.1.1 | | | | *****PLEASE SUBMIT DBPR PLAN APPROVAL BEFORE PERMIT | | ISSUANCE***** | | HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/HR/LICENSING/PLANR | | EVIEWINDEX.HTML |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2011-01-12 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-01-12 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-01-12 |
Time |
09:34 |
Sent To |
|
|
Notes |
2011-01-12 12:19:27 | FBC PLUMBING 2007 REVIEW #2 | | DENIED: | | | | 1. THE MOP SINK WILL BE REQUIRED TO BE CONNECTED TO THE | | GREASE TRAP. FBC PLUMBING 2007 1003.3.1 GREASE | | INTERCEPTORS AND AUTOMATIC GREASE REMOVAL DEVICES | | REQUIRED. A GREASE INTERCEPTOR OR AUTOMATIC GREASE | | REMOVAL DEVICE SHALL BE REQUIRED TO RECEIVE THE | | DRAINAGE FROM FIXTURES AND EQUIPMENT WITH GREASE-LADEN | | WASTE | | | | 2. THE EQUIPMENT SCHEDULE ON SHEET A-1 CALLS FOR A 50 | | GALLON GREASE TRAP WHICH WOULD BE CORRECT FOR A THREE | | COMPARTMENT SINK AND MOPSINK. THE GREASE TRAP ON P-1 | | ZURN GT 2700-25 IS 25 GALLONS PER MINUTE.(PDI | | CALCULATES A TYPICAL THREE COMPARTMENT SINK AT 33.7 GPM | | FLOW). | | | | 3. A WATER PIPE DRAWING IS REQUIRED FBC 106.3.5.1.3 | | | | 4. A DBPR HEALTH DEPT. PLAN OK WILL BE REQUIRED BEFORE | | PERMIT ISSUANCE. HTTP://WWW.MYFLORIDALICENSE.COM/DBPR/H | | R/FORMS/PLANREVIEWFORMS.HTML | | | | 5. THE PERMIT APPLICATION INDICATES THE SCOPE OF WORK | | FOR THIS PERMIT IS TO BUILD A NEW ADA SERVICE COUNTER. | | A NEW COMMERCIAL KITCHEN IS THE SCOPE OF WORK TO BE | | DESCRIBED UNDER THIS PERMIT, ALSO THE VALUE OF THIS | | PROJECT LOOKS TO BE TOO LOW (LISTED AS $1,000 ). | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-09-14 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-09-14 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-09-13 |
Time |
14:55 |
Sent To |
|
|
Notes |
2010-09-13 15:12:41 | FBC PLUMBING 2007 REVIEW #1 | | DENIED: | | | | 1. SHEET C1 DRAWING INDEX REFERS TO P1 FOR PUMBING AND | | GAS - NO SHEET P1 WAS FOUND. | | | | 2. SHEET C1 GENERAL NOTES - GAS SHALL COMPLY WITH FBC | | FUEL GAS 2007 | | | | *****NOTE***** | | PLEASE INCLUDE THE SPECIFICATIONS FOR THE GREASE TRAP | | THAT IS TO BE INSTALLED, ALSO THE FLOW RATES FOR | | WHATEVER FIXTURES THAT ARE ATTACHED TO THE GREASE TRAP. | | | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2011-03-03 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-03-03 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-03-03 |
Time |
16:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2010-09-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-09-23 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-20 |
Time |
12:21 |
Sent To |
|
|
Notes |
2010-09-28 12:22:03 | PER AMY STELLY |
|
|