|
 |
 |
 |
 |
 |
Plan Review Details - Permit 10040347
Plan Review Stops For Permit 10040347 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-04-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-04-21 |
Time |
09:43 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2010-04-21 |
Time |
09:35 |
Sent To |
|
|
Notes |
2010-04-21 09:42:53 | BUILDING PLAN REVIEW | | PERMIT: 10040347 | | ADD: 1801 S FLAGLER DR #1203 | | CONT: MARYJUII CONSTRUCTION | | TEL: (561)386-6032 | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | | PLANS INDICATE THE DELETION OF FLOORING AND NEW MEXICAN | | TILE FLOOR INSTALLATION, PLEASE REVIEW FLOOR INSULATION | | REQUIREMENT. | | | | 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES | | BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A | | PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE | | AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS | | THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE | | WITH ASTM E 492. | | | | JIM WITMER C. B. O. | | COMMERCIAL COMBINATION PLAN REVIEW | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | CUSTOMER SERVICE SURVEY AT: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-05-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-05-18 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-05-18 |
Time |
10:46 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-04-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-22 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-22 |
Time |
10:06 |
Sent To |
|
|
Notes |
2010-04-22 10:33:06 | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2 | | RESIDENTIAL FLORIDA BUILDING CODE. INDICATE LOCATIONS | | ON PLAN. | | | | 2} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. LOCATE ON | | THE PLANS. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2010-04-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-04-20 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-04-20 |
Time |
14:40 |
Sent To |
|
|
Notes |
2010-04-20 14:58:06 | *****PROVISO***** | | | | PLAN SHEET 1 (OF 1) STAMPED, INITIALED, AND DATED WITH | | THE FOLLOWING ATTACHED PROVISIONS: | | | | * THE 2007 FLORIDA FIRE PREVENTION CODE BASED ON NFPA | | 101, LIFE SAFETY CODE, 2006 EDITION AND NFPA 1, UNIFORM | | FIRE CODE, 2006 EDITION SHALL BE REFERENCED. | | * THE INTERIOR FINISH MATERIAL FOR THE NEW WALLS AND | | CEILINGS SHALL BE CLASS A, CLASS B, OR CLASS C. | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-05-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-13 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2010-04-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-04-21 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2010-04-21 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2010-05-11 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2010-05-11 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2010-05-11 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2010-04-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2010-04-15 |
Time |
17:13 |
Rev Time |
0.15 |
Received By |
eschneid |
Date |
2010-04-15 |
Time |
17:13 |
Sent To |
|
|
Notes |
2010-04-15 17:14:03 | VALUE OF WORK LESS THAN 50% OF UNIT VALUE. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |