Plan Review Details - Permit 10060663
Plan Review Stops For Permit 10060663 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-07-23 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-07-23 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-07-23 |
Time |
10:58 |
Sent To |
|
|
Notes |
2010-07-23 10:58:39 | *****APPROVED***** | | | | MIKE CARSILLO, BATTALION CHIEF | | & WESLEY JOLIN | | FIRE PLAN REVIEW | | 561-805-6730 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2010-06-28 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-06-28 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-06-28 |
Time |
10:32 |
Sent To |
|
|
Notes |
2010-06-28 12:35:32 | *****DENIED***** | | | | 1) SOUTHWEST AREA OF GRILL #109 DOES NOT HAVE SPRINKLER | | COVERAGE. CLOSEST SPRINKLER IS LOCATED ON OPPOSITE SIDE | | OF WALL. | | | | 2) ROOM LABELED COMFORT #108 NEAR COLUMN INTERSECTION | | 10/G FEATURES A WALL WITH AN ELECTRICAL PANEL. THE | | SPRINKLER IS LOCATED 10'-0" FROM THE WALL. | | | | 3) ARCHITECTURAL CEILING DETAIL FOR COMFORT #108 INFERS | | CEILING DOES NOT ENCLOSE THE ENTIRE ROOM. VERIFY | | CEILING IS NOT OPEN TO STRUCTURE ABOVE FLOATING SLOPED | | CLOUDS. IF CEILING HAS OPENINGS, PROVIDE SPRINKLER | | PROTECTION ABOVE CEILING. | | | | 4) THE 11'-0" RECTANGULAR CEILING WITH AN OVAL INTERIOR | | CEILING OF 9'-1" AND 8'-0" ONLY PROVIDES SPRINKLER | | PROTECTION FOR THE 9'-1" CEILING. THE FLOOR AREA BELOW | | THE 11'-0" AND 8'-0" CEILINGS ARE UNPROTECTED. | | ADDITIONAL SPRINKLERS MAY REQUIRE A SEPARATE BRANCH | | LINE TO AVOID OVER TAXING THE EXISTING BRANCH LINES. | | | | 5) PROVIDE NOTE ON THE DRAWING STATING AREAS OF EXPOSED | | STRUCTURE ARE CONSIDERED OBSTRUCTED CONSTRUCTION OR | | UNOBSTRUCTED CONSTRUCTION. | | | | | | CAPT. MICHAEL A. WILLIAMS | | & WESLEY JOLIN | | FIRE PLAN REVIEW | | 561-805-6730 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-07-13 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-07-13 |
Time |
08:56 |
Sent To |
|
|
Notes |
2010-07-13 08:56:19 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-06-28 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-23 |
Time |
10:43 |
Sent To |
|
|
Notes |
2010-06-23 10:43:30 | IN FIRE BOX |
|
|
|