Plan Review Details - Permit 10040320
Plan Review Stops For Permit 10040320
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-06-17 Cont ID  
Sent By jwitmer Date 2010-06-17 Time 14:08 Rev Time 3.33
Received By jwitmer Date 2010-06-17 Time 14:08 Sent To  
Notes
2010-06-17 14:09:22MASTER PLAN: 10040320
  
  
 BLDG TYPE/ADDRESS
  
 I 1901 SPRUCE AVE
 I 2208 A E ISAACS AVE
 A 609 22ND ST
 E 527 22ND ST
 E 529 21ST ST
 E 545 21ST ST
 F 511 22ND ST
 F 519 22ND ST
 F 535 22ND ST
 F 543 22ND ST
 F 550 21ST ST
 F 615 22ND ST
 F 2115 DIVISION AVE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2010-05-04 Cont ID  
Sent By jwitmer Date 2010-05-04 Time 10:04 Rev Time 2.50
Received By jwitmer Date 2010-05-04 Time 07:53 Sent To  
Notes
2010-05-04 10:05:26BLDG TYPE: F
 SHEETS REVIEWED:
 A0.1
 A4.1
 A4.2
 A5.1
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-06-09 Cont ID  
Sent By btrobaug Date 2010-06-09 Time 11:11 Rev Time 0.00
Received By btrobaug Date 2010-06-09 Time 10:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-04-28 Cont ID  
Sent By btrobaug Date 2010-04-28 Time 15:11 Rev Time 0.00
Received By btrobaug Date 2010-04-28 Time 10:53 Sent To  
Notes
2010-04-28 13:59:33 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE POWER PLAN NOTES (ALL UNITS) SHOULD INCLUDE
 NOTING " 406.11 TAMPER-RESISTANT RECEPTACLES IN
 DWELLING UNITS.IN ALL AREAS SPECIFIED IN 210.52, ALL
 125-VOLT, 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED
 TAMPER-RESISTANT RECEPTACLES".TO AVOID CONFUSION IN THE
 FIELD.
  
 2} ALL RISER DIAGRAMS SHALL INDICATE COMPLIANCE WITH
 250.94: REVISED TO PROVIDE THE SPECIFIC MEANS FOR
 INTERSYSTEM BONDING CONNECTIONS AND TO PROHIBIT BONDING
 MEANS ATTACHED TO AN ENCLOSURE FROM INTERFERING WITH
 OPENING OR REMOVAL OF THE ENCLOSURE COVER.
  
 3} 210.52(B)(3) KITCHEN RECEPTACLE REQUIREMENTS.
 RECEPTACLES INSTALLED IN A KITCHEN TO SERVE COUNTERTOP
 SURFACES SHALL BE SUPPLIED BY NOT FEWER THAN TWO
 SMALL-APPLIANCE BRANCH CIRCUITS, EITHER OR BOTH OF
 WHICH SHALL ALSO BE PERMITTED TO SUPPLY RECEPTACLE
 OUTLETS IN THE SAME KITCHEN AND IN OTHER ROOMS
 SPECIFIED IN 210.52(B)(1). ADDITIONAL SMALL-APPLIANCE
 BRANCH CIRCUITS SHALL BE PERMITTED TO SUPPLY RECEPTACLE
 OUTLETS IN THE KITCHEN AND OTHER ROOMS SPECIFIED IN
 210.52(B)(1).***ALL UNITSONLY HAVE ONE CIRCUIT IN THE
 KITCHEN.
  
 4} 210.52 (C) COUNTERTOPS. IN KITCHENS, PANTRIES,
 BREAKFAST ROOMS, DINING ROOMS, AND SIMILAR AREAS OF
 DWELLING UNITS, RECEPTACLE OUTLETS FOR COUNTERTOP
 SPACES SHALL BE INSTALLED IN ACCORDANCE WITH
 210.52(C)(1) THROUGH (C)(5).210.52 (C)(1) WALL
 COUNTERTOP SPACES. A RECEPTACLE OUTLET SHALL BE
 INSTALLED AT EACH WALL COUNTERTOP SPACE THAT IS 300 MM
 (12 IN.) OR WIDER. RECEPTACLE OUTLETS SHALL BE
 INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE
 THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM A
 RECEPTACLE OUTLET IN THAT SPACE.*** SEE UNITS A,E & F.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2010-05-11 Cont ID  
Sent By mawillia Date 2010-05-11 Time 15:48 Rev Time 0.00
Received By mawillia Date 2010-05-11 Time 14:39 Sent To  
Notes
2010-05-11 15:42:17*****APPROVED*****
  
  
 PLAN SHEETS A4.2, A5.1, AND E4.1 WERE STAMPED,
 INITIALED, AND DATED

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2010-06-03 Cont ID  
Sent By lwagner Date 2010-06-03 Time 13:02 Rev Time 0.00
Received By lwagner Date 2010-06-03 Time 13:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-05-27 Cont ID  
Sent By vmolina Date 2010-05-27 Time 12:08 Rev Time 0.00
Received By vmolina Date 2010-05-27 Time 12:08 Sent To  
Notes
2010-05-27 12:12:25B-15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-05-21 Cont ID  
Sent By lmartine Date 2010-05-20 Time 12:50 Rev Time 0.00
Received By lmartine Date 2010-04-13 Time 10:30 Sent To  
Notes
2010-04-14 10:30:34I-30

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-06-03 Cont ID  
Sent By lwagner Date 2010-06-03 Time 13:01 Rev Time 0.00
Received By lwagner Date 2010-06-03 Time 12:47 Sent To G
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-04-19 Cont ID  
Sent By lwagner Date 2010-04-19 Time 13:40 Rev Time 0.00
Received By lwagner Date 2010-04-19 Time 10:58 Sent To  
Notes
2010-04-19 13:40:33FBC 2007
 REVIEW: DENIED
  
 SHEET P6.1
 IF THIS IS AN INDIVIDUALLY VENTED SYSTEM THEN THESE
 VENTS THAT ARE SHOWN ON THE MAIN NEED TO BE ON THE
 BRANCH OFF OF THE MAIN.
 1. SAN RISER "E" - SH-1 IN BATHROOM 115 REQUIRES A VENT
 ON THE BRANCH.
 2. SAN RISER "F" - WC-1 IN BATHROOM 207 REQUIRES A VENT
 ON THE BRANCH.
 SH-1 IN BATHROOM 217 REQUIRES A VENT ON THE BRANCH.
 WC-1 & SH-1 IN BATHROOM 117 REQUIRE A VENT ON THE
 BRANCHS.
 3. SAN RISER "I" WC-1 & SH-1WOULD REQUIRE VENTS ON THE
 BRANCHES AS KITCHEN SINKS ARE NOT PERMITTED ON WET
 VENTS FBC 2007 PLUMBING 909.1
 4. SAN RISER "A" WC-1 & SH-1 IN BATHROOM 119 REQUIRE A
 VENT ON THE BRANCHS.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 (561) 805-6692
 FAX (561) 653-2692
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2010-06-15 Cont ID  
Sent By ajones Date 2010-06-15 Time 14:45 Rev Time 0.00
Received By ajones Date 2010-06-15 Time 14:44 Sent To  
Notes
2010-06-15 14:46:07PASSED WITH THE PROVISO THAT A LANDSCAPE PERMIT BE
 APPLIED FOR AND ISSUED PRIOR TO A BUILDING FINAL.

Review Stop Z ZONING
Rev No 2 Status F Date 2010-06-10 Cont ID  
Sent By lfranco Date 2010-06-10 Time 16:28 Rev Time 0.00
Received By lfranco Date 2010-06-10 Time 16:28 Sent To L
Notes
2010-06-10 16:32:42PLANNING AND ZONING: **** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE
 REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT FOR A SEPARATE LANDSCAPE PERMIT
 (REFERENCE THIS MASTER PERMIT) THAT INCLUDES TWO (2)
 COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE WITH
 SECTIONS 94-442 AND 94-445 OF THE ZLDR AND ANY
 ADDITIONAL INFORMATION REQUIRED BY ROBERT KUSSNER
 (LANDSCAPE PLANNER (561) 822-1462.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2010-05-20 Cont ID  
Sent By lfranco Date 2010-05-20 Time 21:11 Rev Time 0.00
Received By lfranco Date 2010-05-20 Time 21:11 Sent To  
Notes
2010-05-20 21:16:10PLANNING AND ZONING: **** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. THE VALUE OF PROPOSED WORK WAS NOT PROVIDED,
 THEREFORE, IT CAN NOT BE DETERMINED IF THE INTERIOR
 WORK DOES OR DOES NOT EXCEED 50% OF THE IMPROVEMENT
 VALUE TO REQUIRE LANDSCAPING UPGRADES.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]
  