Plan Review Details - Permit 10040368
Plan Review Stops For Permit 10040368
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-04-21 Cont ID  
Sent By jwitmer Date 2010-04-21 Time 08:04 Rev Time 0.55
Received By jwitmer Date 2010-04-21 Time 08:04 Sent To  
Notes
2010-04-21 08:38:53BUILDING PLAN REVIEW
 PERMIT:09120266 /REV 10040368
 ADD: 400 N FLAGLER
 CONT: ROBB CONSTRUCTION
  
 TEL: (561)856-1643
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS AND FEES.
  
 NOTE THE NEW TENANT SEPARATION SECTION OF WALL MAY
 REQUIRE A REVISION FOR MECHANICAL IF DUCT PENETRATE
 THIS PORTION OF THE TENANT SEPARATION WALL.
  
 708.3 FIRE-RESISTANCE RATING. FIRE PARTITIONS SHALL
 HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR.
 WALL SEPARATING INDIVIDUAL TENANT SPACES.708.1(7).
  
 712.3.3 DUCTS AND AIR TRANSFER OPENINGS. PENETRATIONS
 OF FIRE-RESISTANCE-RATED WALLS BY DUCTS THAT ARE NOT
 PROTECTED WITH DAMPERS SHALL COMPLY WITH SECTIONS 712.2
 THROUGH 712.3.1. DUCTS AND AIR TRANSFER OPENINGS THAT
 ARE PROTECTED WITH DAMPERS SHALL COMPLY WITH SECTION
 716.
  
 716.3.1 FIRE PROTECTION RATING. FIRE DAMPERS SHALL HAVE
 THE MINIMUM FIRE PROTECTION RATING SPECIFIED IN TABLE
 716.3.1 FOR THE TYPE OF PENETRATION.
  
 TABLE 716.3.1 FIRE DAMPER RATING
  
 TYPE OF PENETRATION MINIMUM DAMPER RATING
 (HOURS)
 LESS THAN 3-HOUR FIRE-RESISTANCE-RATED ASSEMBLIES 1.5
  
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-04-20 Cont ID  
Sent By mawillia Date 2010-04-20 Time 14:34 Rev Time 0.00
Received By mawillia Date 2010-04-20 Time 14:06 Sent To  
Notes
2010-04-20 14:07:10*****R3EVISION #2, DATED 03/08/10, APPROVED*****
  
  
 REVISED PLAN SHEETS LS.1, A1.2, AND A2.1 WERE STAMPED,
 INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***