Plan Review Stops For Permit 10060240 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-08-26 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-08-26 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-08-26 |
Time |
14:31 |
Sent To |
|
|
Notes |
2010-08-26 14:32:18 | OK TO PASS PER JWITMER. CONTRACTOR SUBMITTED | | APPLICATION. RJR |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-07-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-07-22 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-07-22 |
Time |
16:39 |
Sent To |
|
|
Notes |
2010-07-22 16:40:15 | 2ND REVIEW: PLANS ARE STAMPED CODE COMPLIANT FOR | | BUILDING, WILL NEED TO VERIFY LICNSURE OF CONTRACTOR, | | CURRENTLY TO BE DETRERMINED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-06-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-06-14 |
Time |
15:03 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2010-06-14 |
Time |
15:03 |
Sent To |
|
|
Notes |
2010-06-14 15:04:34 | PLANS ARE STAMPED CODE COMPLIANT FOR BUILDING, WILL | | NEED TO VERIFY LICNSURE OF CONTRACTOR, CURRENTLY TO BE | | DETRERMINED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-08-17 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2010-08-17 |
Time |
06:43 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2010-08-17 |
Time |
06:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-06-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-06-22 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-06-22 |
Time |
12:18 |
Sent To |
|
|
Notes |
2010-06-22 13:33:13 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008 | | NEC, 2004 FBC AS AMENDED, CHAPTER 1AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE SECTION 13-415.2.ABC.1. AND 13-415.2.C | | REFERENCED ON SHEET E-9 ARE FROM THE 2004 BUILDING CODE | | SEE ABOVE REFERENCED CODES FOR THE CURRENTLY ADOPTED | | CODES. | | | | 2} 4.1 WATTS PER SQ/FT SHOWN IN THE "LUMINARY | | SCHEDULE", SHEET E-9 IS MUCH HIGHER THAN THE ALLOWED | | WATTAGES IN TABLE 13-415.B.1, 2007 FBC. | | | | 3} THE 2005 NEC IS REFERENCED ON SHEET E-9 ALSO 220.20, | | 220.11, 220.13, 220.15ON THE PANEL SCHEDULES ARE NOT | | ARTICLES IN THE 2008 NEC. | | | | 4}PANEL 7LC CURCUITS #2, 4, 15 AND 22 HAVE # 12 | | CONDUCTORS ON A 25 AMP OVERCURRENT DEVICE IN VIOLATION | | OF TABLE 310.16 AND 240.2(D) NEC. | | | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2010-06-25 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-06-25 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-06-25 |
Time |
14:21 |
Sent To |
|
|
Notes |
2010-06-25 14:36:10 | *****APPROVED***** | | | | | | APPROPRIATE PLAN SHEETS A-, A-2, A-3, E-4, AND E-11 | | WERE STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-07-14 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-07-14 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-07-14 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2010-06-30 |
Time |
|
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-09 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2010-06-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-06-14 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-06-14 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2010-08-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2010-08-10 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2010-08-10 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2010-06-30 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-06-30 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-06-29 |
Time |
16:35 |
Sent To |
|
|
Notes |
2010-06-30 11:38:18 | REVIEW #: 1ST | | ACTION: DENIED | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. THE OVERALL SCOPE OF MECHANICAL WORK IS NOT CLEAR | | DUE TO THE MECHANICAL LEGEND. IT USES THE SAME WEIGHT | | LINE TO IDENTIFY BOTH NEW DUCT AND DUCT TO BE REMOVED. | | ALSO, THE SYMBOL FOR A FIRE DAMPER IS NOT THE SAME AS | | THE ONE USED ON THE FLOOR PLAN. ADDITIONALLY, THE | | SYMBOL FOR NEW DUCT TO BE ATTACHED TO EXISTING DUCT IS | | NOT USED ON FLOOR PLAN, EVEN THOUGH THIS CONDITION | | APPEARS TO OCCUR AT SEVERAL LOCATIONS. LASTLY, THE | | SYMBOLS FOR SUPPLY AND RETURN GRILLS APPEAR TO BE | | REVERSED FROM WHAT IS SHOWN ON THE FLOOR PLANS. PLEASE | | COORDINATE SYMBOL LEGEND AND FLOOR PLANS TO CLEARLY | | IDENTIFY THE SCOPE OF WORK PROPOSED AND FACILITATE A | | THOROUGH REVIEW PER FBC-B 106.1.1. | | | | 2. PAGE M-2 SHOWS A MOVINCOOL CM 25 CEILING MOUNTED | | PACKAGE UNIT ABOVE THE SERVER ROOM. PLAN ALSO SHOW A | | 12" ROUND CONDENSER EXHAUST DUCT DISCHARGING INTO THE | | RETURN AIR PLENUM. EXHAUST AIR SHALL BE DISCHARGED | | OUTDOORS TO A LOCATION FROM WHICH IT CANNOT AGAIN BE | | READILY DRAWN IN BY A VENTILATING SYSTEM IN ACCORDANCE | | WITH FBC-M 501.2. ALSO, EXHAUST DUCTS UNDER POSITIVE | | PRESSURE SHALL NOT BE LOCATED WITHIN A PLENUM IN | | ACCORDANCE WITH FBC-M 601.5. | | | | 3. THE OPERATION MANUAL FOR THE CM 25 CALLS FOR A 1/2" | | DRAIN LINE. CONDENSATE WASTE AND DRAIN LINE SIZE SHALL | | BE NOT LESS THAN 3/4 INCH (19 MM) INTERNAL DIAMETER IN | | ACCORDANCE WITH FBC-M 307.2.2. ALSO, ENSURE | | NONCOMBUSTIBLE OR PLENUM RATED MATERIALS ARE USED FOR | | CONDENSATE DRAIN AND CONTROL/POWER WIRING IN ACCORDANCE | | WITH FBC-M 602.2.1. | | | | 4. THE OPERATION MANUAL FOR THE CM 25 INDICATES THAT | | THE DRAIN LINE FROM THE UNIT IS NOT TO BE TRAPPED. | | HOWEVER, NOTE ON PAGE P-1 CALLS FOR 1 1/4" CD TRAP. | | CONDENSATE DRAINS SHALL BE TRAPPED AS REQUIRED BY THE | | EQUIPMENT OR APPLIANCE MANUFACTURER PER FBC-M 307.2.4. | | | | 5. SHOW A MEANS OF AUXILIARY OR SECONDARY DRAIN | | PROTECTION FOR THE CM 25 IN ACCORDANCE WITH FBC-M | | 307.2.3. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-08-26 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-08-26 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-07-21 |
Time |
10:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-06-22 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-06-22 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-06-21 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2010-06-10 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-06-10 |
Time |
19:12 |
Rev Time |
0.25 |
Received By |
lfranco |
Date |
2010-06-10 |
Time |
19:12 |
Sent To |
E |
|
Notes |
2010-06-10 19:13:15 | PLANNING AND ZONING: **** PASSED, *ZONING REVIEW NOT | | REQUIRED: INTERIOR WORK ONLY AND THE VALUE OF PROPOSED | | WORK DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|