Plan Review Details - Permit 10050688
Plan Review Stops For Permit 10050688
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-08-18 Cont ID  
Sent By jwitmer Date 2010-08-05 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2010-08-05 Time 14:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-06-07 Cont ID  
Sent By jwitmer Date 2010-06-07 Time 15:23 Rev Time 0.77
Received By jwitmer Date 2010-06-07 Time 15:23 Sent To  
Notes
2010-06-07 15:26:26BUILDING PLAN REVIEW
 PERMIT: 09110083/ REV: 10050688
 ADD: 901 N FLAGLER DR, SUITE# 5
 CONT: ANDREA CONSTRUCTION
 TEL: (561)358-4797
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 JUNE 07/ 2010
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET# 2. THE NEW INTERIOR SWING DOORS ARE INDICATED
 AS 2'-8" DOORS, PLEASE REVIEW SEECTION 11-4.13.5,
 DOORWAY MIN CLEAR WIDTH . DOORWAYS SHALL HAVE A MINIMUM
 CLEAR WIDTH OF 32" WITH THE DOOR OPEN 90-DEGREES,
 MEASURED BETWEEN THE FACE OF THE DOOR AND OPPOSITE
 STOP.
  
 3) SHEET # 2. QUESTIONABLE BLUE INK ON PLANS, NOT
 SIGNED BY DEDIGNER OF RECORD NOR DATED, CALLED DESIGN
 PROFESSIONAL AND HE DECLARED HE HAD NOT USED ANY BLUE
 INK ON THE PLANS.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-08-18 Cont ID  
Sent By jleahy Date 2010-08-18 Time 07:09 Rev Time 0.00
Received By jleahy Date 2010-08-18 Time 07:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-06-14 Cont ID  
Sent By btrobaug Date 2010-06-14 Time 12:07 Rev Time 0.00
Received By btrobaug Date 2010-06-14 Time 11:37 Sent To I
Notes
2010-06-14 11:58:40 
  
 REVISION DENIED/INCOMPLETE INFORMATION.
  
 1} HAND DRAWN CHANGES TO THE PLAN ARE NOT ACCEPTABLE
 FOR RECORD RETENTION OR CLARITY IN THE FIELD. 106.1.3
 FBC AS AMENDED. SEE EXAM ROOM#5.
  
 2} 408.4 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION
 EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS***THERE IS NO CIRCUIT FOR
 THE ADDED WATER COOLER.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-08-05 Cont ID  
Sent By lmartine Date 2010-08-05 Time 11:21 Rev Time 0.00
Received By lmartine Date 2010-08-05 Time 11:20 Sent To  
Notes
2010-08-05 11:21:23C-14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-14 Cont ID  
Sent By btrobaug Date 2010-06-14 Time 13:16 Rev Time 0.00
Received By btrobaug Date 2010-05-25 Time 13:11 Sent To PC
Notes
2010-05-25 13:13:46C-16

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-08-10 Cont ID  
Sent By lwagner Date 2010-08-10 Time 09:45 Rev Time 0.00
Received By lwagner Date 2010-08-10 Time 08:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-06-08 Cont ID  
Sent By lwagner Date 2010-06-08 Time 09:17 Rev Time 0.00
Received By lwagner Date 2010-05-27 Time 10:18 Sent To  
Notes
2010-06-08 09:26:43REVISION REVIEW #1
 DENIED
  
 1. DRINKING FOUNTAIN IS NOT SHOWN ON ISOMETRIC.
  
 ****NOTE****
 DRINKING FOUNTAIN IS DRAWN ON PLANS IN INK IN AN EXAM
 ROOM WITH A 2'-8" DOOR. IS THIS NOW AN EXAM ROOM? THE
 DRINKING FOUNTAIN SHOULD BE IN A ROOM WHERE THERE IS
 COMMON ACCESS.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved