Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-05-20 Cont ID  
Sent By jgomez Date 2010-05-20 Time 08:47 Rev Time 0.00
Received By jgomez Date 2010-05-20 Time 08:47 Sent To  
Notes
2010-05-20 08:58:44RESIDENTIAL (R3) ROOF, BUILDING REVIEW CHECKLIST.
  
 1- PERMIT APPLICATION STATES MORE THAN 25% OF ROOF TILE
 TO BE REPLACED. MORE THAN 25% OF ROOF REPLACEMENT
 REQUIRES ENTIRE ROOF TO BE REPLACED AS REQUIRED BY SEC.
 611.1.1 OF 2007 FLORIDA BUILDING CODE-EXISTING
 BUILDING. NEED TO REPLACE ENTIRE ROOF.
  
 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) TILE TO BE INSTALLED.
  
 B) TILE ADHESIVE TO BE USED. SEE TILE PRODUCT APPROVAL
 FOR LISTED ADHESIVES.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER