Plan Review Stops For Permit 10050795 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-07-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-07-21 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-07-21 |
Time |
11:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-06-21 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-06-21 |
Time |
15:31 |
Sent To |
|
|
Notes |
2010-06-21 16:40:41 | 2007 FBC W/2009 REVISIONS | | ADDITION | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 2) SUBMIT 2 COPIES OF A LOT DRAINAGE PLAN COMPLYING | | WITH FBC R401.3. | | | | 3) ON SHEETS A1 AND A2 THE EXPOSURE CATEGORY IS | | INCORRECTLY SPECIFIED AS B. BECAUSE THE STRUCTURE IS | | LOCATED WITHIN 1500 FEET OF THE INTRA COASTAL WATERWAY | | THE CORRECT EXPOSURE IS CATEGORY C. PLEASE CORRECT THE | | PLANS AND REVISE THE WINDLOAD PRESSURES ACCORDINGLY. | | FBC R 301 | | | | 4) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. CITY | | AMENDMENTS FBC 106.3.3 | | | | 5) PLEASE REVIEW WALL REINFORCEMENT AND BRACING FOR | | GABLE END AT THE CATHEDRAL CEILING. SEE FBC R609.4. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-06-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-06-02 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-06-02 |
Time |
12:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-07-13 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-07-13 |
Time |
11:13 |
Sent To |
|
|
Notes |
2010-07-13 11:14:14 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-06-21 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-06-01 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2010-07-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-07-27 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-07-27 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:41 |
Sent To |
|
|
Notes |
2010-06-21 13:42:26 | IMPACT FEE REVIEW REQUIRED. |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
N |
Date |
2010-07-15 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-07-15 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-07-15 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:59 |
Sent To |
|
|
Notes |
2010-06-21 14:02:40 | MITSUBISHI MINI SPLIT 15000 BTU COOLING & 18000 BTU | | HTG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-06-21 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2010-07-20 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-07-20 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-07-20 |
Time |
09:33 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-06-10 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-06-10 |
Time |
18:54 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-06-10 |
Time |
18:54 |
Sent To |
|
|
Notes |
2010-06-10 18:58:34 | PLANNING AND ZONING: ***** FAILED**** | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. SHOW NEW ADDITION ON SURVEY WITH SETBACK DIMENSIONS | | FROM ALL PROPERTY LINES AND SP-1 | | | | 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO SECTION | | 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 4. PROVIDE TOTAL HEIGHT OF NEW ADDITION TO THE TOP OF | | ROOF LINE. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|