Plan Review Details - Permit 10090057
Plan Review Stops For Permit 10090057
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-10-08 Cont ID  
Sent By rmcdouga Date 2010-10-08 Time 13:25 Rev Time 0.00
Received By rmcdouga Date 2010-10-08 Time 13:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-09-29 Cont ID  
Sent By rmcdouga Date 2010-09-29 Time 14:48 Rev Time 0.00
Received By rmcdouga Date 2010-09-29 Time 14:48 Sent To  
Notes
2010-09-29 15:16:01DENIED BY BUILDING
  
 1) THE PLANS FROM THE ARCHITECT ARE REQUIRED TO HAVE
 HIS ORIGINAL SIGNATURE AND EMBOSSED SEAL PER FS 481.
  
 2) THE STRUCTURE IS LOCATED WITHIN 1500 FEET OF C-TYPE
 TERRAIN, THEREFORE PER FBC R301.2.1.4.3, THE EXPOSURE
 CATEGORY IS C. PLEASE REVISE THE PLANS AND DESIGN
 PRESSURES ACCORDINGLY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2010-09-15 Cont ID  
Sent By fmittner Date 2010-09-15 Time 09:44 Rev Time 0.00
Received By fmittner Date 2010-09-15 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-10-04 Cont ID  
Sent By lmartine Date 2010-10-04 Time 15:22 Rev Time 0.00
Received By lmartine Date 2010-10-04 Time 15:22 Sent To  
Notes
2010-10-04 15:23:29IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-09-29 Cont ID  
Sent By rmcdouga Date 2010-09-29 Time 15:16 Rev Time 0.00
Received By rmcdouga Date 2010-09-02 Time 10:57 Sent To  
Notes
2010-09-07 10:58:05SENT TO ZONING.

Review Stop Z ZONING
Rev No 2 Status P Date 2010-10-07 Cont ID  
Sent By eschneid Date 2010-10-07 Time 16:26 Rev Time 1.50
Received By eschneid Date 2010-10-06 Time 17:10 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2010-09-15 Cont ID  
Sent By eschneid Date 2010-09-15 Time 09:50 Rev Time 0.75
Received By eschneid Date 2010-09-08 Time 17:15 Sent To B
Notes
2010-09-15 10:01:44FAILED
  
 1) THE SITE PLAN PROVIDED WITH THE PERMIT DOES NOT
 MATCH THE 2009 AERIAL. PROVIDE A RECENT SURVEY, LESS
 THAN ONE YEAR OLD, WHICH SHOWS ALL IMPROVEMENTS AND THE
 DIMENSIONS TO THE PROPERTY LINES.
  
 2) THE SITE PLAN (OR A COPY OF SURVEY WITH PROPOSED
 PERGOLA DRAWN ON) SHALL INDICATE THE SETBACK FROM THE
 POSTS TO THE FRONT (NORTH) AND EAST SIDE PROPERTY
 LINES. THE REQUIRED FRONT SETBACK IS A MINIMUM OF 25
 FEET AND THE REQUIRED SIDE SETBACK IS A TOTAL OF AT
 LEAST 15 FEET FOR BOTH SIDES WITH ONE SIDE ABLE TO BE A
 MINIMUM OF 5 FEET. NOTE: THE SETBACK ON THE WEST SIDE
 OF THE PROPERTY WILL DETERMINE THE ALLOWED EAST
 SETBACK.
  
 3) THE 2009 AERIAL INDICATES THAT THERE MAY BE
 LANDSCAPE (TREES OR SHRUBS) REMOVED AS PART OF THE
 PERGOLA INSTALLATION. ANY TREES OR SHRUBS THAT ARE
 REMOVED AS PART OF THE INSTALLATION SHALL BE RELOCATED
 ON-SITE. PRIOR TO ANY TREE RELOCATION, A TREE
 ALTERATION PERMIT APPLICATION SHALL BE FILED WITH
 ROBERT KUSSNER IN THE PLANNING AND ZONING DEPARTMENT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.