Plan Review Details - Permit 10080319
Plan Review Stops For Permit 10080319 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-09-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-09-20 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-09-20 |
Time |
13:35 |
Sent To |
|
|
Notes |
2010-09-20 13:37:41 | CERTIFIED TEST & BALANCE REPORT PERFECT BALANCE | | ESPERANTE- ATRIUM | | SMOKE EVACUATION FANS | | 222 LAKEVIEW AVE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-16 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-08-16 |
Time |
07:34 |
Sent To |
|
|
Notes |
2010-08-16 08:22:08 | BUILDING PLAN REVIEW | | PERMIT: 10040209/ REV: 10080319 | | ADD: 222 LAKEVIEW SUITE 120 | | CONT: MIAMI SYSTEMS | | TEL: (561)706-7201 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | REVISION REVIEW: | | DENIED | | REVISION FOR COMMON WALL OF ATRIUM AND TENANT SPACE | | SHOWN AS A NON-RATED WALL. THE DESIGNER IS TAKING | | EXCEPTION# 3 TO FBC-B EXCEPTION# 3 AS DISCUSSED IN | | PREVIOUS MEETING. IN THIS MEETING THE DESIGN TEAM IS | | SUPPOSE TO PRODUCE THE ATRUIM CALCULATIONS IN CUBIC FT | | TO SEE IF THE EXHAUST SYSTEM WAS DESIGNED TO INCLUDE | | THE TENANT SPACES. TO DATE NO CALCULATIONS WERE | | PROVIDED IN EITHER THIS REVISION NOR TO HAROLD MOSER | | MECHANICAL CHIEF WHICH WAS ALSO IN THE SAME MEETING. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-09-15 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-09-15 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-09-15 |
Time |
13:50 |
Sent To |
B |
|
Notes |
2010-09-15 13:50:40 | *****APPROVED***** | | | | MIKE CARSILLO, BATTALION CHIEF | | & WESLEY JOLIN | | WPB FIRE PLAN REVIEW | | 561-805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-08-12 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-08-12 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-08-12 |
Time |
13:57 |
Sent To |
|
|
Notes |
2010-08-12 14:01:31 | ESPERARANTE | | 222 LAKEVIEW AVENUE | | REVISION TRACKING NUMBER 10080319 | | | | 1. PREVIOUS PLAN REVIEW COMMENTS PROVIDED FOR MASTER | | PERMIT NUMBER 10040209 NOT ADDRESSED UNDER REVISION | | TRACKING NUMBER 10080319. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-09-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-09-20 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-09-15 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-09-13 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-09-13 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-13 |
Time |
17:15 |
Sent To |
|
|
Notes |
2010-09-13 17:17:04 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-16 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
10:04 |
Sent To |
|
|
Notes |
2010-08-12 10:04:38 | INCOMING SENT TO FIRE- MC DESK |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |