Plan Review Details - Permit 10060598
Plan Review Stops For Permit 10060598 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2010-08-18 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-08-18 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-07-23 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-07-23 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-08-18 |
Time |
13:50 |
Sent To |
P |
|
Notes |
2010-07-23 08:33:48 | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} SUBMIT A SITE PLAN AND LOCATE ALL THE SERVICE AND | | GENERATOR GEAR ON SAME SO THAT COMPLIANCE WITH | | 230.72(GROUPING), 225.31-39 FOR THE DISCONNECTING MEANS | | REQUIREMENTS AND 250.32 FOR GROUNDING CAN BE REVIEWED. | | | | 2} 702.5 CAPACITY AND RATING. AN OPTIONAL STANDBY | | SYSTEM SHALL HAVE ADEQUATE CAPACITY AND RATING FOR THE | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE OPERATED AT ONE | | TIME.THE LOAD CALC'S ARE AT 70 AMPS, THE GENERATOR IS | | RATED FOR 65 AMPS. CORRECT THE LOADS. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2010-08-18 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-08-18 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-08-18 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2010-07-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-07-27 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-07-27 |
Time |
11:44 |
Sent To |
|
|
Notes |
2010-07-27 11:46:53 | FBC GAS REVIEW | | DENIED: | | | | 1. LOCATIONS FOR TANK AND GENERATOR HAVE NOT BEEN | | APPROVED BY ZONING. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-08-04 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-08-04 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-08-04 |
Time |
18:03 |
Sent To |
|
|
Notes |
2010-08-04 18:05:36 | IN ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-07-27 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-07-27 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-06-21 |
Time |
11:27 |
Sent To |
|
|
Notes |
2010-06-22 11:27:27 | IN ZONING BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2010-08-16 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-08-13 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-08-06 |
Time |
15:28 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2010-07-14 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-07-14 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-07-14 |
Time |
09:45 |
Sent To |
B |
|
Notes |
2010-07-15 09:24:11 | PLANNING AND ZONING: **** FAILED - COMMENTS NOT | | ADDRESSED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED MECHANICAL | | EQUIPMENT (GENERATOR AND LP TANK) TO ALL PROPERTY | | LINES. AS PER SECTION 94-305(B)(4) OF THE ZONING CODE | | ("ZLDR"): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | THAN 4 FEET INTO A REQUIRED SETBACK. SHOW GENERATOR TO | | SCALE ON SURVEY AND/OR A SCALED SITE PLAN. CLEARLY SHOW | | DIMENSIONS ON SURVEY. ALTHOUGH LP TANK WILL BE | | UNDERGROUND, THE SETBACKS AND ENCROACHMENT ALLOWANCE | | STILL APPLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT, | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-07-01 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-07-01 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-06-23 |
Time |
11:11 |
Sent To |
B |
|
Notes |
2010-07-01 18:46:33 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES. AS PER SECTION | | 94-305(B)(4) OF THE ZONING CODE ("ZLDR"): MECHANICAL | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | REQUIRED SETBACK. SHOW GENERATOR TO SCALE ON SURVEY | | AND/OR A SCALED SITE PLAN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT, | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | |
|
|
|