Plan Review Stops For Permit 10070522 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-07-27 |
Time |
11:18 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-07-27 |
Time |
10:45 |
Sent To |
|
|
Notes |
2010-07-27 11:37:06 | BUILDING PLAN REVIEW | | PERMIT: 10070522 | | ADD: 1400 NORTHPOINT, SUITE P | | CONT: P & T CONSTRUCTION | | TEL: (561)833-0614 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | 1) SHEETS A1.2 & A4.2 THE NEW EXTERIOR DOOR NEEDS TO | | COMPLY WITH 11-4.13.6. A 18 INCH CLEAR SPACE LATCH SIDE | | OF DOOR. MANEUVERING CLEARANCES AT DOORS. MINIMUM | | MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC | | OR POWER-ASSISTED SHALL BE AS SHOWN IN FIGURE 25. THE | | FLOOR OR GROUND AREA WITHIN THE REQUIRED CLEARANCES | | SHALL BE LEVEL AND CLEAR. | | | | 2) A1.2 & A4.2 NEW EXTERIOR DOOR PROVIDE NEW WALL / | | COLUMN DETAIL, PRODUCT APPROVAL FOR NEW EXTERIOR DOOR & | | WIND DESIGN CRITERIA INCLUDING PRESSURES. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-08-09 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-09 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-08-09 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-08-30 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-08-30 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-08-30 |
Time |
14:06 |
Sent To |
|
|
Notes |
2010-08-30 14:08:42 | 1400 NORTHPOINT PARKWAY | | PERMIT NUMBER 10070522 | | | | | | A RESPONSE LETTER AND DRAWINGS FOR FIRE SPRINKLER AND | | FIRE ALARM SYSTEM WORK SUBMITTED BY JEFF CONTE OF P & T | | CONSTRUCTION. | | | | SEPARATE PLANS AND PERMITS EXPECTED FOR FIRE SPRINKLER | | AND FIRE ALARM SYSTEMS. | | | | | | APPROVED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-07-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-07-29 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-07-29 |
Time |
15:01 |
Sent To |
|
|
Notes |
2010-07-29 15:22:56 | 1400 NORTHPOINT PARKWAY, SUITE P | | PERMIT NUMBER 10070522 | | TENANT IMPROVEMENT BUILD-OUT OF APPROXIMATELY 7,000 | | SQUARE FEET | | | | | | 1. DEMOLITION, RENOVATION, AND CONSTRUCTION TO COMPLY | | WITH NFPA 241. | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR ANY FIRE | | SPRINKLER SYSTEM REMODELING. | | | | 3. SEPARATE PLANS AND PERMITS REQUIRED FOR NEW LOW | | VOLTAGE WORK. | | | | 4. PLEASE ENSURE THAT ALL EXISTING EMERGENCY LIGHTS AND | | EXIT SIGNS AND ILLUMINATED EXIT SIGNS ARE FUNCTIONING | | PROPERLY. | | | | 5. ELECTRICAL INSTALLATION TO COMPLY WITH NFPA 70, THE | | NATIONAL ELECTRIC CODE. | | | | 6. MORE DETAILS NEEDED ON SECURITY SYSTEM AND DEVICES. | | LOCKING DEVICES SHALL NOT INTERFERE WITH ANY REQUIRED | | EXIT ACCESS OR EXIT DISCHARGE. | | | | 7. DOES ANY FIRE ALARM EQUIPMENT EXIST? | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-08-25 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-25 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-08-25 |
Time |
12:36 |
Sent To |
|
|
Notes |
2010-08-25 12:36:56 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-08-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-17 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-07-23 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-08-17 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-17 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-08-17 |
Time |
12:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-07-28 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-07-28 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-07-28 |
Time |
12:22 |
Sent To |
|
|
Notes |
2010-07-28 12:51:31 | *****NOTE***** | | | | CONDENSATE SHALL NOT BE CONNECTED TO ANY VENT. | | CONDENSATE SHALL BE RUN TO AN APPROVED PLACE OF | | DISPOSAL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2010-07-29 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2010-07-29 |
Time |
08:40 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2010-07-29 |
Time |
08:40 |
Sent To |
|
|
Notes |
2010-07-29 08:41:37 | INTERIOR WORK ONLY. PERMIT VALUE FOR PAST 12 MONTHS | | UNDER 50% OF BUILDING VALUE. |
|
|