Plan Review Details - Permit 10050369
Plan Review Stops For Permit 10050369
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-08-31 Cont ID  
Sent By shill Date 2010-08-31 Time 12:28 Rev Time 0.00
Received By shill Date 2010-08-31 Time 12:28 Sent To  
Notes
2010-08-31 12:29:09PROVISO - 4' OF SCREEN AT PROPERTY LINE PER CONTRACTOR
 AND SITE SPECIFIC
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-06-09 Cont ID  
Sent By shill Date 2010-06-09 Time 08:09 Rev Time 0.00
Received By shill Date 2010-06-09 Time 08:09 Sent To  
Notes
2010-06-09 08:33:07****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. FBC R302.1, SEE TABLE R302.1 REGARDING PROJECTIONS,
 WALLS, AND DISTANCE TO THE PROPERTY LINE. A SOLID ROOF
 IS PROPOSED SUPPORTED BY A WALL AT THE PROPERTY LINE;
 THIS DOES NOT COMPLY WITH THE REQUIREMENTS OF FBC R302.
  
 2. PROVIDE THE DIMENSION OF THE WIDTH OF THE WALL, SHOW
 THE WIDTH OF THE WALL LOCATED ON THIS PARCEL, AND SHOW
 HOW THIS IMPROVEMENT (DETAIL SHOWING THAT THE
 ATTACHMENT OF THE PROPOSED SCREEN ENCLOSURE TO THE
 WALL) WILL NOT ENCROACH THE PROPERTY LINE.
  
 3. IT APPEARS THAT THE PROPOSED IMPROVEMENT WILL DRAIN
 ONTO THE ADJACENT PROPERTY, SEE FBC R401.3 AND REVISE
 PLAN TO COMPLIANCE.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-06-09 Cont ID  
Sent By shill Date 2010-06-09 Time 08:33 Rev Time 0.00
Received By shill Date 2010-05-17 Time 11:42 Sent To  
Notes
2010-05-17 11:42:48IN ZONING BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2010-05-19 Cont ID  
Sent By astelly Date 2010-05-19 Time 17:26 Rev Time 0.00
Received By astelly Date 2010-05-19 Time 17:26 Sent To  
Notes
***NONE***