Plan Review Stops For Permit 10070561 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2011-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-06-28 |
Time |
13:05 |
Rev Time |
1.10 |
Received By |
jwitmer |
Date |
2011-06-28 |
Time |
12:34 |
Sent To |
|
|
Notes |
2011-06-28 12:37:21 | | | BUILDING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | BUILDING PROVISO: | | | | 1) CONTRACTOR TO SIGN ONTO PERMIT, FRONT COUNTER TO | | VERIFY LICENSURE. | | | | 2) AT THIS TIME THE FUTURE CONTRACTOR HAS NOT SUBMITTED | | PRODUCT APPROVALS. IF PRODUCT TESTING APPROVALS ARE NOT | | SUBMITTED BEFORE ISSUANCE THEN THE | | SUBMISSION OF TESTING REPORTS WILL CONSTITUTE A | | REVISION AND ASSOCIATED REVIEWS AND FEES. | | FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2 | | COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE | | AS FOLLOWS: | | 2A) SINGLE HUNG WINDOWS | | 2B) CASEMENT WINDOWS | | 2C) EXTERIOR DOORS | | 2D) ROOFING ASSEMBLIES | | 2E) STORM SHUTTERS, IF GLAZED OPENINGS ARE NOT LARGE | | MISSILE RESISTANT TESTED | | 2F) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 3) GAS PERMIT WILL BE REQUIRED FOR THE NEW GAS INSTANT | | HOT WATER HEATER, NOT PART OF THIS REVIEW. | | | | JAMES A. WITMER C.B.O. | | COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: (561)805-6715 | | FAX:(561)805-6731 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2011-04-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-04-18 |
Time |
09:38 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2011-04-18 |
Time |
09:38 |
Sent To |
|
|
Notes |
2011-04-18 09:46:17 | BUILDING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 4TH REVIEW | | ACTION: DENIED | | | | | | 1-3) COMPLIED. | | | | | | 4) 106.3.3 THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 5A) COMPLIED.WINDOWS/ SINGLE HUNG - RULE 9B-72(31) (B) | | NOA 080820.14 | | WINDOWS/ CASEMENT RULE 9B-72(31) (B) NO APPROVALS WERE | | SUBMITTED | | | | 5B) COMPLIED.EXTERIOR DOORS RULE 9B-72(31) (A) NEW RULE | | 9N-3 FL 4334.1 | | 5C) ROOF ASSEMBLIES RULE 9B-72(31) (D) NEW RULE 9N-3 NO | | APPROVALS WERE SUBMITTEDCAN BE ISSUED UNDER A SEPERATE | | ROOFING PERMIT. | | 5D) NOT REQUIRED | | | | PLEASE NOTE IF THE CONTRACTOR DOES NOT SUPPLY THE | | PRODUCT APPROVALS BEFORE TIME OF ISSUANCE, THESE ITEMS | | CAN BE A BUILDING PROVISO: WHICH MEANS THE PRODUCT | | APPROVALS CAN BE BROUGHT IN AFTER ISSUANCE BUT WILL BE | | CONSIDERED A REVISION WITH FURTHER REVIEW AND | | ASSOCIATED FEES. THE DESIGN PRESSURES INDICATED ON | | SHEET 5.1 ARE CORRECT. | | | | 6-8) COMPLIED. | | | | 9) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 10) IMPACT FEES : COMPLIED. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2011-03-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-03-30 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-03-30 |
Time |
08:35 |
Sent To |
|
|
Notes |
2011-03-30 08:39:01 | BUILDING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 3RD REVIEW | | ACTION: DENIED | | | | | | 1-3) COMPLIED. | | | | | | 4) NO PRODUCT APPROVALS WERE SUBMITTED. 106.3.3 PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 5A) WINDOWS RULE 9B-72(31) (B) | | SINGLE HUNG | | CASEMENT | | 5B) EXTERIOR DOORS RULE 9B-72(31) (A) NEW RULE 9N-3 | | 5C) ROOF ASSEMBLIES RULE 9B-72(31) (D) NEW RULE 9N-3 | | 5D) STORM SHUTTERS/ PANELS 9B-72(31)(E) NEW RULE 9N-3 | | | | PLEASE NOTE IF THE CONTRACTOR DOES NOT SUPPLY THE | | PRODUCT APPROVALS BEFORE TIME OF ISSUANCE, THESE ITEMS | | CAN BE A BUILDING PROVISO: WHICH MEANS THE PRODUCT | | APPROVALS CAN BE BROUGHT IN AFTER ISSUANCE BUT WILL BE | | CONSIDERED A REVISION WITH FURTHER REVIEW AND | | ASSOCIATED FEES. THE DESIGN PRESSURES INDICATED ON | | SHEET 5.1 ARE CORRECT. | | | | 6-8) COMPLIED. | | | | 9) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2011-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-03 |
Time |
10:50 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
2011-02-03 |
Time |
09:40 |
Sent To |
|
|
Notes |
2011-02-03 11:03:12 | BUILDING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | NOTE SHEET 1.1 INDICATES A TWO STORY TO BE REMODELED | | THERE ARE NO OTHER REFERENCES IN EITHER THIS PLAN NOR | | PERMIT APPLICATION AND WILL NOT BE PART OF WORK TO BE | | COMPLETED UNDER THIS PERMIT . | | | | 1) EITHER A CONTRACTOR OR OWNER/ BUILDER WILL BE | | REQUIRED TO SIGN ON TO THE PERMIT APPLICATION. | | | | 2) COMPLIED, TWO SETS OF PLANS. | | | | 3) SEMI-COMPLIED. THE PLANS ARE DESIGNED BY RICHARD | | BOYETTE A FL PE, PE# 42485, PLANS ARE NOT SIGNED NOR | | SEALED. | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | | | | | | 4) NO PRODUCT APPROVALS WERE SUBMITTED. 106.3.3 PRODUCT | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | DCA RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 5A) WINDOWS RULE 9B-72(31) (B) | | SINGLE HUNG | | CASEMENT | | 5B) EXTERIOR DOORS RULE 9B-72(31) (A) NEW RULE 9N-3 | | 5C) ROOF ASSEMBLIES RULE 9B-72(31) (D) NEW RULE 9N-3 | | 5D) STORM SHUTTERS/ PANELS 9B-72(31)(E) NEW RULE 9N-3 | | | | PLEASE NOTE IF THE CONTRACTOR DOES NOT SUPPLY THE | | PRODUCT APPROVALS BEFORE TIME OF ISSUANCE, THESE ITEMS | | CAN BE A BUILDING PROVISO: WHICH MEANS THE PRODUCT | | APPROVALS CAN BE BROUGHT IN AFTER ISSUANCE BUT WILL BE | | CONSIDERED A REVISION WITH FURTHER REVIEW AND | | ASSOCIATED FEES. THE DESIGN PRESSURES INDICATED ON | | SHEET 5.1 ARE CORRECT. | | | | 6) 2ND REQUEST, SHEET 3.1 IN THE DESIGN PARAMETERS AND | | CODE REFERENCES, BOTH MAKE REFERENCES TO THE 2004 FBC, | | PLEASE REVISE TO THE 2007 FBC WITH 2009 SUPPLEMENTS. | | PLEASE ALSO INCLUDE UNDER THE 2007 EXISTING BUILDING | | CODE COMPLIANCE WITH SECTION 401.4 A DESIGN | | PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A | | COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 403, 404 AND 405 OF THIS CODE. | | | | 7-8) COMPLIED. | | | | 9) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-12 |
Time |
10:59 |
Rev Time |
3.30 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
10:59 |
Sent To |
|
|
Notes |
2010-08-12 11:00:07 | | | BUILDING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | NOTE SHEET 1.1 INDICATES A TWO STORY TO BE REMODELED | | THERE ARE NO OTHER REFERENCES IN EITHER THIS PLAN NOR | | PERMIT APPLICATION AND WILL NOT BE PART OF WORK TO BE | | COMPLETED UNDER THIS PERMIT . | | | | 1) EITHER A CONTRACTOR OR OWNER/ BUILDER WILL BE | | REQUIRED TO SIGN ON TO THE PERMIT APPLICATION. | | | | 2) NOTE, ONLY ONE SET OF PLANS WERE SUBMITTED TO REVIEW | | FOR CODE COMPLIANCE. BEFORE A PERMIT WILL BE ISSUED TWO | | SETS OF PLANS AND ASSOCIATED DOCUMENTS WILL NEED TO BE | | SUPPLIED FOR REVIEW AND APPROVAL STAMPING. ONE FOR THE | | FIELD INSPECTORS AND ONE FOR RECORD RETENTION. 106.3.1/ | | 2007 FBC-B ADMINISTRATIVE CODE. | | | | 3) PLEASE PROVIDE ON THE PLANS WHO IS THE DESIGNER OF | | RECORD, SINCE THIS IS A SINGLE FAMILY RESIDENCE IT DOES | | NOT NEED TO BE A ARCHITECT OR ENGINEER WHO ARE COVERED | | UNDER FL S 481 AND 471. FBC-B 106.1* DESIGNERS NAME AND | | CONTACT NUMBER TO BE ABLE TO CONTACT THE DESIGNER IN | | CASE OF QUESTIONS. | | | | 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, | | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING | | REPORTS ARE AS FOLLOWS: | | 5A) WINDOWS RULE 9B-72(31) (B) | | SINGLE HUNG | | CASEMENT | | 5B) EXTERIOR DOORS RULE 9B-72(31) (A) | | 5C) ROOF ASSEMBLIES RULE 9B-72(31) (D) | | | | PLEASE NOTE IF THE CONTRACTOR DOES NOT SUPPLY THE | | PRODUCT APPROVALS BEFORE TIME OF ISSUANCE, THESE ITEMS | | CAN BE A BUILDING PROVISO: WHICH MEANS THE PRODUCT | | APPROVALS CAN BE BROUGHT IN AFTER ISSUANCE BUT WILL BE | | CONSIDERED A REVISION WITH FURTHER REVIEW AND | | ASSOCIATED FEES. THE DESIGN PRESSURES INDICATED ON | | SHEET 5.1 ARE CORRECT. | | | | 6) SHEET 3.1 IN THE DESIGN PARAMETERS AND CODE | | REFERENCES, BOTH MAKE REFERENCES TO THE 2004 FBC, | | PLEASE REVISE TO THE 2007 FBC WITH 2009 SUPPLEMENTS. | | PLEASE ALSO INCLUDE UNDER THE 2007 EXISTING BUILDING | | CODE COMPLIANCE WITH SECTION 401.4 A DESIGN | | PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A | | COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 403, 404 AND 405 OF THIS CODE. | | | | 7) THE FLOOR PLAN SHEET 3.1 INDICATES A NEWLY REMODELED | | RESTROOM WITH THE SHOWER NEXT TO A SINGLE HUNG WINDOW | | PLEASE REVIEW R308.4(9) HAZARDOUS LOCATIONS. | | | | 8) THE PLANS INDICATE IN SECTION 3/6.1 A TYPICAL GABLE | | WALL PLEASE REVIEW R602.1.2(1.1) FOR REQUIRED FIRE | | BLOCKING SEPARATING VERTICALLY AT THE CEILING. | | | | 9) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-03-23 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-03-23 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-03-23 |
Time |
09:00 |
Sent To |
|
|
Notes |
2011-03-23 09:03:29 | PROVISO ON PLANS: | | | | A CARBON DIOXIDE ALARM IS REQUIRED IN ACCORDANCE WITH | | THE FLORIDA BUILDING CODE SECTION R313.2.1 FOR | | RESIDENTIAL BUILDINGS UNDER GOING REPAIRS AND | | ALTERATIONS. | | | | NEW GENERAL PURPOSE RECEPTACLES MUST BE PROTECTED WITH | | AFCI'S. NEC 210.12(B) | | | | BATHROOM RECEPTACLES MUST HAVE GFCI PROTECTION. NEC | | 210-8 (A) | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-08-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2010-08-10 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2010-08-10 |
Time |
09:43 |
Sent To |
|
|
Notes |
2010-08-10 09:43:55 | OK PER JOHN DICKINSON (CONTRACT REVIEWER) | | PX3182 | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2011-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-03 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-02-03 |
Time |
11:07 |
Sent To |
|
|
Notes |
2011-02-03 11:09:15 | A SEPERATE GAS PERMIT WILL BE REQUIRED NOT TO BE | | INCLUDED UNDER THE MASTER. | | | | REQUIRED INFORMATION FOR GAS PERMIT: | | | | 1) PLEASE PROVIDE THE DEVELOPED LENGTH OF THE GAS | | PIPING FROM THE METER TO THE LAST APPLIANCE, BTU OF | | EACH APPLIANCE. | | | | 1A) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2007 RESIDENTIAL OR | | 2007 FUEL GAS CODE. | | SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (METER), | | TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER FBC-2007 FUEL | | GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | 1B) 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, | | ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL TUBING FOR EACH | | PIPE SIZE IF BEING USED. | | | | 1C) NEW GAS INSTA-HOT WATER HEATER PLEASE PROVIDE | | MANUFACTURERS SPEC FOR BTU, AND APPROVAL FOR EXTERIOR | | LOCATIONS. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA 58, AND THE FBC-2007 FUEL GAS CODE SEC 402.2 & | | RESIDENTIAL CODE SEC. G2413.2. | | | | 1D) BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD | | ON THE SYSTEM. REFER TO | | THE FBC-2007 FUEL GAS CODE SECS. 401.8 THRU 402.6.1 AND | | TABLES 402.4(1) THRU | | 402.4(33) OR RESIDENTIAL CODE SECTIONS G2412.8 THRU | | G2413.6.1 AND TABLES G2413.4(1) THRU 2413.4(8). | | | | 1E) INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2004 | | FUEL GAS CODE SEC. 402.2. NATURAL GAS SPECIFY .5 PSI OR | | 2 PSI. | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2010-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-12 |
Time |
11:23 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
11:23 |
Sent To |
|
|
Notes |
2010-08-12 11:37:25 | GAS PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE- GAS | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE THE DEVELOPED LENGTH OF THE GAS | | PIPING FROM THE METER TO THE LAST APPLIANCE, BTU OF | | EACH APPLIANCE. | | | | 1A) SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2007 RESIDENTIAL OR | | 2007 FUEL GAS CODE. | | SHOW THE DISTANCE FROM THE POINT OF DELIVERY, (METER), | | TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER FBC-2007 FUEL | | GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | 1B) 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, | | ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL TUBING FOR EACH | | PIPE SIZE IF BEING USED. | | | | 1C) NEW GAS INSTA-HOT WATER HEATER PLEASE PROVIDE | | MANUFACTURERS SPEC FOR BTU, AND APPROVAL FOR EXTERIOR | | LOCATIONS. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA 58, AND THE FBC-2007 FUEL GAS CODE SEC 402.2 & | | RESIDENTIAL CODE SEC. G2413.2. | | | | 1D) BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD | | ON THE SYSTEM. REFER TO | | THE FBC-2007 FUEL GAS CODE SECS. 401.8 THRU 402.6.1 AND | | TABLES 402.4(1) THRU | | 402.4(33) OR RESIDENTIAL CODE SECTIONS G2412.8 THRU | | G2413.6.1 AND TABLES G2413.4(1) THRU 2413.4(8). | | | | 1E) INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2004 | | FUEL GAS CODE SEC. 402.2. NATURAL GAS SPECIFY .5 PSI OR | | 2 PSI. | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
4 |
Status |
P |
Date |
2011-06-20 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2011-06-20 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2011-06-20 |
Time |
14:08 |
Sent To |
|
|
Notes |
2011-06-20 14:09:08 | NO VINYL WINDOWS. MUST BE PGT AS SPEC'D ON PLANS OR | | APPROVED BY HISTORIC PRESERVATION DIVISION STAFF/BOARD. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2011-04-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2011-04-04 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2011-04-04 |
Time |
10:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2011-01-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2011-01-28 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2011-01-28 |
Time |
17:17 |
Sent To |
|
|
Notes |
2011-01-28 17:18:03 | HISTORIC APPROVED 1-28-11. BROUGHT PLANS TO LUIS M. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2010-08-18 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2010-08-18 |
Time |
13:02 |
Sent To |
|
|
Notes |
2010-08-18 13:08:45 | PLANS FAILED BECAUSE NORTH ELEVATION WINDOWS EXTEND | | BELOW LOCATION OF ORIGINAL WINDOW SIZE PER HISTORIC | | PRESERVATION BOARD APPROVAL ON 9/23/08 FOR CASE 08-40. | | | | FRIEDERIKE MITTNER, CITY HISTORIC PRESERVATION PLANNER | | 822-1457 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2011-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-06-28 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-06-07 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2011-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-04-18 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-04-14 |
Time |
16:45 |
Sent To |
|
|
Notes |
2011-04-14 16:45:24 | GAVE TO JIM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2011-04-14 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-04-08 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-03-21 |
Time |
11:42 |
Sent To |
|
|
Notes |
2011-03-21 11:42:42 | SENT TO R21 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-02-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-12-21 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-12-21 |
Time |
13:44 |
Sent To |
|
|
Notes |
2011-02-02 13:48:59 | RESUBMITTAL WAS INCORRECTLY SUBMITTED AS A NEW | | APPLICATION #10120533. THAT # HAS SINCE BEEN VOIDED AND | | THE RESUBMIITAL WILL CONTINUE UNDER THIS PERMIT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-02-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-18 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-07-28 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2011-04-08 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-04-08 |
Time |
12:27 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-04-08 |
Time |
12:27 |
Sent To |
|
|
Notes |
2011-04-08 12:31:43 | FEES PAID PBC RECEIPT # 2011-0408-99 NEED PLAN STAMPED. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2010-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-12 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2011-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-06-28 |
Time |
12:32 |
Rev Time |
0.35 |
Received By |
jwitmer |
Date |
2011-06-28 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2011-03-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-03-30 |
Time |
08:41 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
2011-03-30 |
Time |
08:41 |
Sent To |
|
|
Notes |
2011-03-30 08:42:10 | MECHANICAL PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE- MECHANICAL | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 3RD REVIEW | | ACTION: DENIED | | | | 1) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 2) SHEET 6.1 MECHANICAL SHEET IS MISSING THE A/C SYSTEM | | DESIGN DATA, BLANK! | | | | | | JAMES A. WITMER C.B.O. | | SFP-100 | | COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: (561)805-6715 | | FAX:(561)805-6731 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2011-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-03 |
Time |
11:11 |
Rev Time |
0.35 |
Received By |
jwitmer |
Date |
2011-02-03 |
Time |
11:11 |
Sent To |
|
|
Notes |
2011-02-03 11:15:58 | MECHANICAL PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE- MECHANICAL | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | 1) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 2) SHEET 6.1 MECHANICAL SHEET IS MISSING THE A/C SYSTEM | | DESIGN DATA, BLANK! | | | | | | JAMES A. WITMER C.B.O. | | SFP-100 | | COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: (561)805-6715 | | FAX:(561)805-6731 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-08-12 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-12 |
Time |
11:09 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
11:09 |
Sent To |
|
|
Notes |
2010-08-12 11:23:18 | | | | | | | | | | | MECHANICAL PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE- MECHANICAL | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | | | 1) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. | | N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL | | BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION | | AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD | | A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN | | APPLICABLE (SEE SECTION N1100.7.3), MEET THE | | PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR | | INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND | | EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING | | RETROFITTED OR REPLACED. | | | | 2) PROVISO: M1602.4 BALANCED RETURN AIR. RESTRICTED | | RETURN AIR OCCURS IN BUILDINGS WHEN RETURNS ARE LOCATED | | IN CENTRAL ZONES AND CLOSED INTERIOR DOORS IMPEDE AIR | | FLOW TO THE RETURN GRILL OR WHEN CEILING SPACES ARE | | USED AS RETURN PLENUMS AND FIRE WALLS RESTRICT AIR | | MOVEMENT FROM ONE PORTION OF THE RETURN PLENUM TO | | ANOTHER. PROVISIONS SHALL BE MADE IN RESIDENTIAL | | BUILDINGS TO AVOID UNBALANCED AIR FLOWS AND PRESSURE | | DIFFERENTIALS CAUSED BY RESTRICTED RETURN AIR. PRESSURE | | DIFFERENTIALS ACROSS CLOSED DOORS WHERE RETURNS ARE | | CENTRALLY LOCATED SHALL BE LIMITED TO 0.01 INCH WC (2.5 | | PA) OR LESS. PRESSURE DIFFERENTIALS ACROSS FIRE WALLS | | IN CEILING SPACE PLENUMS SHALL BE LIMITED TO 0.01 INCH | | WC (2.5 PA) BY PROVIDING AIR DUCT PATHWAYS OR AIR | | TRANSFER PATHWAYS FROM THE HIGH PRESSURE ZONE TO THE | | LOW ZONE. | | | | EXCEPTIONS: | | | | 1. TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | HAVING AT LEAST AN UNRESTRICTED 1 INCH (25 MM) UNDERCUT | | TO ACHIEVE PROPER RETURN AIR BALANCE. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2011-03-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-03-30 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-03-30 |
Time |
08:39 |
Sent To |
|
|
Notes |
2011-03-30 08:40:34 | GAS WILL REQUIRE A SEPERATE PERMIT, REVIEW AND | | ASSOCIATED FEES. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2011-02-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-02-03 |
Time |
11:18 |
Rev Time |
0.25 |
Received By |
jwitmer |
Date |
2011-02-03 |
Time |
11:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-08-16 |
Time |
10:56 |
Rev Time |
0.88 |
Received By |
jwitmer |
Date |
2010-08-12 |
Time |
11:37 |
Sent To |
|
|
Notes |
2010-08-16 11:00:32 | PLUMBING PLAN REVIEW | | PERMIT: 10070561 | | ADD: 716 NEY YORK ST | | CONT: TO BE DETERMINED | | CONTACT: PENE LATHAM | | TEL: (561)832-1500 | | | | FL BLD CODE PLUMBING= 2007 FLORIDA BUILDING CODE- | | PLUMBING | | W/ 2009 FBC SUPPLEMENTS * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET 6.1 ISOMETRIC PLAN THE NEW BATHROOM INDICATES | | A WATERCLOSET AND SHOWER CONNECTED TO THE SAME STACK. | | PLEASE REVIEW P3107.3 CONNECTIONS AT DIFFERENT LEVEL. | | THE UPPER FIXTURE SHALL NOT BE A WATER CLOSET. | | CURRENTLY SHOWN THE SHOWER IS NOT VENTED. | | | | 2) THE KITCHEN THE PLANS INDICATE WINDOWS REQUIRING THE | | VENT TO BE ROUTED PAST THE FRAMED WINDOW OPENING. | | R602.2.7 DRILLING AND NOTCHING???STUDS. DRILLING AND | | NOTCHING OF STUDS SHALL BE IN ACCORDANCE WITH THE | | FOLLOWING: | | | | 1.NOTCHING. ANY STUD IN AN EXTERIOR WALL OR BEARING | | PARTITION MAY BE CUT OR NOTCHED TO A DEPTH NOT | | EXCEEDING 25 PERCENT OF ITS WIDTH. STUDS IN NONBEARING | | PARTITIONS MAY BE NOTCHED | | TO A DEPTH NOT TO EXCEED 40 PERCENT OF A SINGLE STUD | | WIDTH. | | | | 2. DRILLING. ANY STUD MAY BE BORED OR DRILLED, PROVIDED | | THAT THE DIAMETER OF THE RESULTING HOLE IS NO MORE THAN | | 60 PERCENT OF THE STUD WIDTH, THE EDGE OF THE HOLE IS | | NO MORE THAN 5/8 | | INCH (16 MM) TO THE EDGE OF THE STUD, AND THE HOLE IS | | NOT LOCATED IN THE SAME SECTION AS A CUT OR NOTCH. | | STUDS LOCATED IN EXTERIOR WALLS OR BEARING PARTITIONS | | DRILLED OVER 40 PERCENT | | AND UP TO 60 PERCENT SHALL ALSO BE DOUBLED WITH NO MORE | | THAN TWO SUCCESSIVE DOUBLED STUDS BORED. SEE FIGURES | | R602.2.7(1) AND R602.2.7(2). | | | | PLEASE NOTE AN AIR ADMITTANCE DEVICE MAY BE USED | | INSTEAD OF THE 2 INCH VENT. | | | | 3) WITHIN THE NEW HALF BATH THE SANITARY VENT WILL | | EITHER CUT OR NOTCH THE TOP AND BOTTOM PLATE PLEASE | | REVIEW SECTION: R602.2.7.1 DRILLING AND NOTCHING OF TOP | | PLATE. WHEN PIPING OR DUCTWORK IS PLACED IN OR PARTLY | | IN AN EXTERIOR WALL OR INTERIOR LOAD-BEARING WALL, | | NECESSITATING CUTTING, DRILLING OR NOTCHING OF THE TOP | | PLATE BY MORE THAN 50 PERCENT OF ITS WIDTH, A | | GALVANIZED METAL TIE OF NOT LESS THAN 0.054 INCHES | | THICK (1.37 MM) (16 GA) AND 11/2 INCHES (38 MM) WIDE | | SHALL BE FASTENED ACROSS AND TO THE PLATE AT EACH SIDE | | OF THE OPENING WITH NOT LESS THAN EIGHT 10D (0.148 INCH | | DIAMETER) NAILS HAVING A MINIMUM LENGTH OF 11/2 INCHES | | (38 MM) AT EACH SIDE OR EQUIVALENT. SEE FIGURE | | R602.2.7(1). | | EXCEPTION: WHEN THE ENTIRE SIDE OF THE WALL WITH THE | | NOTCH OR CUT IS COVERED BY WOOD STRUCTURAL PANEL | | SHEATHING. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2011-06-27 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-06-27 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-06-27 |
Time |
17:09 |
Sent To |
|
|
Notes |
2011-06-27 17:09:41 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 06.27.2011 | | PERMIT NO.: 10070561 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: RENOVATIONS AND ADDITIONS TO EXISTING | | SINGLE FAMILY HOUSE. | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. AS THE EXISTING STRUCTURE DOES NOT MEET THE CURRENT | | SETBACK REQUIREMENTS, IF ANY REBUILDING OF THE EXTERIOR | | WALLS, ETC. IS DEEMED NECESSARY OUTSIDE OF THE APPROVED | | SCOPE OF THIS PERMIT, A REVISION TO THE PERMIT WILL BE | | REQUIRED, AND MAY REQUIRE APPROVAL OF A VARIANCE BY THE | | ZONING BOARD OF APPEALS (ZBA)! | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2011-04-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-04-04 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-04-04 |
Time |
18:27 |
Sent To |
|
|
Notes |
2011-04-04 18:36:29 | ZONING PLAN REVIEW | | | | PERMIT NO.: 10070561 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: PENE LATHAM | | TELEPHONE NO.: 561.832.1500 | | SCOPE OF REVIEW: REMODEL OF MAIN HOUSE | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | SHALL BE PROVIDED. | | | | IMPORTANT - AS THE PROPOSED STRUCTURE DOES NOT MEET THE | | CURRENT SETBACK REQUIREMENTS, A NOTE WILL BE ADDED TO | | THE PERMIT INDICATING THAT IF ANY REBUILDING OF THE | | EXTERIOR WALLS, ETC. IS DEEMED NECESSARY, A REVISION TO | | THE PERMIT WILL BE REQUIRED, AND MAY REQUIRE THE | | APPROVAL OF A VARIANCE FROM THE ZONING BOARD OF | | APPEALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2011-02-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-02-07 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-02-07 |
Time |
10:54 |
Sent To |
|
|
Notes |
2011-02-07 11:03:43 | ZONING PLAN REVIEW | | | | PERMIT NO.: 10070561 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: PENE LATHAM | | TELEPHONE NO.: 561.832.1500 | | SCOPE OF REVIEW: REMODEL OF MAIN HOUSE | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | SHALL BE PROVIDED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2010-08-18 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2010-08-18 |
Time |
10:15 |
Sent To |
|
|
Notes |
2010-08-18 10:15:33 | ZONING PLAN REVIEW | | | | PERMIT NO.: 10070561 | | ADDRESS: 716 NEW YORK STREET | | CONTRACTOR/CONTACT: PENE LATHAM | | TELEPHONE NO.: 561.832.1500 | | SCOPE OF REVIEW: REMODEL OF MAIN HOUSE | | | | REVIEW STATUS: FAILED | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1) TWO (2) SETS OF ALL PLANS SHALL BE PROVIDED. | | | | 2) TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | SHALL BE PROVIDED. | | | | 3) PURSUANT TO SECTION 94-305(B)(2) OF THE CITY???S | | ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS), THE | | ROOF OVERHANG OF THE PROPOSED BATHROOM ADDITION SHALL | | NOT EXTEND MORE THAN THREE (3) FEET INTO THE REQUIRED | | SETBACK. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|