Plan Review Stops For Permit 10040737 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-08-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-08-04 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-08-04 |
Time |
15:32 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-06-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-06-30 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-06-30 |
Time |
17:08 |
Sent To |
|
|
Notes |
2010-06-30 17:18:16 | RESIDENTIAL (R3) REPAIRS/ ADDITION BUILDING REVIEW | | CHECKLIST. | | 2007 FBC WITH 2009 REVISIONS. | | | | 1- A) PER DISCUSSION WITH BUILDING OFFICIAL, CONTRACTOR | | TO PROVIDE SIGNED CONSTRUCTION CONTRACT SHOWING FEE | | BREAKDOWN FOR EACH SCOPE OF WORK TO BE PERFORMED. EG: | | FEES TO RECONSTRUCT EXISTING FLORIDA ROOM AND TO | | REPLACE ROOF AS CITED ON THE HEALTH AND SAFETY | | VIOLATION. AND, FEES FOR THE PROPOSED IMPROVEMENTS | | (REPLACE DOORS, WINDOWS, BATHTUB, ETC.). | | | | ***NOTE: PLEASE MAKE SURE NUMBERS SHOWN ON CONTRACT | | MATCH NUMBERS SHOWN ON PERMIT APPLICATION. | | | | 2- A) PRODUCT APPROVAL FOR STEEL DOOR NOA 08-1015.05 IS | | MISSING THE DRAWINGS. PROVIDE THE DRAWINGS. | | B) CLARIFY IF USING STEEL DOOR NOA 08-0208.07 OR NOT. | | ENGINEER OF RECORD DIDN'T LIST THIS NOA AS PART OF THE | | REVIEWED PRODUCT APPROVALS. | | | | 3- ROOFING PRODUCT APPROVAL NOA 07-0802.09: CLEARLY | | MARK WHICH APPROVED SYSTEM IS GOING TO BE USED TO | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | 4- STORM SHUTTERS: INFORMATION SHOWN ON SHUTTER | | MOUNTING DETAIL ON ENGINEER'S DRAWING #1 DOESN'T MATCH | | INFORMATION SHOWN ON THE SHUTTERS INSTALLATION | | SCHEDULE. COORDINATE INFORMATION TO MATCH. EG: REVISE | | THE DESIGN PRESSURES TO MATCH DESIGN PRESSURES SHOWN ON | | DRAWING #2. REVISE THE MINIMUM EDGE DISTANCE TO MATCH | | ALSO. | | | | 5- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | UP. | | | | 6- ENERGY CALCULATIONS SUBMITTED: | | A) NEED TO PROVIDE CURRENT REVISED FORM. USE FORM | | 1100B-08 NOT 1100B-07. | | B) COMPLETE ALL THE INFORMATION ON TOP OF FORM | | INCLUDING BUILDER AND OWNER INFORMATION. | | C) REVISE ITEM #8. SEE PLANS FOR TOTAL SLAB ON GRADE | | LINEAR FEET. 24 LINEAR FEET IS INCORRECT. | | | | 7- TRUSS PACKAGE SUBMITTED: | | A) TRUSSES NEED TO BE REVISED FOR EXPOSURE "C", NOT | | EXPOSURE "B". REVISE AS REQUIRED. SEE PLANS. | | | | B) TRUSS PACKAGE IS NOT COMPLYING WITH SEC F.A.C. | | CHAPTER 61G15-31.003. MISSING THE TRUSS ENGINEER | | INFORMATION ON EACH SHEET. | | | | C) CLARIFY WHY TRUSS ENGINEER SIGNED AND SEALED | | DOCUMENTS ON 12/13/10? | | | | D) ENGINEER OF RECORD TO REVIEW AND APPROVE TRUSS | | PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-05-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-25 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-25 |
Time |
13:55 |
Sent To |
PC |
|
Notes |
2010-05-25 14:11:10 | RESIDENTIAL (R3) REPAIRS/ADDITION BUILDING REVIEW | | CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- PER DISCUSSION WITH BUILDING OFFICIAL, CONTRACTOR TO | | PROVIDE SIGNED CONSTRUCTION CONTRACT SHOWING FEE | | BREAKDOWN FOR EACH SCOPE OF WORK TO BE PERFORMED. EG: | | FEES TO RECONSTRUCT EXISTING FLORIDA ROOM. FEES TO | | REROOF HOUSE. FEES TO REPLACE DOORS, WINDOWS, BATHTUB, | | ETC. THIS INFORMATION IS REQUIRED TO IDENTIFY | | "SUBSTANTIALLY IMPROVEMENTS" OR "IMPROVEMENTS OF A | | STRUCTURE" TO COMPLY WITH EXISTING HEALTH, SANITARY, OR | | SAFETY CODES WHICH ARE NECESSARY TO ENSURE SAFE LIVING | | CONDITIONS. SEE SUBSTANTIAL IMPROVEMENTS DEFINITION ON | | CITY ORDINANCES SEC. 94-611 TO COMPLY WITH THE CITY | | FLOODPLAIN MANAGEMENT POLICY. | | | | 2- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY | | DCA RULE 9B-72 FOR: | | A) CONCRETE ROOF TILE AND ADHESIVE TO BE USED. IF USING | | SCREWS/NAILS SPECIFY HOW MANY AND TYPE TO VERIFY | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301. | | B) EXTERIOR DOORS TO BE REPLACED. | | C) WINDOWS TO BE REPLACED. | | D) WINDOW MULLIONS. AND CLEARLY MARK SPECIFIC MULLION | | SIZE AND FASTENING TO VERIFY DESIGN PRESSURES OF SEC. | | R301. | | E) STORM SHUTTERS AND COMPLETE INSTALLATION SCHEDULE. | | F) TRUSS CONNECTORS AS SPECIFIED ON PLANS. | | | | 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. | | | | 4- OWES $0.62 FOR RADON FEES FOR NEW PORCH. | | | | 5- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | UP. | | | | 6- PROJECT NOTES ON SHEET 1: | | A) SPECIFY ASCE 7-05 NOT ASCE 7-02. | | B) SPECIFY ROOF DEAD LOADS ALSO AS REQUIRED BY SEC. | | R301.1 OF 2007 FLORIDA RESIDENTIAL CODE. ONLY THE ROOF | | LIVE LOADS WHERE SPECIFIED. | | | | 7- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | N1100.3 OF CHAPTER 11. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2010-05-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-05-07 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-05-07 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2010-07-28 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-07-28 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-07-28 |
Time |
17:53 |
Sent To |
|
|
Notes |
2010-07-28 17:53:44 | GAVE TO JULIO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-07-13 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-07-13 |
Time |
09:09 |
Sent To |
|
|
Notes |
2010-07-13 09:09:29 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-06-17 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-06-17 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-17 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-05-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-25 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-04 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2010-07-13 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-07-13 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-07-13 |
Time |
11:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2010-06-25 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2010-06-25 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2010-06-25 |
Time |
16:17 |
Sent To |
|
|
Notes |
2010-06-25 16:47:49 | ***LANDSCAPE REVIEW FAILED*** | | | | PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT. | | | | 1.PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDR. | | | | 2. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | THE ZLDR. ALL EXISTING AND PROPOSED TREES AND PLANT | | MATERIAL SHALL BE IDENTIFIED BY NAME, SIZE, SPACING AND | | QUANTITY. | | | | 3. PROVIDE THE TABULATION NECESSARY FOR THE EVALUATION | | OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS, INCLUDING THE XERISCAPE DESIGN | | OPTIONS. | | | | 4. PURSUANT TO SECTION 94-448 (D), ALL ITEMS ENUMERATED | | IN THIS SECTION SHALL BE PART OF THE LANDSCAPE PLAN. | | | | 5. IF THE EXISTING LANDSCAPING DOES NOT MEET THE | | MINIMUM REQUIREMENTS AND NEW PLANT MATERIAL IS | | REQUIRED, A SEPARATE LANDCAPE PERMIT SHALL BE | | SUBMITTED. | | | | 6. PURSUANT TO SECTION 94-445 (4) (G) (3) (II), IN ALL | | AREAS THAT ARE TO BE PLANTED IN A CULTIVATED LANDSCAPE, | | IRRIGATION SYSTEMS SHALL BE DESIGNED TO HAVE 120 | | PERCENT COVERAGE, INCLUDING RIGHTS-OF-WAY. A BACKFLOW | | PREVENTER AND RAIN SENSOR IS REQUIRED. PLEASE APPLY FOR | | THE IRRIGATION PERMIT IF AN IRRIGATION SYSTEM DOES NOT | | EXIST OR IF THE EXISTING SYSTEM NEEDS TO BE UPGRADED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462. | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-07-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-07-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-07-01 |
Time |
09:51 |
Sent To |
|
|
Notes |
2010-07-01 09:52:08 | NEED MECHANICAL CONTRACTOR TO APPLY FOR MECHANICAL | | PERMIT. PERMIT APPLICATION HAS NOT CONTRACTOR SIGNED | | FOR THE MECHANICAL WORK. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-08-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-08-04 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-08-04 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2010-05-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2010-05-20 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2010-05-20 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2010-06-23 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-06-23 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-06-23 |
Time |
13:52 |
Sent To |
|
|
Notes |
2010-06-23 13:55:41 | FURTHER REVIEW BY ZONING IS NOT REQUIRED. THE PROPOSED | | EXPANSION HAS BEEN REMOVED FROM THE SCOPE OF WORK AND | | THE LANDSCAPING WILL BE REVIEWED BY THE LANDSCAPE | | PLANNER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-05-10 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2010-05-10 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2010-05-10 |
Time |
09:48 |
Sent To |
|
|
Notes |
2010-05-10 10:01:29 | ***FAILED*** | | | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE PROPERTY. | | IDEALLY, IT SHOULD BE LESS THAN ONE YEAR OLD. | | | | 2. PURSUANT TO SEC. 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS, PLEASE PROVIDE A LANDSCAPE | | PLAN SHOWING HOW THE SUBJECT PROPERTY COMPLIES WITH THE | | LANDSCAPE STANDARDS FOR SINGLE FAMILY DEVELOPMENT (SEC. | | 94-442(B)(2)). BECAUSE THE PROPOSED IMPROVEMENTS EXCEED | | 50 PERCENT OF THE VALUE OF THE IMPROVEMENTS ON THE | | PROPERTY, LANDSCAPE COMPLIANCE IS REQUIRED. THE | | LANDSCAPE PLAN DOES NOT NEED TO BE SIGNED AND SEALED BY | | A LANDSCAPE ARCHITECT. | | | | PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT | | 561-822-1458 OR [email protected] WITH QUESTIONS. | | LANDSCAPE-RELATED QUESTIONS MAY BE DIRECTED TO ROBERT | | KUSSNER, LANDSCAPE PLANNER, WHO MAY BE REACHED AT | | 561-822-1462 OR [email protected]. | | | | |
|
|