Plan Review Stops For Permit 10060862 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-03-01 |
Time |
08:50 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2011-03-01 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-07-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-07-15 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-07-15 |
Time |
14:06 |
Sent To |
|
|
Notes |
2010-07-15 14:07:28 | BUILDING REVIEW CHECKLIST. | | 2007 FBC WITH 2009 REVISIONS. | | | | 1- PERMIT APPLICATION SUBMITTED IS FOR MECHANICAL AND | | ELECTRICAL PERMITS ONLY. QUALIFIED CONTRACTOR NEEDS TO | | APPLY FOR THE BUILDING PERMIT FOR THE CONSTRUCTION OF | | THE COUNTERTOP BY THE TAKE OUT AREA. UPDATE VALUATION | | TO INCLUDE THE SCOPE OF WORK TO BE DONE BY THE GENERAL | | CONTRACTOR AND THE DESIGN PROFESSIONAL FEES AS REQUIRED | | BY SEC. 108.3 OF CITY AMENDMENTS TO FBC. | | | | 2- DRAWING C1: | | A) REVISE CODE ANALYSIS INFORMATION. | | (1) OCCUPANCY CLASSIFICATION IS NOT BUSINESS. SEE | | CHAPTER 3 OF 2007 FBC AND REVISE AS REQUIRED. | | (2) REVISE CONSTRUCTION TYPE. THIS BUILDING IS NOT | | TIMBER CONSTRUCTION. REVISE AS REQUIRED. | | (3) REVISE TOTAL OCCUPANT LOAD SPECIFIED TO INCLUDE THE | | EXISTING RETAIL AREA.. SEE TABLE 1004.1.1 AND REVISE AS | | REQUIRED. | | | | B) REVISE THE MINIMUM INTERIOR FINISH CLASSIFICATION | | TABLE AT THE BOTTOM OF THE GENERAL NOTES COLUMN ON THE | | LEFT BOTTOM OF THE PAGE TO MATCH SPECIFIED OCCUPANCY | | CLASSIFICATION. THIS IS NOT ASSEMBLY TYPE. COORDINATE | | WITH ITEM 2(A)(1) ABOVE. | | | | 3- DRAWING A-1: A) SPECIFY ALL DIMENSIONS BY THE TAKE | | OUT COUNTER AREA TO VERIFY COMPLIANCE WITH THE | | ACCESSIBILITY REQUIREMENTS OF CHAPTER 11 OF 2007 FBC. | | SHOW THE WHEELCHAIR TURNING SPACE IN FRONT OF DISPLAY | | CABINET AND COUNTERTOP AREA AS REQUIRED BY SEC. | | 11-4.2.3 OF 2007 FBC. | | | | B) WALL SHOWN BY EXISTING OFFICE IS NOT SHOWN ON THE | | WALL LEGEND. CLARIFY IF NEW WALL. CHECK WITH CHAPTER 11 | | DOOR MANEUVERING REQUIREMENTS. | | | | 4- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | BY SEC. 713.13 FLORIDA STATUTE. | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | UP. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-07-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-07-14 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-07-14 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2011-05-03 |
|
|
Cont ID |
|
Sent By |
ddaniels |
Date |
2011-05-03 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
ddaniels |
Date |
2011-05-03 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-07-26 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2010-07-26 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2010-07-26 |
Time |
13:48 |
Sent To |
|
|
Notes |
2010-07-26 14:01:07 | PERMIT APPLICATION INDICATES HOOD INSTALL, WI FREEZER | | PERMIT NUMBER 10060862 | | | | | | 1. CONSTRUCTION, DEMOLITIION, AND RENOVATION TO COMPLY | | WITH NFPA 241. | | | | 2. SEPARATE PLANS AND PERMITS REQUIRED FOR THE | | INSTALLATION OF A HOOD,DUCT, AND FIRE SUPPRESSION | | SYSTEM. | | | | 3. DOES THE AREA INDICATED AS A NO WORK ON THIS AREA | | EQUIPPPED WITH ANY ILLUMINATED EXIT SIGNS OR EMERGENCY | | LIGHTING EQUIPMENT. | | | | 4. GAS INSTALLATION TO COMPLY WITH NFPA 54. | | | | 5. SOME DISCREPANCIES EXIST ON THE PLANS AS IDENTIFIED | | BY THE BUILDING PLANS EXAMINER. | | | | 6. SEPARATE PLAMS AND PERMITS REQUIRED FOR THE HOOD | | FIRE SUPPRESSION SYSTEM PLANNED FOR THE HOOD. | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | BUREAU OF FIRE PREVENTION |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2010-07-12 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-07-12 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-07-12 |
Time |
14:01 |
Sent To |
|
|
Notes |
2010-07-12 14:35:06 | GAS PERMIT REQUIRED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-07-26 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-07-26 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-07-01 |
Time |
09:53 |
Sent To |
|
|
Notes |
2010-07-14 11:38:28 | C-19./WRT. | 2010-07-06 16:00:42 | PUT IN PLUMBING BOX | 2010-07-01 09:53:37 | IN MECHANICAL BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-07-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-07-06 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-07-06 |
Time |
09:54 |
Sent To |
|
|
Notes |
2010-07-06 11:33:20 | PROVISO | | PLEASE PROVIDE A LETTER FROM THE ENGINEER ON THE STAND | | TIE DOWN TO THE ROOF , FOR THE ROUGH INSPECTION | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-07-12 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-07-12 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-07-12 |
Time |
14:35 |
Sent To |
E |
|
Notes |
2010-07-12 14:47:17 | PLUMBING PERMIT REQUIRED | | SUBMIT GREASE TRAP AT 1ST INSPECTION |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2011-03-03 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-03-03 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-03-03 |
Time |
17:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-07-21 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-07-21 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-07-21 |
Time |
11:31 |
Sent To |
|
|
Notes |
2010-07-21 13:34:45 | ***FAILED*** | | | | 1. SHEET A-1, FLOOR PLAN, SHOWS A DOOR TO BE CLOSED. | | PLEASE PROVIDE DETAILS. NOTE THAT SECTION 94-221(D)(5) | | OF THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS | | REQUIRES A MINIMUM OF 70 PERCENT OF THE FACADE OF THE | | BUILDING BETWEEN 2 AND 8 FEET TO BE CLEAR GLAZED. | | ALTHOUGH THE STRUCTURE IS BELOW THE REQUIRED 70 | | PERCENT, YOU MAY GO NO LOWER THAN WHAT IS PROVIDED | | TODAY. IF THERE IS GLAZING INCORPORATED INTO THE DOOR | | TO BE REMOVED, AN AMOUNT OF GLAZING EQUAL OR GREATER | | THAN THAT IN THE DOOR MUST BE PROVIDED. | | | | 2. SECTION 94-221(D)(8) REQUIRES THAT MECHANICAL | | SYSTEMS BE SCREENED FROM VIEW ON ALL SIDES TO THE FULL | | HEIGHT OF THE EQUIPMENT BY BUILT ELEMENTS. | | | | PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT | | 561-822-1458 OR [email protected] WITH QUESTIONS. |
|
|