Plan Review Details - Permit 10080752
Plan Review Stops For Permit 10080752
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-09-07 Cont ID  
Sent By jwitmer Date 2010-09-07 Time 08:48 Rev Time 0.00
Received By jwitmer Date 2010-09-07 Time 17:45 Sent To  
Notes
2010-09-07 18:00:49BUILDING PLAN REVIEW
 PERMIT: 10080752
 ADD: 5200 N FLAGLER DR SUITE# 1601
 CONT: A & A DEVELOPMENT
 TEL: (561)719-0895
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) TYPE I AND TYPE II CONSTRUCTION: 603.1 ALLOWABLE
 MATERIALS.(1).FIRE-RETARDANT-TREATED WOOD SHALL BE
 PERMITTED .
  
 2) 1207.2 AIR-BORNE SOUND. WALLS, PARTITIONS AND
 FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS FROM
 EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A
 SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45
 IF FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN
 ACCORDANCE WITH ASTM E 90. PENETRATIONS OR OPENINGS IN
 CONSTRUCTION ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES;
 RECESSED CABINETS; BATHTUBS; SOFFITS; OR HEATING,
 VENTILATING OR EXHAUST DUCTS SHALL BE SEALED, LINED,
 INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED
 RATINGS. THIS REQUIREMENT SHALL NOT APPLY TO DWELLING
 UNIT ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT
 FITTING TO THE FRAME AND SILL.
  
 3) 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING
 ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN A DWELLING
 UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE
 SHALL HAVE AN IMPACT INSULATION CLASS (IIC) RATING OF
 NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN
 ACCORDANCE WITH ASTM E 492.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-09-07 Cont ID  
Sent By dwise Date 2010-09-07 Time 15:58 Rev Time 0.00
Received By dwise Date 2010-09-07 Time 15:58 Sent To  
Notes
2010-09-07 15:59:16OK PER JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE
 NUMBER PX3182

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-09-13 Cont ID  
Sent By lwagner Date 2010-09-13 Time 08:49 Rev Time 0.00
Received By lwagner Date 2010-08-31 Time 10:36 Sent To  
Notes
2010-08-31 10:36:29B--2

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-09-13 Cont ID  
Sent By lwagner Date 2010-09-13 Time 08:46 Rev Time 0.00
Received By lwagner Date 2010-09-13 Time 08:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2010-09-02 Cont ID  
Sent By eschneid Date 2010-09-02 Time 16:51 Rev Time 0.25
Received By eschneid Date 2010-09-02 Time 16:51 Sent To  
Notes
2010-09-02 16:52:04WORK IN PAST YEAR LESS THAN 50% OF UNIT VALUE.