Plan Review Stops For Permit 10040320 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2010-06-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-06-17 |
Time |
14:08 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2010-06-17 |
Time |
14:08 |
Sent To |
|
|
Notes |
2010-06-17 14:09:22 | MASTER PLAN: 10040320 | | | | | | BLDG TYPE/ADDRESS | | | | I 1901 SPRUCE AVE | | I 2208 A E ISAACS AVE | | A 609 22ND ST | | E 527 22ND ST | | E 529 21ST ST | | E 545 21ST ST | | F 511 22ND ST | | F 519 22ND ST | | F 535 22ND ST | | F 543 22ND ST | | F 550 21ST ST | | F 615 22ND ST | | F 2115 DIVISION AVE. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2010-05-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2010-05-04 |
Time |
10:04 |
Rev Time |
2.50 |
Received By |
jwitmer |
Date |
2010-05-04 |
Time |
07:53 |
Sent To |
|
|
Notes |
2010-05-04 10:05:26 | BLDG TYPE: F | | SHEETS REVIEWED: | | A0.1 | | A4.1 | | A4.2 | | A5.1 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2010-06-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-06-09 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-06-09 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2010-04-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2010-04-28 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2010-04-28 |
Time |
10:53 |
Sent To |
|
|
Notes |
2010-04-28 13:59:33 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | REVISIONS, 2008 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} THE POWER PLAN NOTES (ALL UNITS) SHOULD INCLUDE | | NOTING " 406.11 TAMPER-RESISTANT RECEPTACLES IN | | DWELLING UNITS.IN ALL AREAS SPECIFIED IN 210.52, ALL | | 125-VOLT, 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | TAMPER-RESISTANT RECEPTACLES".TO AVOID CONFUSION IN THE | | FIELD. | | | | 2} ALL RISER DIAGRAMS SHALL INDICATE COMPLIANCE WITH | | 250.94: REVISED TO PROVIDE THE SPECIFIC MEANS FOR | | INTERSYSTEM BONDING CONNECTIONS AND TO PROHIBIT BONDING | | MEANS ATTACHED TO AN ENCLOSURE FROM INTERFERING WITH | | OPENING OR REMOVAL OF THE ENCLOSURE COVER. | | | | 3} 210.52(B)(3) KITCHEN RECEPTACLE REQUIREMENTS. | | RECEPTACLES INSTALLED IN A KITCHEN TO SERVE COUNTERTOP | | SURFACES SHALL BE SUPPLIED BY NOT FEWER THAN TWO | | SMALL-APPLIANCE BRANCH CIRCUITS, EITHER OR BOTH OF | | WHICH SHALL ALSO BE PERMITTED TO SUPPLY RECEPTACLE | | OUTLETS IN THE SAME KITCHEN AND IN OTHER ROOMS | | SPECIFIED IN 210.52(B)(1). ADDITIONAL SMALL-APPLIANCE | | BRANCH CIRCUITS SHALL BE PERMITTED TO SUPPLY RECEPTACLE | | OUTLETS IN THE KITCHEN AND OTHER ROOMS SPECIFIED IN | | 210.52(B)(1).***ALL UNITSONLY HAVE ONE CIRCUIT IN THE | | KITCHEN. | | | | 4} 210.52 (C) COUNTERTOPS. IN KITCHENS, PANTRIES, | | BREAKFAST ROOMS, DINING ROOMS, AND SIMILAR AREAS OF | | DWELLING UNITS, RECEPTACLE OUTLETS FOR COUNTERTOP | | SPACES SHALL BE INSTALLED IN ACCORDANCE WITH | | 210.52(C)(1) THROUGH (C)(5).210.52 (C)(1) WALL | | COUNTERTOP SPACES. A RECEPTACLE OUTLET SHALL BE | | INSTALLED AT EACH WALL COUNTERTOP SPACE THAT IS 300 MM | | (12 IN.) OR WIDER. RECEPTACLE OUTLETS SHALL BE | | INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE | | THAN 600 MM (24 IN.) MEASURED HORIZONTALLY FROM A | | RECEPTACLE OUTLET IN THAT SPACE.*** SEE UNITS A,E & F. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2010-05-11 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2010-05-11 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-05-11 |
Time |
14:39 |
Sent To |
|
|
Notes |
2010-05-11 15:42:17 | *****APPROVED***** | | | | | | PLAN SHEETS A4.2, A5.1, AND E4.1 WERE STAMPED, | | INITIALED, AND DATED |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2010-06-03 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-06-03 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-06-03 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-05-27 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-05-27 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-05-27 |
Time |
12:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2010-05-21 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2010-05-20 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2010-04-13 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2010-06-03 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-06-03 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-06-03 |
Time |
12:47 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2010-04-19 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2010-04-19 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2010-04-19 |
Time |
10:58 |
Sent To |
|
|
Notes |
2010-04-19 13:40:33 | FBC 2007 | | REVIEW: DENIED | | | | SHEET P6.1 | | IF THIS IS AN INDIVIDUALLY VENTED SYSTEM THEN THESE | | VENTS THAT ARE SHOWN ON THE MAIN NEED TO BE ON THE | | BRANCH OFF OF THE MAIN. | | 1. SAN RISER "E" - SH-1 IN BATHROOM 115 REQUIRES A VENT | | ON THE BRANCH. | | 2. SAN RISER "F" - WC-1 IN BATHROOM 207 REQUIRES A VENT | | ON THE BRANCH. | | SH-1 IN BATHROOM 217 REQUIRES A VENT ON THE BRANCH. | | WC-1 & SH-1 IN BATHROOM 117 REQUIRE A VENT ON THE | | BRANCHS. | | 3. SAN RISER "I" WC-1 & SH-1WOULD REQUIRE VENTS ON THE | | BRANCHES AS KITCHEN SINKS ARE NOT PERMITTED ON WET | | VENTS FBC 2007 PLUMBING 909.1 | | 4. SAN RISER "A" WC-1 & SH-1 IN BATHROOM 119 REQUIRE A | | VENT ON THE BRANCHS. | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2010-06-15 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2010-06-15 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2010-06-15 |
Time |
14:44 |
Sent To |
|
|
Notes |
2010-06-15 14:46:07 | PASSED WITH THE PROVISO THAT A LANDSCAPE PERMIT BE | | APPLIED FOR AND ISSUED PRIOR TO A BUILDING FINAL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2010-06-10 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-06-10 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-06-10 |
Time |
16:28 |
Sent To |
L |
|
Notes |
2010-06-10 16:32:42 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. THE SUBMITTAL OF THE | | REQUESTED INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | THE ZLDR. | | | | PLEASE SUBMIT FOR A SEPARATE LANDSCAPE PERMIT | | (REFERENCE THIS MASTER PERMIT) THAT INCLUDES TWO (2) | | COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE WITH | | SECTIONS 94-442 AND 94-445 OF THE ZLDR AND ANY | | ADDITIONAL INFORMATION REQUIRED BY ROBERT KUSSNER | | (LANDSCAPE PLANNER (561) 822-1462. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2010-05-20 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2010-05-20 |
Time |
21:11 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2010-05-20 |
Time |
21:11 |
Sent To |
|
|
Notes |
2010-05-20 21:16:10 | PLANNING AND ZONING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. THE VALUE OF PROPOSED WORK WAS NOT PROVIDED, | | THEREFORE, IT CAN NOT BE DETERMINED IF THE INTERIOR | | WORK DOES OR DOES NOT EXCEED 50% OF THE IMPROVEMENT | | VALUE TO REQUIRE LANDSCAPING UPGRADES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|