Plan Review Details - Permit 10060578
Plan Review Stops For Permit 10060578
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-08-19 Cont ID  
Sent By rmcdouga Date 2010-08-19 Time 13:35 Rev Time 0.00
Received By rmcdouga Date 2010-08-19 Time 13:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-08-09 Cont ID  
Sent By rmcdouga Date 2010-08-09 Time 16:13 Rev Time 0.00
Received By rmcdouga Date 2010-08-09 Time 16:13 Sent To  
Notes
2010-08-09 16:13:512007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE INSTALLATION SCHEDULE FOR THE STORM PANELS
 INDICATE THAT THE H-HEADER AT THE TOP IS TO BE ANCHORED
 TO BLOCK. THE PRODUCT APPROVAL REQUIRES POURED CONCRETE
 FOR THIS INSTALLATION. SEE SHEET 2 OF 9 AND THE TABLE
 ON SHEET 5 OF 9. PLEASE CORRECT.
  
 2) PROVIDE A DETAIL OF THE COLUMN CAP AT THE TOP OF THE
 NEW ALUMINUM COLUMN ON THE PLAN.
  
 3) SPECIFY THE CONNECTORS THAT WILL BE USED TO ANCHOR
 THE RAFTERS AT THE LAUNDRY ROOM AND PORCH.
  
 4) SPECIFY THE EXTERIOR WALL COVERING THAT WILL BE USED
 ON THE LAUNDRY ROOM ON THE PLANS. SHOW COMPLIANCE WITH
 FBC R319 FOR CLEARANCE TO GROUND AND FBC R704.1 FOR
 CLEARANCE FOR TERMITE INSPECTION.
  
 5) THE STRUCTURE IS LOCATED IN A 140 MPH WIND SPEED AND
 EXPOSURE CATEGORY C. SPECIFY THE WIND SPEED AND
 EXPOSURE CATEGORY ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-08-24 Cont ID  
Sent By jleahy Date 2010-08-24 Time 14:47 Rev Time 0.00
Received By jleahy Date 2010-08-24 Time 14:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-07-29 Cont ID  
Sent By rmcdouga Date 2010-07-29 Time 15:58 Rev Time 0.00
Received By rmcdouga Date 2010-07-29 Time 15:58 Sent To  
Notes
2010-07-29 16:43:192008 NEC
  
 DENIED BY ELECTRICAL
  
 1) PROVIDE A PANEL SCHEDULE FOR THE NEW SERVICE PANEL.
  
 2) SHOW ALL EXISTING AND NEW ELECTRICAL OUTLETS,
 SWITCHES AND DEVICES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-08-16 Cont ID  
Sent By lmartine Date 2010-08-16 Time 09:06 Rev Time 0.00
Received By lmartine Date 2010-08-16 Time 09:06 Sent To  
Notes
2010-08-16 09:07:28GAVE TO MCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-08-09 Cont ID  
Sent By rmcdouga Date 2010-08-09 Time 16:14 Rev Time 0.00
Received By rmcdouga Date 2010-06-21 Time 11:43 Sent To  
Notes
2010-07-28 17:24:28****************EXPEDITED*****************
 R--9 DHCD JOB
  
2010-06-22 11:44:09IN ZONING BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-08-19 Cont ID  
Sent By rmcdouga Date 2010-08-19 Time 12:02 Rev Time 0.00
Received By rmcdouga Date 2010-08-19 Time 12:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-07-29 Cont ID  
Sent By rmcdouga Date 2010-07-29 Time 16:43 Rev Time 0.00
Received By rmcdouga Date 2010-07-29 Time 16:43 Sent To  
Notes
2010-07-29 16:57:442007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) THE MECHANICAL PLANS ARE REQUIRED TO BE DESIGNED BY
 AN ARCHITECT, ENGINEER OR THE LICENSED HVAC CONTRACTOR
 THAT WILL BE DOING THE INSTALLATION. INDICATE THE NAME
 AND LICENSE NUMBER OF THE DESIGNER ON THE PLANS. FS
 471, 481, 489
  
 2) THE 10 X 10 RETURN FOR MASTER BEDROOM IS TOO SMALL.
 FBC M1602.4
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-07-29 Cont ID  
Sent By rmcdouga Date 2010-07-29 Time 16:43 Rev Time 0.00
Received By rmcdouga Date 2010-07-29 Time 16:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2010-07-03 Cont ID  
Sent By astelly Date 2010-07-03 Time 16:44 Rev Time 0.00
Received By astelly Date 2010-07-03 Time 16:49 Sent To B
Notes
***NONE***