Plan Review Details - Permit 10060022
Plan Review Stops For Permit 10060022
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-07-29 Cont ID  
Sent By jgomez Date 2010-07-29 Time 13:14 Rev Time 0.00
Received By jgomez Date 2010-07-29 Time 13:13 Sent To  
Notes
2010-07-29 13:14:44BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- COOKING EQUIPMENT IN LOGGIA: PROVIDE MANUFACTURER
 SPECIFICATIONS SHOWING THAT EQUIPMENT WAS DESIGNED TO
 BE INSTALLED IN THE PROPOSED LOGGIA. LOOK AT THE
 OUTDOOR-COOKING SPECIFICATIONS PROVIDED. IT SAYS "DO
 NOT INSTALL UNDER OVERHEAD, UNPROTECTED COMBUSTIBLE
 CONSTRUCTION AND DO NOT INSTALL ON BREEZEWAYS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-06-24 Cont ID  
Sent By jgomez Date 2010-06-24 Time 13:25 Rev Time 0.00
Received By jgomez Date 2010-06-24 Time 13:25 Sent To  
Notes
2010-06-24 13:36:48RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- ROOF SHEATHING UPLIFT AND ROOF-TO-WALL UPLIFT LOADS
 SHALL BE INCREASED BY 20 PERCENT AS REQUIRED BY SEC.
 R301.2.1.4.3(2). REVISE STRUCTURAL DRAWINGS AS REQUIRED
 TO COMPLY WITH THIS SECTION.
  
 3- SPECIFY THE DESIGN PRESSURES CALCULATED FOR THE
 DOORS AND WINDOWS TO VERIFY COMPLIANCE WITH SEC. R301.
  
 4- PROVIDE MANUFACTURER'S SPECIFICATIONS FOR ALL
 COOKING EQUIPMENT SHOWING THAT THE EQUIPMENT WAS
 DESIGNED TO BE INSTALLED ON THE PORCH A SHOWN ON PLANS.
  
 5- PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR NEW
 FIREPLACE TO BE INSTALLED ON THE NEW PAVILION TO SHOW
 COMPLIANCE WITH CHAPTER 10 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 6- TIMBER STRUCTURAL DRAWINGS AND CALCULATIONS
 SUBMITTED:
 A) REVISE DESIGN CRITERIA TO COMPLY WITH THE 20%
 INCREASED LOADS AS REQUIRED BY SEC. R301.2.1.4.3(2).
 SEE ITEM # 2 ABOVE.
  
 B) REVISE DESIGN CRITERIA. EXPOSURE "D" IS NOT
 APPLICABLE IN FLORIDA. SEE SEC. R301.2.1.4.3(3).
  
 C) ENGINEER (THOMAS R. BEAUDETTE) NEED TO USE CURRENT
 FLORIDA ENGINEER'S SEAL. ENGINEER'S SEAL NEED TO SAY
 "LICENSE" NOT "CERTIFICATE. THE SEAL WAS TO BE UTILIZED
 PRIOR TO JANUARY 1, 2002. SEE SEC. 61G15-23.001 OF
 FLORIDA ADMINISTRATIVE CODE AND SEC. 471.025 OF FLORIDA
 STATUTE.
  
 D) ENGINEER OF RECORD (ALBERT A. GARGIULO) TO REVIEW
 AND APPROVE ALL TIMBER DRAWINGS PRIOR TO SUBMITTAL TO
 THIS OFFICE.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) WINDOW MULLIONS AS SHOWN ON PLANS. AND CLEARLY
 SPECIFY MULLION SIZE AND FASTENERS TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES REQUIRED BY SEC. R301.
  
 B) GLASS BLOCK AS SHOWN ON PLANS.
  
 C) PRECAST LINTELS AS SHOWN ON PLANS.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC.
  
 9- OWES $19.74 FOR RADON FEES AND LANDSCAPE REVIEW FEE.
  
 10- SHEET A-2: REVISE TOP OF CHIMNEY CAP ELEVATION
 SHOWN ON PARTIAL SOUTH ELEVATION. IT CAN'T BE 8'-2".
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-08-11 Cont ID  
Sent By jleahy Date 2010-08-11 Time 07:02 Rev Time 0.00
Received By jleahy Date 2010-08-10 Time 07:03 Sent To  
Notes
2010-08-11 07:03:09GROUNDING AT SEPARATE BUILDING NOT PER CODE, SEE 250.32
 A,B,D JL

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-06-02 Cont ID  
Sent By btrobaug Date 2010-06-02 Time 13:45 Rev Time 0.00
Received By btrobaug Date 2010-06-02 Time 12:45 Sent To  
Notes
2010-06-02 13:45:06 
 REVISION REQUIRED
  
 A DISCONNECT IS REQUIRED AT SEPARATE STRUCTURES PER
 225.31 & 225.32. GROUNDING ELECTRODE PER 250.32, LOCATE
 AND SIZE ON PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2010-08-10 Cont ID  
Sent By dlauderm Date 2010-08-10 Time 14:18 Rev Time 2.00
Received By dlauderm Date 2010-08-10 Time 14:18 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2010-08-09 Cont ID  
Sent By dlauderm Date 2010-08-09 Time 11:02 Rev Time 2.00
Received By dlauderm Date 2010-08-09 Time 11:02 Sent To  
Notes
2010-08-09 11:15:25PLAN REVIEWER: DEAN LAUDERMILK, PROJECT COORDINATOR
 PHONE: 494-1083
 FAX: 494-1116
 EMAIL: [email protected]
 PLAN STATUS: FAILED
 1. THE PLAN HAS BEEN TURNED DOWN FOR THE REASONS LISTED
 BELOW. IT IS SUGGESTED THAT THE OWNER MEET WITH THE
 UTILITY OWNERS WHO ARE LOCATED IN THE EASEMENT TO SEE
 IF THE EASEMENT CAN BE REDUCED IN SIZE.
 IF ALLOWED, THEN THERE IS A FORM ON OUR WEB PAGE THAT
 WILL NEED TO BE FILLED OUT AND SUBMITTED TO PLANNING.
 OUR WEB PAGE ADDRESS IS;
 HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP AND THE
 FORM NAME IS "APPLICATION FOR ABANDONMENT OF EASEMENT".
 THE CITY OF WEST PALM BEACH DOES NOT USE THIS EASEMENT
 AND AS SUCH WILL NOT APPOSE REDUCING THE EASEMENT SIZE.
 A. NO STRUCTURES CAN BE BUILT IN OR OVER A UTILITY
 EASEMENT, AS OUTLINED IN THE PLAT.
 B. THE PLAN IS FAILED UNTIL THE EASEMENT IS REDUCED IN
 SIZE OR THE PLAN IS RESUBMITTED WITH ALL IMPROVEMENTS
 OUTSIDE OF THE EASEMENT, INCLUDING FOOTERS, WALLS, AND
 OVERHANGS.
 2. ADDITIONALLY TWO OF THE UTILITIES DID NOT CIRCLE
 "APPROVED" ON THEIR FORMS. THE ATT AND COMCAST FORMS
 NEED TO BE RESUBMITTED IF USED.
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2010-07-29 Cont ID  
Sent By jgomez Date 2010-07-29 Time 13:13 Rev Time 0.00
Received By jgomez Date 2010-07-29 Time 13:13 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2010-06-23 Cont ID  
Sent By jgomez Date 2010-06-23 Time 14:19 Rev Time 0.00
Received By jgomez Date 2010-06-23 Time 14:19 Sent To  
Notes
2010-06-23 14:25:16RESIDENTIAL (R3) ADDITION, GAS REVIEW.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- REVISE GAS NOTES. UNDERGROUND PIPING NEED TO COMPLY
 WITH SEC. G2418.8. NEED PLASTIC PIPING.
  
 2- NEED SEPARATE PERMIT FOR GAS WORK.
  
 3- PROVIDE ALL THE INFORMATION ON SHEET P-1 AS REQUIRED
 BY THE CITY GAS PERMIT APPLICATION REQUIREMENTS. SEE
 ATTACHED COPY.
 ***NOTE: INFORMATION MAY BE SUBMITTED BY THE GAS
 CONTRACTOR AT TIME OF GAS PERMIT APPLICATION.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-07-22 Cont ID  
Sent By jgomez Date 2010-07-22 Time 08:47 Rev Time 0.00
Received By jgomez Date 2010-07-22 Time 08:40 Sent To  
Notes
2010-07-22 08:47:57SENT TO R19.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-24 Cont ID  
Sent By jgomez Date 2010-06-24 Time 13:36 Rev Time 0.00
Received By jgomez Date 2010-06-01 Time 13:20 Sent To  
Notes
2010-06-01 13:24:14R-26

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2010-06-23 Cont ID  
Sent By jgomez Date 2010-06-23 Time 14:16 Rev Time 0.00
Received By jgomez Date 2010-06-23 Time 14:16 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 3 Status N Date 2010-07-28 Cont ID  
Sent By rkussner Date 2010-07-28 Time 15:58 Rev Time 0.00
Received By rkussner Date 2010-07-28 Time 15:58 Sent To  
Notes
2010-07-28 16:00:24***LANDSCAPE NOT REQUIRED***
  
 LANDSCAPING IS UNDER SEPARATER PERMIT #10070731.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2010-07-26 Cont ID  
Sent By rkussner Date 2010-07-26 Time 16:18 Rev Time 0.00
Received By rkussner Date 2010-07-26 Time 16:18 Sent To  
Notes
2010-07-26 16:24:42***LANDSCAPE REVIEW FAILED***
  
 RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. REPEAT COMMENT: PURSUANT TO SECTION 94-441(C)(2) OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR): AS
 THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE
 STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH
 THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING
 SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS
 FOUND IN ARTICLE XIV OF THE ZLDR. THE LANDSCAPE PLAN
 SHALL IDENTIFY ALL NEW AND EXISTING TREES, PLANTS AND
 GROUND COVER FOR THE ENTIRE SITE.
  
 2. REPEAT COMMENT: LANDSCAPING REQUIRES A SEPARATE
 PERMIT. PLEASE SUBMIT TWO COPIES OF A COMPLETE
 LANDSCAPE PLAN WITH A COST ESTIMATE THAT INCLUDES THE
 TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN
 DOWN INTO UNIT COST. PROVIDE THE TABULATION NECESSARY
 FOR THE EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS, INCLUDING
 THE XERISCAPE DESIGN OPTIONS..
  
 3. IRRIGATION REQUIRES A SEPARATE PERMIT. PLEASE SUBMIT
 TWO COPIES OF AN IRRIGATION PLAN, SHOWING THE LAYOUT
 AND COMPONENTS OF THE SYSTEM. THE IRRIGATION SYSTEM
 SHALL PROVIDE 120% COVERAGE TO ALL LANDSCAPE AREAS,
 INCLUDING THE RIGHT-OF-WAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-06-11 Cont ID  
Sent By rkussner Date 2010-06-11 Time 14:41 Rev Time 0.00
Received By rkussner Date 2010-06-11 Time 14:41 Sent To  
Notes
2010-06-11 15:06:40***LANDSCAPE REVIEW FAILED***
  
 RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 2. LANDSCAPING REQUIRES A SEPARATE PERMIT. PLEASE
 SUBMIT TWO COPIES OF A COMPLETE LANDSCAPE PLAN WITH A
 COST ESTIMATE THAT INCLUDES THE TOTAL COST OF ALL
 LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO UNIT
 COST. PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 3. PURSUANT TO SECTION 94-448 (D), PLEASE INCLUDE ALL
 OF THE ITEMS ENUMERATED IN THIS SECTION ON THE
 LANDSCAPE PLAN.
  
 4. IRRIGATION REQUIRES A SEPARATE PERMIT. PLEASE SUBMIT
 TWO COPIES OF AN IRRIGATION PLAN, SHOWING THE LAYOUT
 AND COMPONENTS OF THE SYTEM. THE IRRIGATION SYSTEM
 SHALL PROVIDE 120% COVERGE TO ALL LANDSCAPE AREAS,
 INCLUDING THE RIGHT-OF-WAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop P PLUMBING
Rev No 1 Status P Date 2010-06-23 Cont ID  
Sent By jgomez Date 2010-06-23 Time 14:16 Rev Time 0.00
Received By jgomez Date 2010-06-23 Time 14:16 Sent To  
Notes
2010-06-23 14:27:55PLUMBING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE COMPLETE INFORMATION FOR NEW SPA UNDER A
 SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 3 Status P Date 2010-08-11 Cont ID  
Sent By eschneid Date 2010-08-11 Time 09:29 Rev Time 0.75
Received By eschneid Date 2010-08-11 Time 09:29 Sent To PC
Notes
2010-08-11 09:46:03PASSED W/PROVISO
  
 1) THE INSTALLATION OF THE LANDSCAPE MATERIAL APPROVED
 AS PART OF PERMIT NO. 10070731 AND THE YET UNSUBMITTED
 IRRIGATION PERMIT, SHALL BE INSTALLED AND PASS FINAL
 INSPECTION PRIOR TO THE CONSTRUCTION SERVICES FINAL
 INSPECTION OF THE WORK ON THIS PERMIT.
  
 2) EASEMENT ABANDONMENT APPLICATION SUBMITTED TO
 ENGINEERING SERVICES - ALL UTILITY PROVIDERS HAVE
 SIGNED OFF ON REDUCTION OF EASEMENT WIDTH.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 2 Status F Date 2010-08-02 Cont ID  
Sent By eschneid Date 2010-08-02 Time 13:57 Rev Time 0.50
Received By eschneid Date 2010-08-02 Time 13:57 Sent To  
Notes
2010-08-02 14:30:58FAILED
  
 PLEASE ADDRESS ALL COMMENTS IN WRITING. PLEASE NOTE
 THAT THE CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 1) THE NORTHERN PORTION OF THE PROPOSED LOGGIA IS SHOWN
 WITHIN THE 12 FOOT PUBLIC UTILITY EASEMENT. THE CITY
 DOES NOT PERMIT BUILDINGS MAY BE CONSTRUCTED WITHIN
 UTILITY EASEMENTS.
  
 2) PLEASE NOTE THAT THE FLAGLER PROMENADE PLAT
 PROHIBITS "BUILDINGS, ANY KIND OF CONSTRUCTION OR
 TREES" WITHIN THE EASEMENTS ON THE PLAT. IN ADDITION TO
 THE LOGGIA, THERE IS SPA EQUIPMENT, THE COURTYARD, AND
 OTHER PAVED AREAS SHOWN WITHIN THE 12 FOOT PUBLIC
 UTILITY EASEMENT. PLEASE PROVIDE VERIFICATION THAT THE
 "ANY KIND OF CONSTRUCTION" PORTION OF THIS LANGUAGE NO
 LONGER APPLIES IN ORDER TO CONSTRUCT THE SPA EQUIPMENT,
 THE COURTYARD, AND OTHER AT GRADE PAVED AREAS WITHIN
 THE 12 FOOT PUBLIC UTILITY EASEMENT.
  
 3) AN ENGINEERING SERVICES DEPARTMENT STOP HAS BEEN
 ADDED TO THIS PERMIT REVIEW IN ORDER TO FACILITATE THE
 DISCUSSION REGARDING THE ABANDONMENT OF A PORTION OR
 ALL OF THE EASEMENTS AFFECTING 1 AND 2 ABOVE.
  
 4) NOTE THE INSTALLATION OF THE LANDSCAPE MATERIAL
 APPROVED AS PART OF PERMIT NO. 10070731 AND THE YET
 UNSUBMITTED IRRIGATION PERMIT, SHALL BE INSTALLED AND
 PASS FINAL INSPECTION PRIOR TO THE CONSTRUCTION
 SERVICES FINAL INSPECTION OF THE WORK ON THIS PERMIT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2010-06-16 Cont ID  
Sent By eschneid Date 2010-06-16 Time 12:18 Rev Time 2.50
Received By eschneid Date 2010-06-16 Time 12:18 Sent To  
Notes
2010-06-16 12:27:52FAILED
  
 PLEASE ADDRESS ALL COMMENTS IN WRITING. PLEASE NOTE
 THAT THE CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 1) THE NORTHERN PORTION OF THE PROPOSED LOGGIA IS SHOWN
 WITHIN THE 12 FOOT PUBLIC UTILITY EASEMENT. THE CITY
 DOES NOT PERMIT BUILDINGS MAY BE CONSTRUCTED WITHIN
 UTILITY EASEMENTS.
  
 2) PLEASE NOTE THAT THE FLAGLER PROMENADE PLAT
 PROHIBITS "BUILDINGS, ANY KIND OF CONSTRUCTION OR
 TREES" WITHIN THE EASEMENTS ON THE PLAT. IN ADDITION TO
 THE LOGGIA, THERE IS SPA EQUIPMENT, THE COURTYARD, AND
 OTHER PAVED AREAS SHOWN WITHIN THE 12 FOOT PUBLIC
 UTILITY EASEMENT. PLEASE PROVIDE VERIFICATION THAT THE
 "ANY KIND OF CONSTRUCTION" PORTION OF THIS LANGUAGE NO
 LONGER APPLIES IN ORDER TO CONSTRUCT THE SPA EQUIPMENT,
 THE COURTYARD, AND OTHER AT GRADE PAVED AREAS WITHIN
 THE 12 FOOT PUBLIC UTILITY EASEMENT.
  
 3) IF THE VERIFICATION OUTLINED IN NO. 2 ABOVE IS
 PROVIDED, THEN RELEASES FROM ALL THE UTILITY PROVIDERS,
 FPL, FPU, COMCAST AND BELLSOUTH, AND THE CITY OF WEST
 PALM BEACH SHALL BE PROVIDED IN ORDER TO CONSTRUCT THE
 SPA EQUIPMENT, THE COURTYARD, AND OTHER AT GRADE PAVED
 AREAS WITHIN THE 12 FOOT PUBLIC UTILITY EASEMENT. THE
 FPL LETTER PROVIDED WITH THE APPLICATION WAS ONLY FOR
 THE BUILDING WALL, WHICH MAY NOT BE PLACED WITHIN THE
 EASEMENT.
  
 4) THE SITE PLAN DOES NOT ACCURATELY DEPICT THE NEW
 CONSTRUCTION SHOWN ON SHEET S-1, SPECIFICALLY THE NEW
 CONSTRUCTION WEST OF THE EXTENDED LOGGIA.
  
 5) VERIFY WITH THE CONSTRUCTION SERVICES DEPARTMENT
 THAT THE SPA AND SPA EQUIPMENT DO NOT REQUIRE A
 SEPARATE PERMIT APPLICATION. ADDITIONALLY, PLEASE
 VERIFY WHETHER THE PROPOSED SPA REQUIRES A PROTECTIVE
 BARRIER.
  
 6) THE SPA EQUIPMENT PAD(S) IS SHOWN DIFFERENTLY ON
 SHEETS SP-1, E-1 AND A-1. ALL PLANS SHALL SHOW SAME
 CONDITIONS.
  
 7) PROVIDE THE SETBACK DIMENSION FROM THE ULTIMATE
 CONFIGURATION OF THE SPA EQUIPMENT TO THE NORTH
 PROPERTY LINE. THE EQUIPMENT MAY BE NO CLOSER THAN 6.45
 FEET FROM THE NORTH PROPERTY LINE (4 FEET INTO A
 REQUIRED SETBACK).
  
 8) DESCRIBE HOW THE "FIREWOOD STORAGE" AREA WILL
 FUNCTION. IS IT JUST STACKED FIREWOOD, OR WILL IT BE
 WITHIN A STRUCTURE OR ENCLOSURE? IF IN A STRUCTURE OR
 ENCLOSURE, THEN IT SHALL ADHERE TO THE EASEMENT AND
 REAR SETBACK PROVISIONS OUTLINED IN COMMENTS NO. 2 AND
 7, ABOVE.
  
 9) THE VALUE OF THE CONSTRUCTION ($200,000) EXCEEDS 50%
 OF THE IMPROVEMENT VALUE ($352,838) ACCORDING TO THE
 P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT
 TO SECTION 94-441(C)(2) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN SHALL BE SUBMITTED WITH THE PERMIT. IF
 THE SITE DOES NOT CONFORM TO ARTICLE XIV, THEN A
 SEPARATE LANDSCAPE PERMIT AND IRRIGATION PERMIT SHALL
 BE SUBMITTED TO INSTALL THE MATERIAL TO BRING THE SITE
 INTO CONFORMITY PRIOR TO THE ZONING APPROVAL OF THIS
 PERMIT.
  
 10) SHEET SP-1 REFERS TO A LANDSCAPE PLAN, BUT THERE
 WAS NO COPY OF THE PLAN SUBMITTED WITH THE APPLICATION.
  
 11) THE 2009 AERIAL OF THE PROPERTY SHOWS TREES IN THE
 LOCATION OF THE PROPOSED WORK. TREES MAY ONLY BE
 REMOVED AFTER A TREE ALTERATION PERMIT HAS BEEN ISSUED
 BY THE PLANNING & ZONING DEPARTMENT. PLEASE NOTE THAT
 THE REMOVAL OF TREES (AND SHRUBS) MAY NOT RESULT IN THE
 SITE NOT MEETING THE MINIMUM REQUIREMENTS OUTLINED IN
 THE ZONING AND LAND DEVELOPMENT REGULATIONS.
 ADDITIONALLY, THERE MAY BE NO NET LOSS OF TREE CANOPY.
  
 12) PLEASE VERIFY THAT THE PLANS CALL OUT ALL OF THE
 WORK BEING PERFORMED. THERE APPEAR TO BE FEATURES ON
 SHEET SP-1 THAT ARE NOT CALLED OUT AS NEW WORK, YET DO
 NOT APPEAR ON THE SURVEY.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
  
  
  