Plan Review Details - Permit 10040490
Plan Review Stops For Permit 10040490 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2010-06-16 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-06-16 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-06-16 |
Time |
13:09 |
Sent To |
|
|
Notes |
2010-06-16 14:15:58 | *****APPROVED**** | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | ADDRESSED. THE FIRE ALARM PLAN (FA-1 AND FA-1) WAS | | FIRE-STAMPED ACCORDINGLY; READY FOR PERMIT ISSUANCE. | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2010-05-10 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-05-07 |
Time |
14:25 |
Sent To |
|
|
Notes |
2010-05-10 20:41:49 | *****DENIED***** | | | | | | 1. THE SPECIFICATIONS PACKAGE INCLUDES INFORMATION FOR | | SINGLE-ENDED REFLECTED TYPE BEAM SMOKE DETECTORS | | INSTEAD OF HEAT DETECTORS AS LISTED IN THE FIRE ALARM | | PLAN. | | | | 2. ON SHEET FA-2, THE FLOOR PLAN / FIRE ALARM SYSTEM | | LAYOUT IS TOO SMALL. ENLARGE THE DRAWING TO CLEARLY AND | | DISTINCTLY SHOW/LIST THE DEVICES AND THEIR | | CORRESPONDING ADDRESSES. | | | | 3. THE PLAN INDICATES THAT SMOKE DETECTORS ARE | | INSTALLED IN THE SLEEPING ROOMS. PLEASE FAMILIARIZE | | YOURSELF AND BE ADVISED OF THE SMOKE ALARM REQUIREMENTS | | AS PER 32.2.3.4.3 OF 2006 NFPA 101 - LIFE SAFETY CODE - | | FLORIDA 2007 EDITION. ATTENTION: IN LIEU OF SMOKE | | ALARMS, FIRE ALARM SYSTEM SMOKE DETECTORS IN ACCORDANCE | | WITH NFPA 72 SHALL BE PERMITTED IF SO ARRANGED TO | | FUNCTION IN THE SAME MANNER AS SMOKE ALARMS. | | | | 4. IN NEW CONSTRUCTION AND/OR CONVERSIONS, WHERE TWO OR | | MORE ALARMS ARE INSTALLED WITHIN A DWELLING UNIT, SUITE | | OF ROOMS, OR SIMILAR AREA, SHALL BE ARRANGED SO THAT | | THE OPERATION OF ANY SMOKE ALARM SHALL CAUSE ALL ALARMS | | WITHIN THESE LOCATIONS TO SOUND. SMOKE ALARMS SHALL | | RECEIVE THEIR OPERATING POWER FROM THE BUILDING | | ELECTRICAL SYSTEM. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-06-08 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-06-08 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-08 |
Time |
08:20 |
Sent To |
|
|
Notes |
2010-06-08 08:21:07 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-05-07 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-05-10 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-04-21 |
Time |
11:53 |
Sent To |
|
|
Notes |
2010-04-21 11:53:23 | *****ROUTED TO FIRE BOX***** |
|
|
|