Plan Review Details - Permit 10080639
Plan Review Stops For Permit 10080639
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-06-06 Cont ID  
Sent By jwitmer Date 2011-06-06 Time 07:44 Rev Time 0.77
Received By jwitmer Date 2011-06-06 Time 07:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-04-27 Cont ID  
Sent By jwitmer Date 2011-04-27 Time 09:05 Rev Time 0.77
Received By jwitmer Date 2011-04-27 Time 09:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-02-02 Cont ID  
Sent By jwitmer Date 2011-02-02 Time 14:45 Rev Time 0.75
Received By jwitmer Date 2011-02-02 Time 14:00 Sent To  
Notes
2011-02-02 15:14:43ADD: 2510 BROADWAY
 CONT: JHAMTREE
 TEL: (561)602-0009
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 2ND REVIEW
  
 1A) COMPLIED.
  
 1B) SEMI- COMPLIED. SHEET SP-1 INDICATES AN OCCUPANT
 LOAD OF 52 OCCUPANTS, PLEASE REVIEW SECTION / TABLE
 1015.1 WHICH WILL REQUIRE (2) POINTS OF EGRESS, AND
 THEY WILL TO MEET THE REQUIREMENT FOR 1/2 THE DIAGONAL
 DISTANCE APART FBC-B 1015.2.1.
  
 1C) THE PROPOSED DOOR# (02) IS LOCATED2.5 FEET FROM
 THTE PROPERTY LINE SEE SP-1, PLEASE REVIEW FBC-B TABLE
 704.7 FOR ALLOWABLE OPENINGS, UNPROTECTED OR PROTECTED,
 0-5 FEET OPENINGS ARE NOT ALLOWED.
  
 2-6) COMPLIED.
  
 7) EVEN IF THE DESIGNEER OF RECORD PULL THE DOOR# 02
 BACK BEYOND THE 0-3' ALLOWING FOR PROTECTED OPENINGS
 THE OTHER ISSUE WILL BE WITH THE EXIT DISCHARGE MEETING
 THESE REQUIREMENTS:
  
 2007/ 2009 FBC-B 1024.3 EXIT DISCHARGE LOCATION.
 EXTERIOR BALCONIES, STAIRWAYS AND RAMPS SHALL BE
 LOCATED AT LEAST 10 FEET (3048 MM) FROM ADJACENT LOT
 LINES AND FROM OTHER BUILDINGS ON THE SAME LOT UNLESS
 THE ADJACENT BUILDING EXTERIOR WALLS AND OPENINGS ARE
 PROTECTED IN ACCORDANCE WITH SECTION 704 BASED ON FIRE
 SEPARATION DISTANCE.
  
 2007/ 2009 FBC-B 1024.4 EXIT DISCHARGE COMPONENTS. EXIT
 DISCHARGE COMPONENTS SHALL BE SUFFICIENTLY OPEN TO THE
 EXTERIOR SO AS TO MINIMIZE THE ACCUMULATION OF SMOKE
 AND TOXIC GASES.
  
 2007/ 2009 FBC-B 1024.5 EGRESS COURTS. EGRESS COURTS
 SERVING AS A PORTION OF THE EXIT DISCHARGE IN THE MEANS
 OF EGRESS SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTION 1024.
  
 2007/ 2009 FBC-B 1024.5.1 WIDTH. THE WIDTH OF EGRESS
 COURTS SHALL BE DETERMINED AS SPECIFIED IN SECTION
 1005.1, BUT SUCH WIDTH SHALL NOT BE LESS THAN 44
 INCHES.
  
 THE CONTRACTOR SUBMITTED A PRODUCT APPROVAL FOR DOOR #
 2 QUALITY ENGINEERED PRODUCT CO. INC. FOR WIND AND
 LARGE MISSILE IMPACT BUT NO TESTING REPORT FOR THE FIRE
 RATING OF DOOR, 2007/ 2009 FBC-B TABLE 715.4.
  
 8) THE COVER SHEET INDICATES THE PREVIOUS TENANT TO BE
 A AUTO REPAIR GARAGE MAKING THIS A S-1 OCCUPANCY. A
 CHANGE IN OCCUPANCY REQUIRES IMPACT FEE REVIEW. BEFORE
 A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST
 BE PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF
 PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE
 PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE
 CALL (561)233-5025 FOR MORE INFORMATION.
  
 JAMES A. WITMER C.B.O.
 COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-09-14 Cont ID  
Sent By jwitmer Date 2010-09-14 Time 13:14 Rev Time 0.77
Received By jwitmer Date 2010-09-14 Time 08:20 Sent To  
Notes
2010-09-14 13:58:04BUILDING PLAN REVIEW
 PERMIT: 10080639
 ADD: 2510 BROADWAY
 CONT: T B D
 TEL: (561)853-7013 EDMUND THOMPSON
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1A) PLEASE INDICATE ON SHEET A-1THE COMMON PATH OF
 TRAVEL WITH ALL KIOSK AND STANDS THAT WILL BE LOCATED
 IN THE MERCANTILE OCCUPANCY, THE COMON PATH OF TRAVEL
 CAN NOT EXCEED 75'-0 FOR A SINGLE EXIT MERCANTILE
 OCCUPANCY. FBC-B 1014.3,
  
 1B) SHEET SP-1 INDICATES AN OCCUPANT LOAD OF 52
 OCCUPANTS, PLEASE REVIEW SECTION / TABLE 1015.1 WHICH
 WILL REQUIRE (2) POINTS OF EGRESS, AND THEY WILL TO
 MEET THE REQUIREMENT FOR 1/2 THE DIAGONAL DISTANCE
 APART FBC-B 1015.2.1.
  
 1C) THE PROPOSED DOOR# (02) IS LOCATED2.5 FEET FROM
 THTE PROPERTY LINE SEE SP-1, PLEASE REVIEW FBC-B TABLE
 704.7 FOR ALLOWABLE OPENINGS, UNPROTECTED 0-5 FEET
 OPENINGS ARE NOT ALLOWED.
  
 2) BOTH LS-1 & A-1 THE PLANS INDICATE A NEW HANDICAPPED
 RAMP BUT NO BOTTOM LANDING IS INDICATED PLEASE PROVIDE
 COMPLIANCE WITH : 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60" CLEAR, & THE BOTTOM
 OF EACH RAMP SHALL HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
  
 3) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 3A) STOREFRONT WINDOWS
 3B) STOREFRONT DOOR
 3C) SHUTTERS IF GLAZED OPENINGS ARE NOT LARGE MISSILE
 IMPACT TESTED
  
 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 5 BOTH SHEETS A-3 & A-5 INDICATE CUT WALL SECTIONS AND
 DETAILS FOR WALL RE-INFORCEMENT, THERE ARE NO DETAILS
 PROVIDING HOW COMPLIANCE WITH MAIN WIND FORCE RESISTING
 SYSTEM. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
 FBC-B 2107.2 ACI 530. THE PLANS ARE MISSING THE LATERAL
 REINFORCEMENT OF EVERY OTHER COARSE.
  
 6) PLEASE REVIEW SHEET A-4:
 6A) DETAIL "C" THE GRAB BAR TO BE A MAXIMUM OF 12" FROM
 THE CORNER 11-4.16.4 TOILET ROOMS.
  
 6B) DETAIL "B" THE WATERCLOSET IS TO BE LOCATED 18"
 CENTER LINE TO ADJACENT WALL. 11-4.16.2 FIGURE 11-28.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2011-05-09 Cont ID  
Sent By rlecky Date 2011-05-09 Time 14:56 Rev Time 0.00
Received By rlecky Date 2011-05-09 Time 14:56 Sent To  
Notes
2011-05-09 14:56:49NO ELECTRIC WORK PROPOSED OR SHOWN TO BE DONE.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2011-02-07 Cont ID  
Sent By rlecky Date 2011-02-07 Time 09:53 Rev Time 0.00
Received By rlecky Date 2011-02-07 Time 09:43 Sent To  
Notes
2011-02-07 09:52:40AN ELECTRICAL PERMIT AND PLAN SHOWING SCOPE OF
 ELECTRICAL WORK IS REQUIRED.
 A GFCI PROTECTED RECEPTACLE IS REQUIRED TO SERVICE ROOF
 TOP AC.
 VERIFY EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR ALL
 NEW AND EXISTING LOADS.
  
  
 ROBERT LECKY, ELECTRIC PLAN REVIEW, 561-805-6718
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-09-13 Cont ID  
Sent By dwise Date 2010-09-13 Time 17:34 Rev Time 0.00
Received By dwise Date 2010-09-13 Time 17:34 Sent To  
Notes
2010-09-13 17:41:27*****************ELECTRICAL PLAN REVEW FAIL
 ***********************
 PL;AN HAS NO ELECTRICAL INFOMATION ON IT
 WILL NEED INFO ON NEW BATH ELECT
 INFO ON NEW A/C UNIT ON ROOF
 ALSO ELECT SERVICE RISER DIAGRAM AND LOAD CALCUATIONS
 JOHN DICKINSON CONTRACT PLAN REVIEWER LICENSE NUMBER
 PX3182
 CELL NUMBER 561 718 3230

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2011-06-03 Cont ID  
Sent By wjolin Date 2011-06-03 Time 15:45 Rev Time 0.00
Received By wjolin Date 2011-06-03 Time 15:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2011-01-27 Cont ID  
Sent By wjolin Date 2011-01-27 Time 15:43 Rev Time 0.00
Received By wjolin Date 2011-01-27 Time 15:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-09-17 Cont ID  
Sent By mcarsill Date 2010-09-17 Time 11:23 Rev Time 0.00
Received By mcarsill Date 2010-09-17 Time 11:18 Sent To  
Notes
2010-09-17 11:23:282510 BROADWAY
 PERMIT NUMBER 10080639
  
 1. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS.
  
 2. BUILDING ADDRESS NOT SHOWN ON ELEVATION DRAWINGS.
 THE BUILDING ADDRESS SHALL BE A MINIMUM OF AT LEAST 6"
 HIGH AND AT LEAST 1" WIDE AND IT SHALL CONTRAST WITH
 THE BACKGROUND THAT IT IS AFFIXED TO.
  
 3. SINCE NO COOKING EQUIPMENT IS SHOWN, NO COOKING IS
 ALLOWED. ANY COOKING THAT PRODUCES SMOKE OR GREASE
 LADEN VAPORS SHALL BE PROTECTED BY A HOOD,DUCT, AND
 FIRE SUPPRESSION SYSTEM. SEPARATE PLANS AND PERMITS
 REQUIRED.
  
 4. INTERIOR FINISH CLASSIFICATIONS FOR WALLS AND
 CEILINGS SHALL BE CLASS A OR B AND NOT C AS LISTED ON
 THE PLANS.
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-06-06 Cont ID  
Sent By jwitmer Date 2011-06-06 Time 07:44 Rev Time 0.00
Received By jwitmer Date 2011-05-27 Time 16:20 Sent To  
Notes
2011-06-02 15:43:476/2 ROUTED TO JW DESK FOR PROCESSING/ISSUANCE
  
  
2011-05-27 16:20:31IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-05-10 Cont ID  
Sent By lmartine Date 2011-05-09 Time 14:41 Rev Time 0.00
Received By lmartine Date 2011-04-25 Time 17:06 Sent To  
Notes
2011-04-25 17:10:29C9

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2011-02-17 Time   Rev Time 0.00
Received By jwitmer Date 2011-01-25 Time 07:47 Sent To  
Notes
2011-01-25 08:01:29INCOMING SENT TO C-14. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-09-27 Cont ID  
Sent By shill Date 2010-09-17 Time 10:07 Rev Time 0.00
Received By shill Date 2010-08-24 Time 11:57 Sent To  
Notes
2010-08-24 11:57:38C24

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2010-08-26 Cont ID  
Sent By rkussner Date 2010-08-26 Time 10:35 Rev Time 0.00
Received By rkussner Date 2010-08-26 Time 10:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2011-03-01 Cont ID  
Sent By hmoser Date 2011-03-01 Time 06:59 Rev Time 0.00
Received By hmoser Date 2011-03-01 Time 06:59 Sent To  
Notes
2011-03-01 07:02:28AIRCONDITIONING CONTRACTOR IS TO SUBMIT PLANS AT TIME
 OF APPLICATION.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-09-14 Cont ID  
Sent By rregueir Date 2010-09-14 Time 18:21 Rev Time 0.00
Received By rregueir Date 2010-09-14 Time 18:11 Sent To  
Notes
2010-09-14 18:21:47REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. SCOPE OF WORK ON PERMIT APPLICATION INDICATES "A/C
 UNIT ON ROOF." NO INFORMATION WAS PROVIDED REGARDING
 ANY NEW A/C EQUIPMENT ON PLANS. PROVIDE EQUIPMENT
 SCHEDULE WITH INSTALLATION DETAILS PER FBC-B 106.1.1
 AND 106.3.5.
  
 2. PLANS APPEAR TO SHOW UNCONDITIONED SPACE BEING
 CONVERTED TO CONDITIONED SPACE. THIS CONSTITUTES AN
 ADDITION PER DEFINITIONS IN FBC-B 13-202. SHOW
 COMPLIANCE WITH ENERGY CODE REQUIREMENTS FOR AN
 ADDITION PER FBC-B 13-101.1.2, INCLUDING SUBMISSION OF
 AN ENERGY CODE COMPLIANCE FORM AND APPENDED COOLING
 LOAD CALCULATIONS.
  
 3. PROVIDE VENTILATION CALCULATIONS FOR THE NEW
 OCCUPANCY OF THE CONVERTED SPACE IN ACCORDANCE WITH
 FBC-EB 909.1.
  
 4. PROVIDE DUCT LAYOUT SHOWING THE AIR DISTRIBUTION
 SYSTEM FOR THE NEWLY CONVERTED SPACE PER FBC-M 603.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status N Date 2011-05-04 Cont ID  
Sent By lwagner Date 2011-05-04 Time 10:35 Rev Time 0.00
Received By lwagner Date 2011-05-03 Time 11:02 Sent To  
Notes
2011-05-04 10:38:48PLUMBING IS NOT INCLUDED IN THIS REVIEW. SEPARATE
 PLUMBING APPLICATION, PLAN, PERMIT, AND VALUATION
 REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status F Date 2011-02-17 Cont ID  
Sent By lwagner Date 2011-02-17 Time 12:58 Rev Time 0.00
Received By lwagner Date 2011-02-17 Time 12:57 Sent To  
Notes
2011-02-17 13:00:01NO PLUMBING IS SHOWN ON THIS PLAN TO REVIEW (SEE
 COMMENTS IN FORMER PLUMBING REVIEW)

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-09-17 Cont ID  
Sent By lwagner Date 2010-09-17 Time 11:44 Rev Time 0.00
Received By lwagner Date 2010-09-16 Time 15:01 Sent To  
Notes
2010-09-17 11:44:16PLUMBING PLAN REVIEW
 DENIED:
  
 NO PLUMBING PLANS WERE SUBMITTED.
  
 *****NOTE******
 IF FOOD IS BEING PREPARED IN THIS SPACE A GREASE TRAP
 OR INTERCEPTOR, MOP SINK, 3 COMPARTMENT SINK MAY BE
 REQUIRED.

Review Stop Z ZONING
Rev No 4 Status P Date 2011-06-02 Cont ID  
Sent By astelly Date 2011-06-02 Time 14:49 Rev Time 0.00
Received By astelly Date 2011-06-02 Time 14:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2011-05-04 Cont ID  
Sent By astelly Date 2011-05-04 Time 15:03 Rev Time 0.00
Received By astelly Date 2011-05-04 Time 15:03 Sent To  
Notes
2011-05-04 15:08:24AMY STELLY
 PLANNING AND ZONING
 822-1442
  
 THE LIFE SAFETY PLAN REFLECTS AN EXPANSION OF THE
 CONVENIENCE STORE. THE CONVENIENCE STORE CANNOT BE
 EXPAND ACCORDING TO THE PROPERTY'S CLASS B SPECIAL USE
 PERMIT ISSUED BY THE ZONING BOARD OF APPEALS. A NEW
 PLAN REFLECTING A PERMITTED USE WILL HAVE TO BE
 SUBMITTED FOR THE ZONING REVIEW.

Review Stop Z ZONING
Rev No 2 Status F Date 2011-01-27 Cont ID  
Sent By astelly Date 2011-01-27 Time 14:24 Rev Time 0.00
Received By astelly Date 2011-01-27 Time 14:24 Sent To  
Notes
2011-01-27 14:35:02AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 1. PLEASE PROVIDE DIMENSIONS FOR ALL GLAZED AREAS.
 PURSUANT TO 94- 213, STOREFRONTS SHALL PROVIDE CLEAR
 GLAZED AREAS AS FOLLOWS:
  
 A.FOR NEW CONSTRUCTION, EACH STOREFRONT SHALL HAVE
 CLEAR GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF
 ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND
 AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL FRONTAGES.
  
 B.RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS SHALL NOT REDUCE THE ORIGINAL
 PERCENTAGE OF CLEAR GLAZED AREAS, IF IT IS MORE THAN 50
 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM
 THE GROUND.
  
 C.RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS THAT HAVE CLEAR GLAZED AREAS LESS
 THAN 50 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT
 FEET FROM THE GROUND, MUST PROVIDE AT LEAST 50 PERCENT
 CLEAR GLAZED OF ITS FACADE, BETWEEN TWO AND EIGHT FEET
 FROM THE GROUND.
  
 D.ADDITIONS ON THE FRONTAGE LINE SHALL HAVE CLEAR
 GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF ITS
 FRONT FACADE, BETWEEN TWO AND EIGHT FEET FROM THE
 GROUND AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL
 FRONTAGES.
  
 2. THE LOCATION AND SCREENING FOR THE DUMPSTER MUST
 ALSO BE SHOWN ON THE SITE PLAN.
  
 3. PLEASE INCLUDE A SURVEY WITH THE RESUBMISSION.
  
 4. REPEAT COMMENT:
 PLEASE SHOW THE LOCATION AND SCREENING FOR ALL
 MECHANICAL EQUIPMENT.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-08-30 Cont ID  
Sent By lmartine Date 2010-08-30 Time 15:14 Rev Time 0.00
Received By lmartine Date 2010-08-30 Time 15:14 Sent To  
Notes
2010-08-30 15:15:07SHOW LOCATION AND SCREENING OF A/C UNIT ON THE ROOF IN
 PLAN AND ELEVATION.
  
  
  
 AMY
 822-1442