Plan Review Details - Permit 10080003
Plan Review Stops For Permit 10080003
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-08-12 Cont ID  
Sent By jwitmer Date 2010-08-12 Time 12:50 Rev Time 0.70
Received By jwitmer Date 2010-08-12 Time 12:50 Sent To  
Notes
2010-08-12 12:51:20BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) R319.1 LOCATION REQUIRED. PROTECTION FROM DECAY
 SHALL BE PROVIDED IN THE FOLLOWING
 LOCATIONS BY THE USE OF NATURALLY DURABLE WOOD OR WOOD
 THAT IS PRESERVATIVE TREATED IN
 ACCORDANCE WITH AWPA U1.
 (5). WOOD SIDING, SHEATHING AND WALL FRAMING ON THE
 EXTERIOR OF A BUILDING HAVING A
 CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE
 GROUND.
  
 2) R703.6.3 WHERE CEMENT PLASTER (STUCCO) IS TO BE
 APPLIED TO LATH OVER FRAME
 CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT
 BONDING BETWEEN THE CEMENT PLASTER
 AND THE WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE
 PROVIDED BETWEEN THE WATER-
 RESISTIVE BARRIER AND THE CEMENT PLASTER (STUCCO)
 CONSISTING OF ONE OF THE FOLLOWING:
 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER
 MATERIAL; OR
 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER
 OVER AN APPROVED PLASTIC HOUSE
 WRAP; OR
 3.OTHER APPROVED METHODS OR MATERIALS APPLIED IN
 ACCORDANCE WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-08-12 Cont ID  
Sent By jwitmer Date 2010-08-12 Time 12:51 Rev Time 0.30
Received By jwitmer Date 2010-08-12 Time 12:51 Sent To  
Notes
2010-08-12 12:52:222008 NEC: 410.10 (A) WET LOCATIONS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-08-24 Cont ID  
Sent By lmartine Date 2010-08-19 Time 15:37 Rev Time 0.00
Received By lmartine Date 2010-08-09 Time 10:49 Sent To  
Notes
2010-08-09 10:51:41TO R-16.

Review Stop Z ZONING
Rev No 1 Status P Date 2010-08-19 Cont ID  
Sent By ajones Date 2010-08-19 Time 16:44 Rev Time  
Received By ajones Date 2010-08-19 Time   Sent To  
Notes
***NONE***