Plan Review Details - Permit 10080100
Plan Review Stops For Permit 10080100 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-09-02 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-09-02 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-09-02 |
Time |
15:16 |
Sent To |
M |
|
Notes |
2010-09-02 15:17:14 | *****APPROVED***** | | | | MIKE CARSILLO, BATTALION CHIEF | | & WESLEY JOLIN | | WPB FIRE PLAN REVIEW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-08-13 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-08-13 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-08-13 |
Time |
10:46 |
Sent To |
M |
|
Notes |
2010-08-13 15:34:23 | *****REVIEW COMMENTS - FIRE***** | | | | 1) PLANS AND HYDRAULIC CALCULATIONS NOT SIGNED AND | | SEALED BY A PROFESSIONAL ENGINEER. SPRINKLER DESIGN IS | | LESS THAN 50 SPRINKLERS, BUT PLANS WERE SUBMITTED FOR A | | SPRINKLER PERMIT; HOWEVER, SHEET 2 OF 3 (NOTE #4) | | STATES, "FIRE EXTINGUISHING CONTRACTOR SHALL ENGINEER, | | DESIGN..ALL COMPONENTS." PLEASE EXPLAIN. | | | | 2) PROVIDE JOB ADDRESS IN TITLEBLOCK. | | | | 3) PROVIDE LOCKABLE KNOX CAPS ON FIRE DEPARTMENT | | CONNECTION. | | | | 4) WHAT IS THE CHURN PRESSURE OF THE 147 PSI RATED FIRE | | PUMP? WHAT IS THE STATIC PRESSURE OF THE WATER STORAGE | | TANK? SYSTEM PRESSURES MAY BE EXCEEDING 175 PSI. | | | | 5) HYDRAULIC PLACARD INFORMATION: CALCULATED AREA IS | | NOT 3000 SQ.FT. | | | | 6) PROVIDE NOTE ON THE DRAWING INDICATING IF EXPOSED | | STRUCTURE IS OBSTRUCTED CONSTRUCTION OR UNOBSTRUCTED | | CONSTRUCTION, AND INDICATE MIN/MAX SPRINKLER DISTANCE | | ALLOWED BELOW ROOF DECK. | | | | 7) SPRINKLER INFORMATION (TEMPERATURE, K-FACTOR ETC.) | | FROM HYDRAULIC CALCULATIONS NOT SHOWN ON THE PLANS. | | | | MIKE CARSILLO, BATTALION CHIEF | | & WESLEY JOLIN | | WPB FIRE PLAN REVIEW | | 561-805-6730 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-08-25 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-25 |
Time |
17:35 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-08-25 |
Time |
17:35 |
Sent To |
|
|
Notes |
2010-08-25 17:35:41 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-16 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-08-05 |
Time |
12:00 |
Sent To |
|
|
Notes |
2010-08-05 12:00:22 | SENT TO FIRE BOX. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2010-09-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-09-15 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-09-15 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-16 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-08-16 |
Time |
13:07 |
Sent To |
|
|
Notes |
2010-08-16 13:10:12 | PLAN DENIED | | REFER TO FIRE DEPARTMENT COMMENTS #1 AND #2 . | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
|