Plan Review Stops For Permit 10080639 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2011-06-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-06-06 |
Time |
07:44 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-06-06 |
Time |
07:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2011-04-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-04-27 |
Time |
09:05 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-04-27 |
Time |
09:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2011-02-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-02 |
Time |
14:45 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2011-02-02 |
Time |
14:00 |
Sent To |
|
|
Notes |
2011-02-02 15:14:43 | ADD: 2510 BROADWAY | | CONT: JHAMTREE | | TEL: (561)602-0009 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | 2ND REVIEW | | | | 1A) COMPLIED. | | | | 1B) SEMI- COMPLIED. SHEET SP-1 INDICATES AN OCCUPANT | | LOAD OF 52 OCCUPANTS, PLEASE REVIEW SECTION / TABLE | | 1015.1 WHICH WILL REQUIRE (2) POINTS OF EGRESS, AND | | THEY WILL TO MEET THE REQUIREMENT FOR 1/2 THE DIAGONAL | | DISTANCE APART FBC-B 1015.2.1. | | | | 1C) THE PROPOSED DOOR# (02) IS LOCATED2.5 FEET FROM | | THTE PROPERTY LINE SEE SP-1, PLEASE REVIEW FBC-B TABLE | | 704.7 FOR ALLOWABLE OPENINGS, UNPROTECTED OR PROTECTED, | | 0-5 FEET OPENINGS ARE NOT ALLOWED. | | | | 2-6) COMPLIED. | | | | 7) EVEN IF THE DESIGNEER OF RECORD PULL THE DOOR# 02 | | BACK BEYOND THE 0-3' ALLOWING FOR PROTECTED OPENINGS | | THE OTHER ISSUE WILL BE WITH THE EXIT DISCHARGE MEETING | | THESE REQUIREMENTS: | | | | 2007/ 2009 FBC-B 1024.3 EXIT DISCHARGE LOCATION. | | EXTERIOR BALCONIES, STAIRWAYS AND RAMPS SHALL BE | | LOCATED AT LEAST 10 FEET (3048 MM) FROM ADJACENT LOT | | LINES AND FROM OTHER BUILDINGS ON THE SAME LOT UNLESS | | THE ADJACENT BUILDING EXTERIOR WALLS AND OPENINGS ARE | | PROTECTED IN ACCORDANCE WITH SECTION 704 BASED ON FIRE | | SEPARATION DISTANCE. | | | | 2007/ 2009 FBC-B 1024.4 EXIT DISCHARGE COMPONENTS. EXIT | | DISCHARGE COMPONENTS SHALL BE SUFFICIENTLY OPEN TO THE | | EXTERIOR SO AS TO MINIMIZE THE ACCUMULATION OF SMOKE | | AND TOXIC GASES. | | | | 2007/ 2009 FBC-B 1024.5 EGRESS COURTS. EGRESS COURTS | | SERVING AS A PORTION OF THE EXIT DISCHARGE IN THE MEANS | | OF EGRESS SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF | | SECTION 1024. | | | | 2007/ 2009 FBC-B 1024.5.1 WIDTH. THE WIDTH OF EGRESS | | COURTS SHALL BE DETERMINED AS SPECIFIED IN SECTION | | 1005.1, BUT SUCH WIDTH SHALL NOT BE LESS THAN 44 | | INCHES. | | | | THE CONTRACTOR SUBMITTED A PRODUCT APPROVAL FOR DOOR # | | 2 QUALITY ENGINEERED PRODUCT CO. INC. FOR WIND AND | | LARGE MISSILE IMPACT BUT NO TESTING REPORT FOR THE FIRE | | RATING OF DOOR, 2007/ 2009 FBC-B TABLE 715.4. | | | | 8) THE COVER SHEET INDICATES THE PREVIOUS TENANT TO BE | | A AUTO REPAIR GARAGE MAKING THIS A S-1 OCCUPANCY. A | | CHANGE IN OCCUPANCY REQUIRES IMPACT FEE REVIEW. BEFORE | | A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST | | BE PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF | | PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE | | PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE | | CALL (561)233-5025 FOR MORE INFORMATION. | | | | JAMES A. WITMER C.B.O. | | COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: (561)805-6715 | | FAX:(561)805-6731 | | E-MAIL: [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-09-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-09-14 |
Time |
13:14 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-09-14 |
Time |
08:20 |
Sent To |
|
|
Notes |
2010-09-14 13:58:04 | BUILDING PLAN REVIEW | | PERMIT: 10080639 | | ADD: 2510 BROADWAY | | CONT: T B D | | TEL: (561)853-7013 EDMUND THOMPSON | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1A) PLEASE INDICATE ON SHEET A-1THE COMMON PATH OF | | TRAVEL WITH ALL KIOSK AND STANDS THAT WILL BE LOCATED | | IN THE MERCANTILE OCCUPANCY, THE COMON PATH OF TRAVEL | | CAN NOT EXCEED 75'-0 FOR A SINGLE EXIT MERCANTILE | | OCCUPANCY. FBC-B 1014.3, | | | | 1B) SHEET SP-1 INDICATES AN OCCUPANT LOAD OF 52 | | OCCUPANTS, PLEASE REVIEW SECTION / TABLE 1015.1 WHICH | | WILL REQUIRE (2) POINTS OF EGRESS, AND THEY WILL TO | | MEET THE REQUIREMENT FOR 1/2 THE DIAGONAL DISTANCE | | APART FBC-B 1015.2.1. | | | | 1C) THE PROPOSED DOOR# (02) IS LOCATED2.5 FEET FROM | | THTE PROPERTY LINE SEE SP-1, PLEASE REVIEW FBC-B TABLE | | 704.7 FOR ALLOWABLE OPENINGS, UNPROTECTED 0-5 FEET | | OPENINGS ARE NOT ALLOWED. | | | | 2) BOTH LS-1 & A-1 THE PLANS INDICATE A NEW HANDICAPPED | | RAMP BUT NO BOTTOM LANDING IS INDICATED PLEASE PROVIDE | | COMPLIANCE WITH : 11-4.8.4.(2) LANDINGS. ALL LANDINGS | | ON RAMPS SHALL NOT BE LESS THAN 60" CLEAR, & THE BOTTOM | | OF EACH RAMP SHALL HAVE NOT LESS THAN 72" OF STRAIGHT & | | LEVEL CLEARENCE. | | | | 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 3A) STOREFRONT WINDOWS | | 3B) STOREFRONT DOOR | | 3C) SHUTTERS IF GLAZED OPENINGS ARE NOT LARGE MISSILE | | IMPACT TESTED | | | | 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 5 BOTH SHEETS A-3 & A-5 INDICATE CUT WALL SECTIONS AND | | DETAILS FOR WALL RE-INFORCEMENT, THERE ARE NO DETAILS | | PROVIDING HOW COMPLIANCE WITH MAIN WIND FORCE RESISTING | | SYSTEM. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | LOADS. | | FBC-B 2107.2 ACI 530. THE PLANS ARE MISSING THE LATERAL | | REINFORCEMENT OF EVERY OTHER COARSE. | | | | 6) PLEASE REVIEW SHEET A-4: | | 6A) DETAIL "C" THE GRAB BAR TO BE A MAXIMUM OF 12" FROM | | THE CORNER 11-4.16.4 TOILET ROOMS. | | | | 6B) DETAIL "B" THE WATERCLOSET IS TO BE LOCATED 18" | | CENTER LINE TO ADJACENT WALL. 11-4.16.2 FIGURE 11-28. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2011-05-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-05-09 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-05-09 |
Time |
14:56 |
Sent To |
|
|
Notes |
2011-05-09 14:56:49 | NO ELECTRIC WORK PROPOSED OR SHOWN TO BE DONE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2011-02-07 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-07 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-07 |
Time |
09:43 |
Sent To |
|
|
Notes |
2011-02-07 09:52:40 | AN ELECTRICAL PERMIT AND PLAN SHOWING SCOPE OF | | ELECTRICAL WORK IS REQUIRED. | | A GFCI PROTECTED RECEPTACLE IS REQUIRED TO SERVICE ROOF | | TOP AC. | | VERIFY EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR ALL | | NEW AND EXISTING LOADS. | | | | | | ROBERT LECKY, ELECTRIC PLAN REVIEW, 561-805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-09-13 |
|
|
Cont ID |
|
Sent By |
dwise |
Date |
2010-09-13 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
dwise |
Date |
2010-09-13 |
Time |
17:34 |
Sent To |
|
|
Notes |
2010-09-13 17:41:27 | *****************ELECTRICAL PLAN REVEW FAIL | | *********************** | | PL;AN HAS NO ELECTRICAL INFOMATION ON IT | | WILL NEED INFO ON NEW BATH ELECT | | INFO ON NEW A/C UNIT ON ROOF | | ALSO ELECT SERVICE RISER DIAGRAM AND LOAD CALCUATIONS | | JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE NUMBER | | PX3182 | | CELL NUMBER 561 718 3230 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2011-06-03 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-06-03 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-06-03 |
Time |
15:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2011-01-27 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-01-27 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-01-27 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-09-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-09-17 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-09-17 |
Time |
11:18 |
Sent To |
|
|
Notes |
2010-09-17 11:23:28 | 2510 BROADWAY | | PERMIT NUMBER 10080639 | | | | 1. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS. | | | | 2. BUILDING ADDRESS NOT SHOWN ON ELEVATION DRAWINGS. | | THE BUILDING ADDRESS SHALL BE A MINIMUM OF AT LEAST 6" | | HIGH AND AT LEAST 1" WIDE AND IT SHALL CONTRAST WITH | | THE BACKGROUND THAT IT IS AFFIXED TO. | | | | 3. SINCE NO COOKING EQUIPMENT IS SHOWN, NO COOKING IS | | ALLOWED. ANY COOKING THAT PRODUCES SMOKE OR GREASE | | LADEN VAPORS SHALL BE PROTECTED BY A HOOD,DUCT, AND | | FIRE SUPPRESSION SYSTEM. SEPARATE PLANS AND PERMITS | | REQUIRED. | | | | 4. INTERIOR FINISH CLASSIFICATIONS FOR WALLS AND | | CEILINGS SHALL BE CLASS A OR B AND NOT C AS LISTED ON | | THE PLANS. | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2011-06-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-06-06 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-05-27 |
Time |
16:20 |
Sent To |
|
|
Notes |
2011-06-02 15:43:47 | 6/2 ROUTED TO JW DESK FOR PROCESSING/ISSUANCE | | | | | 2011-05-27 16:20:31 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2011-05-10 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-05-09 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-04-25 |
Time |
17:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2011-02-17 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-01-25 |
Time |
07:47 |
Sent To |
|
|
Notes |
2011-01-25 08:01:29 | INCOMING SENT TO C-14. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-09-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-09-17 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-08-24 |
Time |
11:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
N |
Date |
2010-08-26 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-08-26 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-08-26 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-03-01 |
Time |
06:59 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-03-01 |
Time |
06:59 |
Sent To |
|
|
Notes |
2011-03-01 07:02:28 | AIRCONDITIONING CONTRACTOR IS TO SUBMIT PLANS AT TIME | | OF APPLICATION. | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-09-14 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-09-14 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-09-14 |
Time |
18:11 |
Sent To |
|
|
Notes |
2010-09-14 18:21:47 | REVIEW #: 1ST | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. SCOPE OF WORK ON PERMIT APPLICATION INDICATES "A/C | | UNIT ON ROOF." NO INFORMATION WAS PROVIDED REGARDING | | ANY NEW A/C EQUIPMENT ON PLANS. PROVIDE EQUIPMENT | | SCHEDULE WITH INSTALLATION DETAILS PER FBC-B 106.1.1 | | AND 106.3.5. | | | | 2. PLANS APPEAR TO SHOW UNCONDITIONED SPACE BEING | | CONVERTED TO CONDITIONED SPACE. THIS CONSTITUTES AN | | ADDITION PER DEFINITIONS IN FBC-B 13-202. SHOW | | COMPLIANCE WITH ENERGY CODE REQUIREMENTS FOR AN | | ADDITION PER FBC-B 13-101.1.2, INCLUDING SUBMISSION OF | | AN ENERGY CODE COMPLIANCE FORM AND APPENDED COOLING | | LOAD CALCULATIONS. | | | | 3. PROVIDE VENTILATION CALCULATIONS FOR THE NEW | | OCCUPANCY OF THE CONVERTED SPACE IN ACCORDANCE WITH | | FBC-EB 909.1. | | | | 4. PROVIDE DUCT LAYOUT SHOWING THE AIR DISTRIBUTION | | SYSTEM FOR THE NEWLY CONVERTED SPACE PER FBC-M 603.1. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2011-05-04 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-05-04 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-05-03 |
Time |
11:02 |
Sent To |
|
|
Notes |
2011-05-04 10:38:48 | PLUMBING IS NOT INCLUDED IN THIS REVIEW. SEPARATE | | PLUMBING APPLICATION, PLAN, PERMIT, AND VALUATION | | REQUIRED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2011-02-17 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-02-17 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-02-17 |
Time |
12:57 |
Sent To |
|
|
Notes |
2011-02-17 13:00:01 | NO PLUMBING IS SHOWN ON THIS PLAN TO REVIEW (SEE | | COMMENTS IN FORMER PLUMBING REVIEW) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-09-17 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-09-17 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-09-16 |
Time |
15:01 |
Sent To |
|
|
Notes |
2010-09-17 11:44:16 | PLUMBING PLAN REVIEW | | DENIED: | | | | NO PLUMBING PLANS WERE SUBMITTED. | | | | *****NOTE****** | | IF FOOD IS BEING PREPARED IN THIS SPACE A GREASE TRAP | | OR INTERCEPTOR, MOP SINK, 3 COMPARTMENT SINK MAY BE | | REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2011-06-02 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-06-02 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-06-02 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2011-05-04 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-05-04 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-05-04 |
Time |
15:03 |
Sent To |
|
|
Notes |
2011-05-04 15:08:24 | AMY STELLY | | PLANNING AND ZONING | | 822-1442 | | | | THE LIFE SAFETY PLAN REFLECTS AN EXPANSION OF THE | | CONVENIENCE STORE. THE CONVENIENCE STORE CANNOT BE | | EXPAND ACCORDING TO THE PROPERTY'S CLASS B SPECIAL USE | | PERMIT ISSUED BY THE ZONING BOARD OF APPEALS. A NEW | | PLAN REFLECTING A PERMITTED USE WILL HAVE TO BE | | SUBMITTED FOR THE ZONING REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2011-01-27 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-01-27 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-01-27 |
Time |
14:24 |
Sent To |
|
|
Notes |
2011-01-27 14:35:02 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | 1. PLEASE PROVIDE DIMENSIONS FOR ALL GLAZED AREAS. | | PURSUANT TO 94- 213, STOREFRONTS SHALL PROVIDE CLEAR | | GLAZED AREAS AS FOLLOWS: | | | | A.FOR NEW CONSTRUCTION, EACH STOREFRONT SHALL HAVE | | CLEAR GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF | | ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND | | AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL FRONTAGES. | | | | B.RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE) | | TO EXISTING BUILDINGS SHALL NOT REDUCE THE ORIGINAL | | PERCENTAGE OF CLEAR GLAZED AREAS, IF IT IS MORE THAN 50 | | PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM | | THE GROUND. | | | | C.RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE) | | TO EXISTING BUILDINGS THAT HAVE CLEAR GLAZED AREAS LESS | | THAN 50 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT | | FEET FROM THE GROUND, MUST PROVIDE AT LEAST 50 PERCENT | | CLEAR GLAZED OF ITS FACADE, BETWEEN TWO AND EIGHT FEET | | FROM THE GROUND. | | | | D.ADDITIONS ON THE FRONTAGE LINE SHALL HAVE CLEAR | | GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF ITS | | FRONT FACADE, BETWEEN TWO AND EIGHT FEET FROM THE | | GROUND AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL | | FRONTAGES. | | | | 2. THE LOCATION AND SCREENING FOR THE DUMPSTER MUST | | ALSO BE SHOWN ON THE SITE PLAN. | | | | 3. PLEASE INCLUDE A SURVEY WITH THE RESUBMISSION. | | | | 4. REPEAT COMMENT: | | PLEASE SHOW THE LOCATION AND SCREENING FOR ALL | | MECHANICAL EQUIPMENT. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-08-30 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-30 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-08-30 |
Time |
15:14 |
Sent To |
|
|
Notes |
2010-08-30 15:15:07 | SHOW LOCATION AND SCREENING OF A/C UNIT ON THE ROOF IN | | PLAN AND ELEVATION. | | | | | | | | AMY | | 822-1442 |
|
|