Plan Review Details - Permit 10040222
Plan Review Stops For Permit 10040222 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2010-06-11 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-06-11 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-06-11 |
Time |
10:06 |
Sent To |
|
|
Notes |
2010-06-11 10:28:54 | *****APPROVED***** | | | | DRAWING FP-1, HYDRAULIC CALCULATION AND CUTSHEETS WERE | | STAMPED, DATED AND APPROVED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2010-05-07 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2010-05-07 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2010-05-07 |
Time |
08:45 |
Sent To |
|
|
Notes |
2010-05-07 09:03:14 | *****UNSAT***** | | | | 1) STANDARD SPRAY SPRINKLERS IN OPEN OFFICE AREA SPACED | | GREATER THAN 15'-0" APART. | | | | 2) PROVIDE MINIMUM PUMP SUCTION PRESSURE OF 20 PSI | | (HYDRAULIC CALCULATIONS). | | | | 3) HYDRAULIC CALCULATION BRANCH LINE LENGTH NOT PER | | NFPA. | | NODES 107 AND 102 ARE BEYOND THE 36' BRANCH LINE LENGTH | | AND SHOULD NOT BE CALCULATED. | | REVISE CALCULATED AREA EXCLUDING NODES 107 AND 102. | | | | | | WESLEY JOLIN | | FIRE PROTECTION ENGINEER | | 561.805.6730 | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561.805.6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2010-04-16 |
Time |
17:55 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2010-04-16 |
Time |
17:25 |
Sent To |
|
|
Notes |
2010-04-18 21:03:54 | *****UNSAT***** | | | | | | 1. THE CALCULATED BRANCH LINE WIDTH OF 28 FEET IS NOT | | PER NFPA GUIDELINES. A REMOTE AREA OF 900 SQUARE FEET | | CORRESPONDS TO A BRANCH LINE CALCULATION OF 36 FEET. | | | | 2. LEFT SIDE OF CROSS MAIN (3 TOTAL SPRINKLERS) APPEARS | | TO BE MORE DEMANDING THAN SUBMITTED CALCULATION OF TWO | | SPRINKLERS ON BRANCH LINES. | | | | 3. VERIFY THAT PENETRATIONS OF THE NEW 2-HOUR RATED | | FIRE WALL ARE SEALED. | | | | | | WESLEY JOLIN | | FIRE PROTECTION ENGINEER | | 561-805-6730 | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2010-06-10 |
|
|
Cont ID |
|
Sent By |
vmolina |
Date |
2010-06-10 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
vmolina |
Date |
2010-06-10 |
Time |
08:49 |
Sent To |
|
|
Notes |
2010-06-10 08:49:24 | IN FIRE BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2010-05-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2010-05-04 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-05-04 |
Time |
11:15 |
Sent To |
FIRE |
|
Notes |
2010-05-04 11:16:37 | SENT TO FIRE BOX. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2010-04-19 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2010-04-12 |
Time |
16:00 |
Sent To |
|
|
Notes |
2010-04-12 16:00:36 | SENT TO FIRE BOX. |
|
|
|