Plan Review Details - Permit 10070135
Plan Review Stops For Permit 10070135
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2011-03-14 Cont ID  
Sent By jwitmer Date 2011-03-14 Time 14:49 Rev Time 0.00
Received By jwitmer Date 2011-03-14 Time 14:49 Sent To  
Notes
2011-03-14 14:51:03NEW A-3 SHEET BUILDING DID NOT STAMP SHEET DEPENDING ON
 ENGINEERING AND ZONING REVIEW.
 ZONING ALSO STILL HAS ONE SET OF PLANS. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-01-13 Cont ID  
Sent By jwitmer Date 2011-01-13 Time 13:16 Rev Time 0.00
Received By jwitmer Date 2011-01-13 Time 13:10 Sent To  
Notes
2011-01-13 13:15:4401/12/2011 @ 9;00 AM, MEETING HELD WITH OWNER,
 CONTRACTOR, ARCHITECT AND MYSELF DISCUSSED
 ACCESSIBILITY ISSUES, WILL APPEAR TO BE CODE COMPLIANT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-11-01 Cont ID  
Sent By jwitmer Date 2010-11-01 Time 10:26 Rev Time 0.77
Received By jwitmer Date 2010-11-01 Time 10:26 Sent To  
Notes
2010-11-01 10:44:28BUILDING PLAN REVIEW
 PERMIT: 10070135
 ADD: 425 25TH ST
 CONT: CRL CONSTRUCTION
 TEL: (561)248-7177
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2NDREVIEW
 ACTION: DENIED
  
 1) THE FIRST REVIEW BUILDING PROVIDED A PASSED WITH
 PROVISO WHICH DELT WITH THE INCREASING THE
 RESTROOM DOORS TO ACCESSIBLE 2'-8" CLEAR DOORWAYS. THE
 PLANS WHEN SUBMITTED ON SECOND REVIEW STILL INDICATE
 THE 2'-6" DOORWAYS.
  
 I HAVVE SPOKEN TO THE DESSIGNER OF RECORD ONCE ON THE
 MATTERWHICH ENDED UP NEEDING TO TALK WITH THE BUILDING
 OFFICIAL DOUG WISE FOR HIS INTERPRETATION ON THE
 ACCESSIBILITY ISSUES.
  
 THE CONTRACTOR AND OR DESIGNER WILL NEED TO PROVIDE
 WHERE THEY HAVE WILL MAKE 20% DISPROPOTIONATE COST OR
 $28,000.00 OVER THE CONTRACT VALUE WILL BE ADDED TO THE
 PROJECT BRINGING THE BUILDING THROUGH A SRIES OF
 RENOVATIONS UP TO THE ACCESSIBILTY CODE. THE MONIES ARE
 TO BE SPENT ON:
 1) AN ACCESSIBLE ENTRANCCE
 2) ACCESSIBLE ROUTE TO ALTERED AREAS
 3) ACCESSIBLE RESTROOMS
  
 NOTE : IF THE FRONT ENTRY WAS 2'-8" CLEAR THE
 RENOVATION OF THE FRONT ENTRY CAN NOT BE USED IN THE
 20% DISPROPORTIONATE COST.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-07-14 Cont ID  
Sent By jwitmer Date 2010-07-14 Time 13:39 Rev Time 0.88
Received By jwitmer Date 2010-07-14 Time 13:39 Sent To  
Notes
2010-07-14 13:41:20BUILDING PLAN REVIEW
 PERMIT: 10070135
 ADD: 425 25TH ST
 CONT: CRL CONSTRUCTION INC
 TEL: (561)248-7177
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) DOORS 2, 5& 6ARE BEING REPLACED ENACTING 2007
 EXISTING BUILDING CODE 706.1 A BUILDING, FACILITY OR
 ELEMENT THAT IS ALTERED SHALL COMPLY WITH CHAPTER 11 OF
 THE FLORIDA BUILDING CODE- BUILDING.
  
 11-4.13.5 CLEAR WIDTH. DOORWAYS SHALL HAVE A MINIMUM
 CLEAR OPENING OF 32 INCHES (813 MM) WITH THE DOOR OPEN
 90 DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND
 THE OPPOSITE STOP [SEE FIGURE 24(A), FIGURE 24(B),
 FIGURE 24(C), AND FIGURE 24(D)]. OPENINGS MORE THAN 24
 INCHES (610 MM) IN DEPTH SHALL COMPLY WITH SECTIONS
 11-4.2.1 AND 11-4.3.3 [SEE FIGURE 24(E)].
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-12-27 Cont ID  
Sent By rlecky Date 2010-12-27 Time 09:14 Rev Time 0.00
Received By rlecky Date 2010-12-27 Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-08-09 Cont ID  
Sent By lmartine Date 2010-08-09 Time 15:15 Rev Time 0.00
Received By lmartine Date 2010-08-09 Time 15:14 Sent To  
Notes
2010-08-09 15:18:01ELECTRICAL REVIEW COMMENTS
  
  
 1. LIGHTING FIXTURES SPEC' S
 2.FBC CHAPTER 13 LIGHTING POWER DENSITIES CALC.
  
  
  
 KIM WATKINS 305-506-7423

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2011-04-18 Cont ID  
Sent By mgonzale Date 2011-04-18 Time   Rev Time 0.50
Received By mgonzale Date 2011-04-18 Time   Sent To  
Notes
2011-04-18 14:32:00PASSED
  
 SEPARATE PERMIT APPLICATION, PLANS AND FEES ARE
 REQUIRED FOR DUMPSTER ENCLOSURE, PARKING, STRIPING,
 ASPHALT. TO BE COMPLETED PRIOR TO C.O. (CERTIFICATE OF
 OCCUPANCY)
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2011-01-12 Cont ID  
Sent By   Date 2011-01-12 Time   Rev Time 1.00
Received By   Date 2011-01-12 Time   Sent To  
Notes
2011-01-12 08:48:33TRASH LOCATION DOES NOT MEET THE REQUIREMENT OF THE
 SANITATION DEPT.
  
 PICKUP IS AVAILABLE THRU THE ALLEY AND NOT 25TH ST.
  
 THE TRASH IS PICK-UP TRUCK RUNS FROM WEST TO EAST.
  
 SUGGEST SETTING UP A MEETING WITH SANITATION TO DISCUSS
 DUMPSTER LOCATION.
  
 TRASH ACCESSABILITY MUST ALSO BE INCLUDED IN THE
 AGREEMENT WITH ACCESSIBLE PROPERTY.
  
 PLEASE CONTACT:
 GREGORY RODGERS
 SANITATION SUPERVISOR
 PUBLIC WORKS DEPARTMENT SANITATION
 1045 CHARLOTTE AVE (COMPLEX)
 WEST PALM BEACH, FL 33401
 PHONE: 822-2075 EXT: 2077
 FAX: 822-2084
 E-MAIL: [email protected]
  
 ******************************
 COMMENTS MADE BY:
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET,
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-07-29 Cont ID  
Sent By mcarsill Date 2010-07-29 Time 09:40 Rev Time 0.00
Received By mcarsill Date 2010-07-29 Time 09:36 Sent To  
Notes
2010-07-29 09:40:48425-25TH STREET
 PERMIT NUMBER 10070135
 ALTERATIONS AND REPAIR
  
  
 1. NOTE ON PAGE A-1 REFERENCES "EXISTING HOUSE". PLANS
 ARE FOR A COMMERCIAL BUILDING.
  
 2. SEPARATE PLANS AND PERMITS REQUIRED FOR THE
 RELOCATION OF THE EXISTING FIRE SUPPRESSION SYSTEM.
 KITCHEN FIRE SUPPRESSION SYSTEM SHALL MEET THE UL 300
 STANDARD FOR KITCHEN FIRE SUPPRESSION SYSTEMS.
  
 3. ALL ELECTRICAL WORK TO COMPLY WITH NFPA 70, THE
 NATIONAL ELECTRIC CODE.
  
 4. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS.
  
 APPROVED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2010-07-27 Cont ID  
Sent By lwagner Date 2010-07-27 Time 08:03 Rev Time 0.00
Received By lwagner Date 2010-07-22 Time 14:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-04-22 Cont ID  
Sent By rbrown Date 2011-04-22 Time 13:16 Rev Time 0.00
Received By jwitmer Date 2011-04-15 Time 19:26 Sent To  
Notes
2011-04-15 19:27:32RESUBMITTED PLANS AND APPLICATION ROUTED TO LINDA MIA
 FRANCO. EXTERIOR WORK WAS REMOVED FROM SCOPE BY
 CONTRACTOR.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-02-15 Cont ID  
Sent By jwitmer Date 2011-02-15 Time 08:28 Rev Time 0.00
Received By jwitmer Date 2011-02-15 Time 08:28 Sent To  
Notes
2011-02-15 08:39:20INCOMING SENT TO C-25 BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-12-29 Cont ID  
Sent By jwitmer Date 2010-12-27 Time 12:55 Rev Time  
Received By lmartine Date 2010-10-13 Time 08:47 Sent To  
Notes
2010-10-14 08:55:56C-21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-08-10 Cont ID  
Sent By hmoser Date 2010-08-10 Time 16:31 Rev Time 0.00
Received By hmoser Date 2010-07-08 Time 08:54 Sent To  
Notes
2010-07-08 08:56:43C-26

Review Stop L LANDSCAPING
Rev No 4 Status N Date 2011-04-22 Cont ID  
Sent By jwitmer Date 2011-04-22 Time 13:15 Rev Time 0.00
Received By jwitmer Date 2011-04-22 Time 13:15 Sent To  
Notes
2011-04-22 13:16:49PLEASE SEE LANDSCAPE PERMIT ISSUED UNDER 10100158. JW

Review Stop L LANDSCAPING
Rev No 3 Status F Date 2011-03-03 Cont ID  
Sent By rkussner Date 2011-03-03 Time 15:05 Rev Time 0.00
Received By rkussner Date 2011-03-03 Time 15:05 Sent To  
Notes
2011-03-03 15:10:13***LANDSCAPE REVIEW OF SITE PLAN FAILED***
  
 HARDSCAPE SHOWN ON APPROVED LANDSCAPE PLAN DOES NOT
 CORRESPOND WITH THIS PROPOSED SITE PLAN. THERE ARE
 PLANTING AREAS WITHIN THE BRICK WALKWAY WITH PROPOSED
 PALM GROUPINGS ON THE LANDCAPE PLAN. THE PLANTING AREAS
 ARE NOT SHOWN ON THIS SITE PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2010-10-15 Cont ID  
Sent By rkussner Date 2010-10-15 Time 16:58 Rev Time 0.00
Received By rkussner Date 2010-10-15 Time 16:58 Sent To  
Notes
2010-10-15 17:00:56***LANDSCAPE REVIEW NOT REQUIRED***
  
 PLEASE REFER TO PERMIT #10100158 FOR LANDSCAPE PERMIT
 AND PLANS.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-08-06 Cont ID  
Sent By rkussner Date 2010-08-06 Time 16:03 Rev Time 0.00
Received By rkussner Date 2010-08-06 Time 16:03 Sent To  
Notes
2010-08-06 16:10:07***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 2. LANDSCAPING REQUIRES A SEPARATE PERMIT. PLEASE APPLY
 FOR A LANDSCAPE PERMIT AND SUBMIT TWO COPIES OF A
 COMPLETE LANDSCAPE PLAN SHOWING COMPLIANCE WITH
 SECTIONS 94-442 AND 94-445 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS. IT SHALL BE SIGNED AND SEALED
 BY A REGISTERED LANDSCAPE ARCHITECT. A CERTIFIED COST
 ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL LANDSCAPE
 MATERIALS AND LABOR. IT SHALL BE BROKEN DOWN INTO UNIT
 COST.
  
 3. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 4. PURSUANT TO SECTION 94-448 (D) (2), THE LANDSCAPE
 PLAN SHALL CONTAIN ALL OF THE ITEMS ENUMERATED IN THIS
 SECTION.
  
 4. AN IRRIGATION PERMIT IS REQUIRED. PLEASE SUBMIT TWO
 (2) COPIES OF AN IRRIGATION PLAN THAT PROVIDES 120%
 COVERAGE TO ALL LANDSCAPED AREAS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-11-16 Cont ID  
Sent By hmoser Date 2010-11-16 Time 10:16 Rev Time 0.00
Received By hmoser Date 2010-11-16 Time 10:15 Sent To  
Notes
2010-11-16 10:28:26PASS PROVISO
 PLEASE REFER TO SECTION 13-409.AB.3.3 FLA.ENERGY CODE
 2007 SHUTOFF DAMPER CONTROLS. BOTH OUTDOOR AIR SUPPLY
 AND EXHAUST SYSTEMS SHALL BE EQUIPPED WITH MOTORIZED
 DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE SYSTEMS
 OR SPACE SERVED ARE NOT IN USE.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-08-10 Cont ID  
Sent By hmoser Date 2010-08-10 Time 15:47 Rev Time 0.00
Received By hmoser Date 2010-08-10 Time 15:47 Sent To  
Notes
2010-08-10 16:11:32PASS PROVISO
 PAGE M-3 KEY NOTES # 3 AND # 4 DO NOT MATCH AIR
 TERMINAL DEVICE SCHEDULE ON PAGE M-5 .PLEASE PROVIDE A
 LETTER AT THE FIRST ROUGH INSPECTION FROM THE ARCHITECT
 ON WHAT SIZE GRILLS ARE TO BE INSTALLED BY THE
 CONTRACTOR
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-07-27 Cont ID  
Sent By lwagner Date 2010-07-27 Time 08:10 Rev Time 0.00
Received By lwagner Date 2010-07-21 Time 14:19 Sent To  
Notes
2010-07-22 15:14:22******PROVISO*******
  
 314.2.1 CONDENSATE DISPOSAL. CONDENSATE FROM ALL
 COOLING COILS AND EVAPORATORS SHALL BE CONVEYED FROM
 THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL.
  
 608.15.4 PROTECTION BY A VACUUM BREAKER. OPENINGS AND
 OUTLETS SHALL BE PROTECTED BY ATMOSPHERIC-TYPE OR
 PRESSURE-TYPE VACUUM BREAKERS. THE CRITICAL LEVEL OF
 THE VACUUM BREAKER SHALL BE SET A MINIMUM OF 6 INCHES
 (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE OR
 DEVICE.
  
 905.4 VERTICAL RISE OF VENT. EVERY DRY VENT SHALL RISE
 VERTICALLY TO A MINIMUM OF 6 INCHES (152 MM) ABOVE THE
 FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE
 BEING VENTED.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2011-04-20 Cont ID  
Sent By lfranco Date 2011-04-20 Time 10:46 Rev Time 4.00
Received By lfranco Date 2011-04-20 Time 10:46 Sent To L
Notes
2011-04-20 10:49:57PLANNING AND ZONING: **** PASSED WITH PROVISO: THIS
 PERMIT IS FOR INTERIOR WORK ONLY. SEPARATE PERMITS ARE
 REQUIRED FOR ALL EXTERIOR WORK (FOR EXAMPLE, PARKING
 STRIPPING, DUMPSTER ENCLOSURE) PRIOR TO C.O. OR
 CERTIFICATE OF COMPLETION C.O.C. ANY OTHER WORK SUCH AS
 SIGNAGE, MURAL WORK REQUIRES ADDITIONAL PERMITS PRIOR
 TO WORK BEING PERFORMED (WHEN THE APPLICANT IS READY TO
 SUBMIT). LMF

Review Stop Z ZONING
Rev No 2 Status F Date 2010-11-10 Cont ID  
Sent By lfranco Date 2010-11-10 Time 19:49 Rev Time 0.00
Received By lfranco Date 2010-11-10 Time 19:49 Sent To  
Notes
2010-11-10 20:08:32PLANNING AND ZONING: *** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE
 REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. THIS PROPERTY IS WITHIN THE NORTHWOOD MIXED USE
 DISTRICT ("NMUD") BUILDING TYPE I, PURSUANT TO THE
 ZONING AND LAND DEVELOPMENT REGULATIONS ("ZLDR")
 SECTION 94-211(A)(2): STORIES AT THE SIDEWALK LEVEL
 SHALL BE NO LESS THAN 12 FEET IN HEIGHT FROM FINISHED
 FLOOR TO FINISHED CEILING AND SHALL NOT EXCEED 16 FEET
 IN HEIGHT FROM FINISHED FLOOR TO FINISHED FLOOR.
 EXISTING FINISHED CEILINGS MAY BE EXEMPT FROM THE
 HEIGHT PROVISION, PROVIDED ANY RENOVATIONS DO NOT
 REQUIRE THE REMOVAL OF ANY OF THE EXTERIOR WALLS,
 CEILINGS OR ROOF. MEZZANINES THAT EXCEED THE
 PERMISSIBLE PERCENTAGE OF FLOOR AREA FOR A MEZZANINE AS
 DEFINED IN THE CITY'S BUILDING CODE SHALL BE COUNTED AS
 A STORY.
  
 PROVIDE THE CEILING HEIGHT FOR ALL AREAS.
  
 4. PURSUANT TO THE ZLDR, SECTION 94-213(D)(5):
 STOREFRONTS ARE REQUIRED ON THE FRONTAGE LINES AND
 SHALL BE DIRECTLY ACCESSIBLE FROM SIDEWALKS.
 STOREFRONTS SHALL PROVIDE CLEAR GLAZED AREAS AS
 FOLLOWS:
  
 A. FOR NEW CONSTRUCTION, EACH STOREFRONT SHALL HAVE
 CLEAR GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF
 ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND
 AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL FRONTAGES.
 B. RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS SHALL NOT REDUCE THE ORIGINAL
 PERCENTAGE OF CLEAR GLAZED AREAS, IF IT IS MORE THAN 50
 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM
 THE GROUND.
 C RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS THAT HAVE CLEAR GLAZED AREAS LESS
 THAN 50 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT
 FEET FROM THE GROUND, MUST PROVIDE AT LEAST 50 PERCENT
 CLEAR GLAZED OF ITS FACADE, BETWEEN TWO AND EIGHT FEET
 FROM THE GROUND.
 D. ADDITIONS ON THE FRONTAGE LINE SHALL HAVE CLEAR
 GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF ITS
 FRONT FACADE, BETWEEN TWO AND EIGHT FEET FROM THE
 GROUND AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL
 FRONTAGES.
  
 PROVIDE ELEVATION OF ALL EXISTING STOREFRONTS WITH THE
 MINIMUM DIMENSIONAL REQUIREMENTS SHOWING GLAZING
 COMPLIANCE. PROVIDE THESE REQUIREMENTS ON A DATA MATRIX
 OF WHAT IS REQUIRED AND PROVIDED FOR GLAZING. INCLUDE
 SQUARE FOOTAGE OF FACADE, ETC. ALSO THE STOREFRONT
 SHALL MEET A MINIMUM OF 70 PERCENT OF GLAZING
 REQUIREMENTS AND SHALL BE DISPERSED THROUGHOUT THE
 FACADE.
  
 RE-SUBMITTAL: THE PROPOSED PERCENTAGE IS UNDER REVIEW,
 WILL AMEND COMMENTS UPON COMPLETION OF REVIEW. THE
 WINDOW ON THE EAST SIDE OF THE ELEVATION DOES NOT GO TO
 THE FULL LEVEL BETWEEN THE 2' FEET AND 8' FEET AREA,
 WASN'T THIS WINDOW GOING TO BE REVISED TO ADD THE
 ADDITIONAL GLAZING REQUIRED?
  
 5. THE PROPOSED PARKING IS BACKING INTO ADJACENT
 PROPERTY, WHICH IS NOT ALLOWED PER ZLDR, SECTION
 94-485(N). IS THERE AN EXISTING RECORDED ACCESS
 AGREEMENT WITH THE ADJACENT PROPERTY OWNER?
  
 RE-SUBMITTAL: A RECORDED ACCESS AGREEMENT IS REQUIRED,
 PRIOR TO THE APPROVAL BY THE PLANNING AND ZONING
 DEPARTMENT.
  
 6. PURSUANT TO SECTION 94-212(16): MECHANICAL SYSTEMS
 SHALL BE SCREENED FROM VIEW BY LANDSCAPING OR BUILT
 ELEMENTS DESIGNED AS AN INTEGRAL PART OF THE BUILDING
 ARCHITECTURE. PROVIDE ELEVATION SHOWING THE MECHANICAL
 LINE WITHIN PARAPET OR SIMILAR STRUCTURE, IF
 APPLICABLE.
  
 RE-SUBMITTAL: MECHANICAL EQUIPMENT IS STILL SHOWING.
 WHERE IS THE EXISTING MECHANICAL EQUIPMENT NOW? IS IT
 IN THE SAME VICINITY?
  
 7. PURSUANT TO SECTION 94-212(17) : DUMPSTERS AND
 STORAGE AREAS SHALL BE ENCLOSED IN THE BUILDING OR
 SHIELDED FROM VIEW BY BUILT ENCLOSURES CONSISTENT WITH
 THE ARCHITECTURE OF THE BUILDING. A SEPARATE PERMIT FOR
 PARKING PAVING AND STRIPPING WITH DUMPSTER ENCLOSURE
 WILL BE REQUIRED.
  
 RE-SUBMITTAL: THE BUILDING IS BLOCK CONCRETE AND THE
 DUMPSTER IS MADE OUT OF WOOD WHICH IS NOT CONSISTENT
 WITH THE PROVISIONS ABOVE. REVISE ACCORDINGLY.
 A SEPARATE PERMIT FOR PAVING AND STRIPPING WITH
 DUMPSTER ENCLOSURE WILL BE REQUIRED.
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-08-05 Cont ID  
Sent By lfranco Date 2010-08-05 Time 20:36 Rev Time 0.00
Received By lfranco Date 2010-08-05 Time 20:36 Sent To L
Notes
2010-08-05 20:44:43PLANNING AND ZONING: *** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE
 REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. THIS PROPERTY IS WITHIN THE NORTHWOOD MIXED USE
 DISTRICT ("NMUD") BUILDING TYPE I, PURSUANT TO THE
 ZONING AND LAND DEVELOPMENT REGULATIONS ("ZLDR")
 SECTION 94-211(A)(2): STORIES AT THE SIDEWALK LEVEL
 SHALL BE NO LESS THAN 12 FEET IN HEIGHT FROM FINISHED
 FLOOR TO FINISHED CEILING AND SHALL NOT EXCEED 16 FEET
 IN HEIGHT FROM FINISHED FLOOR TO FINISHED FLOOR.
 EXISTING FINISHED CEILINGS MAY BE EXEMPT FROM THE
 HEIGHT PROVISION, PROVIDED ANY RENOVATIONS DO NOT
 REQUIRE THE REMOVAL OF ANY OF THE EXTERIOR WALLS,
 CEILINGS OR ROOF. MEZZANINES THAT EXCEED THE
 PERMISSIBLE PERCENTAGE OF FLOOR AREA FOR A MEZZANINE AS
 DEFINED IN THE CITY'S BUILDING CODE SHALL BE COUNTED AS
 A STORY.
  
 PROVIDE THE CEILING HEIGHT FOR ALL AREAS.
  
 4. PURSUANT TO THE ZLDR, SECTION 94-213(D)(5):
 STOREFRONTS ARE REQUIRED ON THE FRONTAGE LINES AND
 SHALL BE DIRECTLY ACCESSIBLE FROM SIDEWALKS.
 STOREFRONTS SHALL PROVIDE CLEAR GLAZED AREAS AS
 FOLLOWS:
  
 A. FOR NEW CONSTRUCTION, EACH STOREFRONT SHALL HAVE
 CLEAR GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF
 ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM THE GROUND
 AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL FRONTAGES.
 B. RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS SHALL NOT REDUCE THE ORIGINAL
 PERCENTAGE OF CLEAR GLAZED AREAS, IF IT IS MORE THAN 50
 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT FEET FROM
 THE GROUND.
 C RENOVATIONS OR ADDITIONS (NOT ON THE FRONTAGE LINE)
 TO EXISTING BUILDINGS THAT HAVE CLEAR GLAZED AREAS LESS
 THAN 50 PERCENT OF ITS FACADE, BETWEEN TWO AND EIGHT
 FEET FROM THE GROUND, MUST PROVIDE AT LEAST 50 PERCENT
 CLEAR GLAZED OF ITS FACADE, BETWEEN TWO AND EIGHT FEET
 FROM THE GROUND.
 D. ADDITIONS ON THE FRONTAGE LINE SHALL HAVE CLEAR
 GLAZED AREAS EQUAL TO A MINIMUM OF 70 PERCENT OF ITS
 FRONT FACADE, BETWEEN TWO AND EIGHT FEET FROM THE
 GROUND AND MUST BE EQUALLY DISPERSED THROUGHOUT ALL
 FRONTAGES.
  
 PROVIDE ELEVATION OF ALL EXISTING STOREFRONTS WITH THE
 MINIMUM DIMENSIONAL REQUIREMENTS SHOWING GLAZING
 COMPLIANCE. PROVIDE THESE REQUIREMENTS ON A DATA MATRIX
 OF WHAT IS REQUIRED AND PROVIDED FOR GLAZING. INCLUDE
 SQUARE FOOTAGE OF FACADE, ETC. THE IMPROVEMENTS SHALL
 INCLUDE THE SIDE ELEVATIONS TO THE EAST, AND NO
 REDUCTION OF THE GLAZING WILL BE ALLOWED.
 SHEET A-1 SHOWS OPENING PROPOSED TO BE ENCLOSED, NO
 REDUCTION OF EXISTING GLAZING WILL BE ALLOWED. ALSO THE
 STOREFRONT SHALL MEET A MINIMUM OF 70 PERCENT OF
 GLAZING REQUIREMENTS AND SHALL BE DISPERSED THROUGHOUT
 THE FACADE. THE CURRENT ELEVATION SHOWS THE EAST SIDE
 OF THE FACADE TO BE ENCLOSED (EXISTING FACADE HAD
 GLAZING IN THIS AREA). THE GLAZING IS NOT EQUALLY
 DISPERSED.
  
 5. THE PROPOSED PARKING IS BACKING INTO ADJACENT
 PROPERTY, WHICH IS NOT ALLOWED PER ZLDR, SECTION
 94-485(N). IS THERE AN EXISTING RECORDED ACCESS
 AGREEMENT WITH THE ADJACENT PROPERTY OWNER?
  
 6. PURSUANT TO SECTION 94-212(16): MECHANICAL SYSTEMS
 SHALL BE SCREENED FROM VIEW BY LANDSCAPING OR BUILT
 ELEMENTS DESIGNED AS AN INTEGRAL PART OF THE BUILDING
 ARCHITECTURE. PROVIDE ELEVATION SHOWING THE MECHANICAL
 LINE WITHIN PARAPET OR SIMILAR STRUCTURE, IF
 APPLICABLE.
  
 7. PURSUANT TO SECTION 94-212(17) : DUMPSTERS AND
 STORAGE AREAS SHALL BE ENCLOSED IN THE BUILDING OR
 SHIELDED FROM VIEW BY BUILT ENCLOSURES CONSISTENT WITH
 THE ARCHITECTURE OF THE BUILDING.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  