Plan Review Details - Permit 10080615
Plan Review Stops For Permit 10080615
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-08-25 Cont ID  
Sent By jgomez Date 2010-08-25 Time 16:48 Rev Time 0.00
Received By jgomez Date 2010-08-25 Time 16:48 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-08-23 Cont ID  
Sent By jgomez Date 2010-08-23 Time 13:58 Rev Time 0.00
Received By jgomez Date 2010-08-23 Time 13:57 Sent To  
Notes
2010-08-23 14:17:38RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- FLAT ROOF:
 A) SPECIFY WHICH APPROVED ASSEMBLY FROM NOA 09-0224.01
 SUBMITTED IS GOING TO BE INSTALLED. PRODUCT APPROVAL
 SUBMITTED IS MISSING THE PAGE SHOWING THE APPROVED
 ASSEMBLY.
 ***NOTE: DON'T SELECT ASSEMBLIES WHICH ARE LIMITED BY
 GENERAL LIMITATION #9 BECAUSE THEY DON'T MEET THE
 DESIGN PRESSURES REQUIRED BY SEC. R301.
  
 B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 SUBMITTED.
 ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS TO
 TAKE INTO CONSIDERATION THAT THIS BUILDING IS LOCATED
 ON EXPOSURE "C". SEE SEC. R301.2.1.4.3 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 2- ACCORDING TO THE MIAMI-DADE WEBSITE THE SHINGLES NOA
 07-0306.04 SUBMITTED IS SUPERSEDED. NEED TO PROVIDE
 CURRENT NOA.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-08-23 Cont ID  
Sent By jgomez Date 2010-08-23 Time 13:58 Rev Time 0.00
Received By jgomez Date 2010-08-23 Time 13:58 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved