Plan Review Stops For Permit 10070802 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2010-10-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-19 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-19 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2010-10-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-10-08 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-10-08 |
Time |
14:56 |
Sent To |
|
|
Notes |
2010-10-08 14:59:36 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) PER FLORIDA STATUES 471 AND F.A.C. 61G15-23.002, THE | | SLAB AND ANCHORING FOR WINDLOAD FROM THE ENGINEER, | | RONALD WILSON, IS REQUIRED TO HAVE THE ORIGINAL | | SIGNATURE AND SEAL OF THE ENGINEER AND THE DATE THAT HE | | SIGNED AND SEALED THE DRAWINGS. | | | | 2) THE EXPOSURE CATEGORY IS INCORRECT ON THE PLANS. IT | | IS LOCATED IN EXPOSURE CATEGORY C. PLEASE CORRECT. | | | | THIS IS THE THIRD TIME THIS PERMIT HAS BEEN DENIED FOR | | THESE SAME TWO COMMENTS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-09-16 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-09-16 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-16 |
Time |
10:20 |
Sent To |
Z |
|
Notes |
2010-09-16 10:21:07 | COMMENTS WERE NOT ADDRESSED. | | | | | | | | | | L.MARTINEZ |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-08-18 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-08-18 |
Time |
14:30 |
Sent To |
Z |
|
Notes |
2010-08-18 14:41:54 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) PER FLORIDA STATUES 471 AND F.A.C. 61G15-23.002, THE | | SLAB AND ANCHORING FOR WINDLOAD FROM THE ENGINEER, | | RONALD WILSON, IS REQUIRED TO HAVE THE ORIGINAL | | SIGNATURE AND SEAL OF THE ENGINEER AND THE DATE THAT HE | | SIGNED AND SEALED THE DRAWINGS. | | | | 2) THE EXPOSURE CATEGORY IS INCORRECT ON THE PLANS. IT | | IS LOCATED IN EXPOSURE CATEGORY C. PLEASE CORRECT. | | | | 3) PER NFPA 37, THE GENERATOR MUST BE LOCATED A MINIMUM | | OF 5 FEET FROM OPENINGS IN WALLS AND 5 FEET FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS. GENERATORS SHALL | | BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S | | INSTALLATION INSTRUCTIONS AND NFPA 37. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-09-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2010-09-15 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-09-15 |
Time |
15:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2010-08-18 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-08-18 |
Time |
14:20 |
Sent To |
B |
|
Notes |
2010-08-18 14:22:36 | NEED TO SUPPLY A LOAD CALCULATION PER 702.5 (B) | | | | IS METER AT SAME LOCATION AS PANEL "A" | | | | IF MAINS ARE NOT GROPUPED PER 230.71 A SIGN PER 702.8 | | SHALL BE INSTALLED. | | | | J LEAHY |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-08-18 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-08-18 |
Time |
14:45 |
Sent To |
|
|
Notes |
2010-08-18 14:45:58 | A SEPARATE PERMIT AND PLANS ARE REQUIRED FOR GAS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2010-10-18 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-10-18 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-10-18 |
Time |
13:58 |
Sent To |
|
|
Notes |
2010-10-18 13:59:45 | GAVE TO ROBBIE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-09-23 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-09-23 |
Time |
16:51 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-23 |
Time |
16:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-09-16 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-09-08 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-09-08 |
Time |
17:28 |
Sent To |
|
|
Notes |
2010-09-08 17:28:52 | GEN RES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-09-07 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-31 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-07-29 |
Time |
12:53 |
Sent To |
|
|
Notes |
2010-08-18 10:36:56 | GAVE TO J.LEAHY | 2010-07-29 12:54:58 | INCOMING SENT TO RES GEN BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2010-09-27 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-09-27 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-09-17 |
Time |
16:34 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-08-31 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-08-31 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-08-20 |
Time |
14:12 |
Sent To |
I |
|
Notes |
2010-08-31 18:18:12 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PROVIDE DIMENSIONS FROM THE GENERATOR (EQUIPMENT) TO | | ALL PROPERTY LINES ON THE SURVEY. PURSUANT TO SECTION | | 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|