Plan Review Details - Permit 10040384
Plan Review Stops For Permit 10040384 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2010-05-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-26 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-26 |
Time |
13:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2010-05-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-26 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-26 |
Time |
12:37 |
Sent To |
|
|
Notes |
2010-05-26 12:59:28 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW SECOND | | CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- ROOF CALCULATIONS SUBMITTED: | | | | A) ENGINEER TO PROVIDE ACTUAL RAS 117 CALCULATIONS. | | FASTENING OPTION #1 ON PAGE 5 OF NOA 08-0924.14 | | SUBMITTED IS GOOD ONLY FOR -60PSF. IT CAN'T BE USED FOR | | ALL ROOF ZONES AS SPECIFIED BY THE ENGINEER. PERIMETER | | AND CORNER AREAS REQUIRE HIGHER DESIGN PRESSURES. | | | | B) PROVIDE ACTUAL CALCULATIONS FOR COMPONENTS AND | | CLADDING. INFORMATION SUBMITTED IS INCORRECT. | | CALCULATED DESIGN PRESSURES ARE NOT FOR EXPOSURE "C". | | REVISE AS REQUIRED. | | | | C) CURRENT CODE IS THE 2007 FLORIDA RESIDENTIAL CODE | | WITH 2009 REVISIONS. ENGINEER TO REFER TO ASCE 7-05 NOT | | ASCE 7-02. | | | | D) ENGINEER TO PROVIDE ALL HIS INFORMATION AS REQUIRED | | BY CHAPTER 471 FLORIDA STATUTE AND FLORIDA | | ADMINISTRATIVE CODE SEC. 61G15-23.002(2). MISSING THE | | ENGINEER'S ADDRESS. | | | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2010-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-04-19 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-04-19 |
Time |
10:15 |
Sent To |
|
|
Notes |
2010-04-19 10:31:30 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS ( 2 | | COPIES) AS REQUIRED BY GENERAL LIMITATION #7 ON LAST | | PAGE OF MULE-HIDE PRODUCTS CO. INC NOA 08-0924.14 | | SUBMITTED. | | | | 2- CLARIFY WHICH APPROVED ASSEMBLY IS GOING TO BE | | INSTALLED. IS IT AN INSULATED SYSTEM AS SHOWN ON PAGE 5 | | SUBMITTED. OR IS IT A NON-INSULATED SYSTEM AS SHOWN ON | | PAGE 34 SUBMITTED. | | ***NOTE: NON-INSULATED SYSTEM ON PAGE 34 CAN'T NOT BE | | USED BECAUSE IT DOESN'T MEET THE DESIGN PRESSURES | | REQUIRED BY SEC. 301 OF 2007 FLORIDA RESIDENTIAL CODE. | | AND, GENERAL LIMITATION #9 DOESN'T ALLOW NAIL | | ENHANCING. SEE LAST PAGE OF NOA SUBMITTED. | | | | 3- DESIGN PROFESSIONAL DOING THE RAS 117 CALCULATIONS | | TO TAKE INTO CONSIDERATION THAT THIS BUILDING IS | | LOCATED ON EXPOSURE "C" AS REQUIRED BY SEC. | | R301.2.1.4.3 OF 2009 REVISIONS TO THE 2007 FLORIDA | | RESIDENTIAL CODE. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-04-19 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-04-19 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
|